Validity and reliability of physical activity measures in multiple sclerosis

被引:7
作者
Anens, Elisabeth [1 ]
Ahlstrom, Isabell [1 ]
Emtner, Margareta [1 ]
Zetterberg, Lena [1 ]
Nilsagard, Ylva [2 ,3 ]
Hellstrom, Karin [1 ]
机构
[1] Dept Neurosci, Sect Physiotherapy, Uppsala, Sweden
[2] Orebro Univ, Fac Med & Hlth, Dept Hlth Care Sci, Orebro, Sweden
[3] Univ Res Hlth Care Ctr, Reg Orebro Cty, Orebro, Sweden
关键词
Exercise; multiple sclerosis; physical activity; reproducibility of results; validation studies; IMPACT SCALE MSIS-29; SC-STEPMX PEDOMETER; DISABILITY SURVEY; WALKING ABILITY; PEOPLE; ACCELEROMETER; ACTIGRAPH; ACCURACY; EXERCISE; ADULTS;
D O I
10.1080/09593985.2021.1996498
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose The purpose was to evaluate the psychometric properties of physical activity measures in persons with multiple sclerosis (PwMS). Methods Adults with multiple sclerosis were recruited, n = 30 (validation) and n = 57 (test-retest). Steps measured with PiezoRX, Yamax SW200 and ActiGraph GT9X Link (AGlink) and time in different positions measured with AGlink were validated against data from video analysis. Psychometric properties of the Physical Activity and Disability Survey - Revised Swedish version (PADS-R(Sw)) was evaluated. Results The most valid measures were AGlink using the low-frequency extension filter, and PiezoRX with median absolute percentage errors (MeAPEs) of 0.9-3.1% and 1.3-3.3%. The MeAPEs were higher for Yamax SW200 (2.9-21.0%), AGlink display (3.6-44.8%) and AGlink normal filter (8.9-48.9%), indicating low validity. AGlink was not valid in measurements of sitting (MeAPE 12.0-12.5%) or lying (MeAPE 31.0-41.7%). The correlation between PADS-R(Sw) and AGlink steps was r = 0.492 (p = .009). The relative reliability of PADS-R(Sw) was ICC2,1 0.85 (CI 0.76-0.91), and absolute reliability was SEM 0.54. Conclusion AGlink and PiezoRX were valid measures of steps in PwMS. The questionnaire PADS-R(Sw) was valid, with high relative reliability, but its absolute reliability was unsatisfactory.
引用
收藏
页码:137 / 153
页数:17
相关论文
共 55 条
[1]   Step-Rate Thresholds for Physical Activity Intensity in Persons With Multiple Sclerosis [J].
Agiovlasitis, Stamatis ;
Motl, Robert W. .
ADAPTED PHYSICAL ACTIVITY QUARTERLY, 2014, 31 (01) :4-18
[2]   Accuracy of inclinometer functions of the activPAL and ActiGraph GT3X+: A focus on physical activity [J].
An, Hyun-Sung ;
Kim, Youngwon ;
Lee, Jung-Min .
GAIT & POSTURE, 2017, 51 :174-180
[3]  
Balto Julia M, 2016, Mult Scler J Exp Transl Clin, V2, p2055217316634754, DOI 10.1177/2055217316634754
[4]   Step Counting: A Review of Measurement Considerations and Health-Related Applications [J].
Bassett, David R., Jr. ;
Toth, Lindsay P. ;
LaMunion, Samuel R. ;
Crouter, Scott E. .
SPORTS MEDICINE, 2017, 47 (07) :1303-1315
[5]   Guidelines for the process of cross-cultural adaptation of self-report measures [J].
Beaton, DE ;
Bombardier, C ;
Guillemin, F ;
Ferraz, MB .
SPINE, 2000, 25 (24) :3186-3191
[6]   Sedentary Time and Its Association With Risk for Disease Incidence, Mortality, and Hospitalization in Adults A Systematic Review and Meta-analysis [J].
Biswas, Aviroop ;
Oh, Paul I. ;
Faulkner, Guy E. ;
Bajaj, Ravi R. ;
Silver, Michael A. ;
Mitchell, Marc S. ;
Alter, David A. .
ANNALS OF INTERNAL MEDICINE, 2015, 162 (02) :123-+
[7]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[8]  
Carter R.E., 2016, Rehabilitation research. Principles and applications, V5th
[9]   Objective physical activity levels in people with multiple sclerosis: Meta-analysis [J].
Casey, B. ;
Coote, S. ;
Galvin, R. ;
Donnelly, A. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2018, 28 (09) :1960-1969
[10]   Validity of the SC-StepMX pedometer during treadmill walking and running [J].
Colley, Rachel C. ;
Barnes, Joel D. ;
Leblanc, Allana G. ;
Borghese, Michael ;
Boyer, Charles ;
Tremblay, Mark S. .
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME, 2013, 38 (05) :520-524