An experimental investigation on the influence of condenser bypass area for the transient and steady-state heat-transfer performance of heat pipes

被引:5
|
作者
Kwon, Cheong Hoon [1 ]
Kwon, Hyuk Su [2 ]
Jung, Eui Guk [2 ]
机构
[1] Kangwon Natl Univ, Dept Energy Resources & Chem Engn, Chunchon 25913, Kangwon Do, South Korea
[2] Kangwon Natl Univ, Sch Mech Syst Engn, Chunchon 25913, Kangwon Do, South Korea
关键词
Thermal resistance; Bypass mass flow rate; Temperature overshoot; Heat pipe; Liquid-bypass line; EVAPORATOR; METHANOL;
D O I
10.1016/j.icheatmasstransfer.2023.107057
中图分类号
O414.1 [热力学];
学科分类号
摘要
Fundamentally, an effective method for improving the performance of transient and steady-state heat transfer is reducing the flow resistance at the phase-change interface based on the counter flow of vapor and liquid within a typical heat pipe. The flow resistance at such an interface is proportional to the volume flow rates of liquid and vapor. Therefore, the flow resistance at the interface can be reduced by limiting the mass flow rate of vapor or liquid. In this study, experiments were performed on a liquid bypass to improve the steady-state thermal performance of heat pipes. A separate bypass tube allowed some liquid to be subcooled in the condenser to bypass the evaporator without passing through the heat pipe. Three liquid-bypass ports were designed and fabricated in a condenser to experimentally investigate the influence of the bypass port area on the thermal performance of the heat pipe under steady-state operation. An on/off valve was attached to each bypass tube port in the condenser to control the bypass flow rate. The results showed that the thermal resistance, an evaluation index of the performance of steady-state heat transfer, generally decreased with an increase in the bypass port area of the condenser. The thermal resistance of a heat pipe with a horizontal tilt angle and one at an inclination angle of 50 degrees decreased by up to 25.5% and 51.6%, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] CHANNEL HEAT-TRANSFER IN HE-II - STEADY-STATE ORIENTATION DEPENDENCE
    CHEN, Z
    VANSCIVER, SW
    CRYOGENICS, 1987, 27 (11) : 635 - 640
  • [42] Steady-state simulation of internal heat-transfer characteristics in a double tube reactor
    Bai, Yong
    Si, Hui
    Wang, Xiao
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 144
  • [43] STEADY-STATE HEAT-TRANSFER ANALYSIS OF MOLTEN CORE - REACTOR VESSEL SYSTEM
    HAGAN, RC
    REYNOLDS, A
    NUCLEAR ENGINEERING AND DESIGN, 1977, 44 (01) : 53 - 59
  • [44] FINITE-ELEMENT ANALYSIS OF STEADY-STATE NONLINEAR HEAT-TRANSFER PROBLEMS
    DONEA, J
    GIULIANI, S
    NUCLEAR ENGINEERING AND DESIGN, 1974, 30 (02) : 205 - 213
  • [45] A TEST FOR ACCURACY OF NUMERICAL-SOLUTIONS OF STEADY-STATE HEAT-TRANSFER PROBLEMS
    WHITLEY, RJ
    HROMADKA, TV
    NUMERICAL HEAT TRANSFER, 1987, 11 (04): : 505 - 509
  • [46] CALCULATION OF THE STEADY-STATE HEAT-TRANSFER THROUGH A SLAB-ON-GROUND FLOOR
    ANDERSON, BR
    BUILDING AND ENVIRONMENT, 1991, 26 (04) : 405 - 415
  • [47] VAPOR FORMATION AND HEAT-TRANSFER IN LIQUID-HELIUM COOLING CHANNELS UNDER TRANSIENT AND STEADY-STATE CONDITIONS
    HILAL, MA
    DAWSON, JW
    GONCZY, JD
    TURNER, LR
    WANG, ST
    IEEE TRANSACTIONS ON MAGNETICS, 1979, 15 (01) : 59 - 62
  • [48] Experimental investigation on the heat transfer performance of heat pipes with porous copper foam wicks
    Shouguang, Y.
    Jiangwei, D.
    Dong, S.
    Sheng, L.
    Jian, L.
    MATERIALS RESEARCH INNOVATIONS, 2015, 19 : 617 - 622
  • [49] EXPERIMENTAL INVESTIGATION OF A HEAT-TRANSFER COEFFICIENT
    Chabicovsky, Martin
    Raudensk, Miroslav
    MATERIALI IN TEHNOLOGIJE, 2013, 47 (03): : 395 - 398
  • [50] Experimental investigation on the heat transfer performance of flat heat pipe embedded with internally cooled condenser
    Rakshith, Bairi Levi
    Asirvatham, Lazarus Godson
    Angeline, Appadurai Anitha
    Raj, J. Perinba Selvin
    Bose, Jefferson Raja
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 230