Within-Person and Between-Sensor Variability in Continuous Glucose Monitoring Metrics

被引:6
作者
Selvin, Elizabeth [1 ,2 ,8 ,9 ]
Wang, Dan [1 ,2 ]
Rooney, Mary R. [1 ,2 ]
Fang, Michael [1 ,2 ]
Echouffo-Tcheugui, Justin B. [2 ,3 ]
Zeger, Scott [2 ,4 ]
Sartini, Joseph [2 ,4 ]
Tang, Olive [1 ,2 ,5 ]
Coresh, Josef [1 ,2 ]
Aurora, R. Nisha [6 ]
Punjabi, Naresh M. [7 ]
机构
[1] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
[2] Johns Hopkins Univ, Welch Ctr Prevent Epidemiol & Clin Res, Baltimore, MD USA
[3] Johns Hopkins Sch Med, Dept Med, Div Endocrinol Diabet & Metab, Baltimore, MD USA
[4] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biostat, Baltimore, MD USA
[5] Johns Hopkins Sch Med, Baltimore, MD USA
[6] Rutgers Robert Wood Johnson Med Sch, Dept Med, New Brunswick, NJ USA
[7] Univ Miami, Miller Sch Med, Div Pulm Crit Care & Sleep Med, Miami, FL USA
[8] Welch Ctr Prevent Epidemiol & Clin Res, Dept Epidemiol, 2024 E Monument St,Ste 2-600, Baltimore, MD 21287 USA
[9] Johns Hopkins Bloomberg Sch Publ Hlth, 2024 E Monument St,Ste 2-600, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
type; 2; diabetes; continuous glucose monitoring; within-person variability; method comparison; AGREEMENT;
D O I
10.1093/clinchem/hvac192
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: The within-person and between-sensor variability of metrics from different interstitial continuous glucose monitoring (CGM) sensors in adults with type 2 diabetes not taking insulin is unclear. METHODS: Secondary analysis of data from 172 participants from the Hyperglycemic Profiles in Obstructive Sleep Apnea randomized clinical trial. Participants simultaneously wore Dexcom G4 and Abbott Libre Pro CGM sensors for up to 2 weeks at baseline and again at the 3-month follow-up visit. RESULTS: At baseline (up to 2 weeks of CGM), mean glucose for both the Abbott and Dexcom sensors was approximately 150 mg/dL (8.3 mmol/L) and time in range (70-180 mg/dL [3.9-10.0 mmol/L]) was just below 80%. When comparing the same sensor at 2 different time points (two 2-week periods, 3 months apart), the within-person coefficient of variation (CVw) in mean glucose was 17.4% (Abbott) and 14.2% (Dexcom). CVw for percent time in range: 20.1% (Abbott) and 18.6% (Dexcom). At baseline, the Pearson correlation of mean glucose from the 2 sensors worn simultaneously was r = 0.86, root mean squared error (RMSE), 13 mg/dL (0.7 mmol/L); for time in range, r = 0.88, RMSE, 8 percentage points. CONCLUSIONS: Substantial variation was observed within sensors over time and across 2 different sensors worn simultaneously on the same individuals. Clinicians should be aware of this variability when using CGM technology to make clinical decisions.
引用
收藏
页码:180 / 188
页数:9
相关论文
共 20 条
[1]  
Abbott Diabetes Care Inc, 2018, FREEST LIBR 14 DAY F
[2]   Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives [J].
Acciaroli, Giada ;
Vettoretti, Martina ;
Facchinetti, Andrea ;
Sparacino, Giovanni .
BIOSENSORS-BASEL, 2018, 8 (01)
[3]   Landscape of Continuous Glucose Monitoring (CGM) and Integrated CGM: Accuracy Considerations [J].
Bailey, Timothy S. ;
Alva, Shridhara .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 :S5-S11
[4]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
CORNBLEET PJ, 1979, CLIN CHEM, V25, P432
[7]   A Comparative Effectiveness Analysis of Three Continuous Glucose Monitors [J].
Damiano, Edward R. ;
El-Khatib, Firas H. ;
Zheng, Hui ;
Nathan, David M. ;
Russell, Steven J. .
DIABETES CARE, 2013, 36 (02) :251-259
[8]  
Dexcom Inc, 2012, DEXC G4 PLAT CONT GL
[9]   Choice of Continuous Glucose Monitoring Systems May Affect Metrics: Clinically Relevant Differences in Times in Ranges [J].
Freckmann, Guido ;
Pleus, Stefan ;
Schauer, Sebastian ;
Link, Manuela ;
Jendrike, Nina ;
Waldenmaier, Delia ;
Haug, Cornelia ;
Stuhr, Andreas .
EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2022, 130 (05) :343-350
[10]  
Freckmann Guido, 2019, J Diabetes Sci Technol, V13, P575, DOI 10.1177/1932296818812062