Comparison of Diagnostic Performance and Image Quality between Topup-Corrected and Standard Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Cholesteatoma Diagnostics

被引:0
作者
Wiesmueller, Marco [1 ,2 ]
Wuest, Wolfgang [1 ,2 ]
Mennecke, Angelika [3 ]
May, Matthias Stefan [1 ,2 ]
Heiss, Rafael [1 ,2 ]
Fuehres, Tobit [1 ]
Janka, Rolf [1 ,2 ]
Uder, Michael [1 ,2 ]
Doerfler, Arnd [3 ]
Laun, Frederik Bernd [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, D-91054 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Imaging Sci Inst, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Neuroradiol, D-91054 Erlangen, Germany
关键词
diffusion-weighted imaging; DWI; cholesteatoma; turbo spin-echo; TSE; echo-planar imaging; EPI; readout-segmented; topup correction; reduced susceptibility-induced distortions; MRI; EPI; TENSOR; HEAD; DWI;
D O I
10.3390/diagnostics13071242
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88-100%), followed by topupDWI with 92% (95% CI: 81-100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59-93%) for reader 1 and 84% (95% CI: 70-98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66-100%) and rsDWI of 89% (95% CI: 52-100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions' conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.
引用
收藏
页数:15
相关论文
共 39 条
  • [1] Detection of cholesteatoma: High-resolution DWI using RS-EPI and parallel imaging at 3 tesla
    Algin, O.
    Aydin, H.
    Ozmen, E.
    Ocakoglu, G.
    Bercin, S.
    Porter, D. A.
    Kutluhan, A.
    [J]. JOURNAL OF NEURORADIOLOGY, 2017, 44 (06) : 388 - 394
  • [2] How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    Andersson, JLR
    Skare, S
    Ashburner, J
    [J]. NEUROIMAGE, 2003, 20 (02) : 870 - 888
  • [3] Optimal Imaging Parameters for Readout-segmented EPI of the Temporal Bone
    Azuma, Toshiya
    Kodama, Takao
    Yano, Takanori
    Enzaki, Masahiro
    Nakamura, Masato
    Murata, Katsutoshi
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (02) : 145 - 152
  • [4] Early development of structural networks and the impact of prematurity on brain connectivity
    Batalle, Dafnis
    Hughes, Emer J.
    Zhang, Hui
    Tournier, J. -Donald
    Tusor, Nora
    Aljabar, Paul
    Wali, Luqman
    Alexander, Daniel C.
    Hajnal, Joseph V.
    Nosarti, Chiara
    Edwards, A. David
    Counsell, Serena J.
    [J]. NEUROIMAGE, 2017, 149 : 379 - 392
  • [5] Non-EPI versus Multishot EPI DWI in Cholesteatoma Detection: Correlation with Operative Findings
    Benson, J. C.
    Carlson, M. L.
    Lane, J., I
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (03) : 573 - 577
  • [6] Cholesteatoma Pearls: Practical Points and Update
    Castle J.T.
    [J]. Head and Neck Pathology, 2018, 12 (3) : 419 - 429
  • [7] The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma
    De Foer, Bert
    Vercruysse, Jean-Philippe
    Bernaerts, Anja
    Maes, Joachim
    Deckers, Filip
    Michiels, Johan
    Somers, Thomas
    Pouillon, Marc
    Offeciers, Erwin
    Casselman, Jan W.
    [J]. NEURORADIOLOGY, 2007, 49 (10) : 841 - 848
  • [8] Dudau Cristina, 2019, BJR Open, V1, P20180015, DOI 10.1259/bjro.20180015
  • [9] Brain tissues have single-voxel signatures in multi-spectral MRI
    German, Alexander
    Mennecke, Angelika
    Martin, Jan
    Hanspach, Jannis
    Liebert, Andrzej
    Herrler, Juergen
    Kuder, Tristan Anselm
    Schmidt, Manuel
    Nagel, Armin
    Uder, Michael
    Doerfler, Arnd
    Winkler, Juergen
    Zaiss, Moritz
    Laun, Frederik Bernd
    [J]. NEUROIMAGE, 2021, 234
  • [10] The minimal preprocessing pipelines for the Human Connectome Project
    Glasser, Matthew F.
    Sotiropoulos, Stamatios N.
    Wilson, J. Anthony
    Coalson, Timothy S.
    Fischl, Bruce
    Andersson, Jesper L.
    Xu, Junqian
    Jbabdi, Saad
    Webster, Matthew
    Polimeni, Jonathan R.
    Van Essen, David C.
    Jenkinson, Mark
    [J]. NEUROIMAGE, 2013, 80 : 105 - 124