Influence of the Tube Angle on the Measurement Accuracy of Peri-Implant Bone Defects in Rectangular Intraoral X-ray Imaging

被引:0
|
作者
Rugani, Petra [1 ]
Weingartner, Katharina [1 ]
Jakse, Norbert [1 ]
机构
[1] Med Univ Graz, Dept Dent Med & Oral Hlth, Div Oral Surg & Orthodont, Billrothgasse 4, A-8010 Graz, Austria
关键词
peri-implant bone level; intra-oral radiography; implantology; RADIOGRAPHIC MEASUREMENT; PARALLELING TECHNIQUE; CONSENSUS REPORT; WORKSHOP; DISEASES; LEVEL; REPRODUCIBILITY; CLASSIFICATION; IMPACT; ERRORS;
D O I
10.3390/jcm13020391
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intraoral radiography in the right-angle technique is the standard procedure to examine the peri-implant bone level in implant follow-up and implant-related studies. For the implementation of the right-angle or parallel technique, mostly ready-made image receptor holders are used. The aim of this experimental study is to analyze changes in the measurement of standardized peri-implant defects caused by a deviation in the position of the image receptor. Methods: Eleven Xive (R) implants (Dentsply Sirona, Bensheim, Germany) were placed in bovine bone, and peri-implant defects of varying depths were created. The preparations were fixed in a specially made test stand, and intraoral radiographs were taken using the right-angle technique with standard film holders at various horizontal and vertical projection angles. Defect measurement was carried out with the imaging software Sidexis 4 V 4.3 (Dentsply Sirona, Bensheim, Germany). Results: With increasing angular deviation, larger deviations between the measured and the real extent of the defect occurred. Vertical tilting caused significant distortion, while horizontal rotation showed less effect. Conclusion: Intraoral radiography only provides a valid representation of the peri-implant bone level for follow-up or as a tool in implant-related studies if a reproducible projection direction is assured.
引用
收藏
页数:14
相关论文
共 11 条
  • [1] Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects
    Song, Dandan
    Shujaat, Sohaib
    Vasconcelos, Karla de Faria
    Huang, Yan
    Politis, Constantinus
    Lambrichts, Ivo
    Jacobs, Reinhilde
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [2] Intraoral radiography lacks accuracy for the assessment of peri-implant bone level - a controlled clinical study
    Christiaens, Veronique
    Jacobs, Reinhilde
    Dierens, Melissa
    Vervaeke, Stijn
    De Bruyn, Hugo
    Koole, Sebastiaan
    Cosyn, Jan
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (04) : 435 - 441
  • [3] Quantitative measurement of peri-implant bone defects using optical coherence tomography
    Kim, Sulhee
    Kang, Se-Ryong
    Park, Hee-Jung
    Kim, Bome
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (02) : 84 - 91
  • [4] Comparative analysis of imaging techniques for diagnostic accuracy of peri-implant bone defects: a meta-analysis
    Lima Bohner, Lauren Oliveira
    Mukai, Eduardo
    Oderich, Elisa
    Porporatti, Andre Luis
    Pacheco-Pereira, Camila
    Tortamano, Pedro
    Canto, Graziela De Luca
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 124 (04): : 432 - +
  • [5] Challenges in detecting various peri-implant bone defects on modified intraoral oblique radiographic projections: evaluation of an artificial mandibular model
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    ORAL RADIOLOGY, 2025, 41 (02) : 248 - 259
  • [6] Rotational panoramic versus Intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible
    Zechner, W
    Watzak, G
    Gahleitner, A
    Busenlechner, D
    Tepper, G
    Watzek, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (06) : 873 - 878
  • [7] Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study
    Hilgenfeld, Tim
    Juerchott, Alexander
    Deisenhofer, Ulrich Karl
    Krisam, Johannes
    Rammelsberg, Peter
    Heiland, Sabine
    Bendszus, Martin
    Schwindling, Franz Sebastian
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 922 - 930
  • [8] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180
  • [9] Influence of implant restorative emergence angle and contour on peri-implant marginal bone loss: A systematic review and meta-analysis
    Atieh, Momen A.
    Shah, Maanas
    Ameen, Mohammed
    Tawse-Smith, Andrew
    Alsabeeha, Nabeel H. M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (05) : 840 - 852
  • [10] Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants-an ex vivo feasibility study
    Miotk, Nikolai
    Schwindling, Franz Sebastian
    Zidan, Moussa
    Juerchott, Alexander
    Rammelsberg, Peter
    Hosseini, Zahra
    Nittka, Mathias
    Heiland, Sabine
    Bendszus, Martin
    Hilgenfeld, Tim
    JOURNAL OF DENTISTRY, 2023, 130