Apnoea-triggered increase in fraction of inspired oxygen in preterm infants: a randomised cross-over study

被引:1
|
作者
Marshall, Andrew [1 ,5 ]
Ladlow, Oliver J. [2 ]
Bannink, Charlotte [2 ]
Lim, Kathleen [3 ]
Ali, Sanoj K. M. [4 ]
Gale, Timothy J. [1 ]
Dargaville, Peter A. [3 ,4 ]
机构
[1] Univ Tasmania, Coll Sci & Engn, Sch Engn, Hobart, Tas, Australia
[2] Univ Tasmania, Coll Hlth & Med, Sch Med, Hobart, Tas, Australia
[3] Univ Tasmania, Menzies Inst Med Res, Coll Hlth & Med, Hobart, Tas, Australia
[4] Royal Hobart Hosp, Dept Paediat, Hobart, Tas, Australia
[5] Univ Tasmania Coll Sci & Engn, Sch Engn, Hobart, Tas, Australia
关键词
Neonatology; Respiratory Medicine; Intensive Care Units; Neonatal; Technology; POSITIVE-PRESSURE VENTILATION; BIRTH-WEIGHT INFANTS; AUTOMATED CONTROL; RESPIRATORY SUPPORT; SUPPLEMENTAL OXYGEN; TREATING APNEA; SATURATION; PREMATURITY; BRADYCARDIA; HYPOXEMIA;
D O I
10.1136/archdischild-2023-325849
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives To investigate the impact of a pre-emptive apnoea triggered oxygen response on oxygen saturation (SpO(2)) targeting following central apnoea in preterm infants. Design Interventional crossover study of a 12-hour period of automated oxygen control with an apnoea response (AR) module, nested within a crossover study of a 24-hour period of automated oxygen control compared with aggregated data from two flanking 12-hour periods of manual control. Setting Neonatal intensive care unit Patients Preterm infants receiving non-invasive respiratory support and supplemental oxygen; median (IQR) birth gestation 27 (26-28) weeks, postnatal age 17 (12-23) days. Intervention Automated oxygen titration with an automated control algorithm modified to include an AR module. Alterations to inspired oxygen concentration (FiO(2)) were actuated by a motorised blender. Desired SpO(2) range was 90-94%. Apnoea detection was by capsule pneumography. Main outcome measures Duration, magnitude and area under the curve (AUC) of SpO(2) deviations following apnoea; frequency and duration of apnoeic events. Comparisons between periods of manual, automated and automated control with AR module. Results In 60 studies in 35 infants, inclusion of the AR module significantly reduced AUC for SpO(2) deviations below baseline compared with both automated and manual control (manual: 87.1%+/- 107.6% s, automated: 84.6%+/- 102.8% s, AR module: 79.4%+/- 102.7% s). However, there was a coincident increase in SpO(2) overshoot (AUC (SpO(2)>SpO(2(onset))); manual: 44.3 +/- 99.9% s, automated: 54.7%+/- 103.4% s, AR module: 65.7%+/- 126.2% s). Conclusion Automated control with a pre-emptive apnoea-triggered FiO(2) boost resulted in a modest reduction in post-apnoea hypoxaemia, but was followed by a greater SpO(2) overshoot.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [21] Multicenter Crossover Study of Automated Control of Inspired Oxygen in Ventilated Preterm Infants
    Claure, Nelson
    Bancalari, Eduardo
    D'Ugard, Carmen
    Nelin, Leif
    Stein, Melanie
    Ramanathan, Rangasamy
    Hernandez, Richard
    Donn, Steven M.
    Becker, Michael
    Bachman, Thomas
    PEDIATRICS, 2011, 127 (01) : E76 - E83
  • [22] Automated control of inspired oxygen in ventilated preterm infants: crossover physiological study
    Lal, Mithilesh
    Tin, Win
    Sinha, Sunil
    ACTA PAEDIATRICA, 2015, 104 (11) : 1084 - 1089
  • [23] Is synchronised NIPPV more effective than NIPPV and NCPAP in treating apnoea of prematurity (AOP)? A randomised cross-over trial
    Gizzi, Camilla
    Montecchia, Francesco
    Panetta, Valentina
    Castellano, Chiara
    Mariani, Chiara
    Campelli, Maristella
    Papoff, Paola
    Moretti, Corrado
    Agostino, Rocco
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2015, 100 (01): : F17 - F23
  • [24] Randomised study comparing extent of hypocarbia in preterm infants during conventional and patient triggered ventilation
    Luyt, K
    Wright, D
    Baumer, JH
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2001, 84 (01): : F14 - F17
  • [25] A randomised cross-over study of methods of acquiring ECG heart rate in newborns
    Murphy, Madeleine C.
    De Angelis, Laura
    McCollum, Danielle
    McCarthy, Lisa K.
    O'Donne, Colm P. F.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2017, 102 (04): : F369 - F370
  • [26] Comparison of cricothyroidotomy on manikin vs. simulator: a randomised cross-over study
    John, B.
    Suri, I.
    Hillermann, C.
    Mendonca, C.
    ANAESTHESIA, 2007, 62 (10) : 1029 - 1032
  • [27] Effect of aggregation form on bioavailability of zeaxanthin in humans: a randomised cross-over study
    Hempel, Judith
    Fischer, Anja
    Fischer, Monique
    Hoegel, Josef
    Bosy-Westphal, Anja
    Carle, Reinhold
    Schweiggert, Ralf M.
    BRITISH JOURNAL OF NUTRITION, 2017, 118 (09) : 698 - 706
  • [28] Veinplicity versus heat treatment for vein dilation: A randomised cross-over study
    Barton, Andrew
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (05): : 530 - 536
  • [29] The Effect of Magnesium Supplementation on Endothelial Function: A Randomised Cross-Over Pilot Study
    Byrne, Jennifer
    Murphy, Caitriona
    Keogh, Jennifer B.
    Clifton, Peter M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (15)
  • [30] Do newborn infants exhale through the CPAP system? Secondary analysis of a randomised cross-over trial
    Gunnarsdottir, Kolbrun
    Falk, Markus
    Baldursdottir, Sonja
    Donaldsson, Snorri
    Jonsson, Baldvin
    Drevhammar, Thomas
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2023, 108 (03): : 232 - 236