Design of highly selective, and sensitive screen-printed electrochemical sensor for detection of uric acid with uricase immobilized polycaprolactone/polyethylene imine electrospun nanofiber

被引:13
|
作者
Muhammad, Fakhriy [1 ]
Dik, Gamze [1 ]
Kolak, Seda [1 ]
Gedik, Kubra Karadas [1 ]
Bakar, Busra [1 ]
Ulu, Ahmet [1 ]
Ates, Burhan [1 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, Biochem & Biomat Res Lab, TR-44280 Malatya, Turkey
关键词
Electrospun nanofiber; Uricase; Enzyme immobilization; Quantum dot screen printed electrode; Differential pulse voltammetry; Uric acid; Biosensor; QUANTUM DOTS; BIOSENSOR; STABILITY; BLUE; POLYETHYLENIMINE; MEDIATOR; POLYMER;
D O I
10.1016/j.electacta.2022.141675
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Uric acid (UA) plays a significant role in nerve center, human metabolism, and kidney system. Therefore, it is necessary to establish a simple, rapid, and sensitive detection method for UA. In recent years, researchers have been highly attracted by nanomaterials with satisfactory functions in electrochemical applications. In this study, polycaprolactone (PCL)/polyethylene imine (PEI) nanofiber membranes were prepared and used for the immobilization of uricase (UOx). The prepared membranes were characterized in terms of structure, composi-tion, and morphology. Afterward, the quantum dot screen printed electrode (QD SPCE) was modified with PCL/ PEI nanofiber membranes with and without methylene blue (MB) as an electron mediator. The electrochemical performance of the developed sensors was investigated by cyclic voltammetry (CV), differential pulse voltam-metry (DPV), and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the modified sensors provided a broad linear range (5.0-52.0 mu M) for the electrochemical detection of UA. Limit of detection (LoD) values were determined as 3.96 mu M and 1.85 mu M for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. The four-week stability results showed the change in current for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE to be 92% and 87%, respectively. Additionally, in the mixed interference test remaining current ratios for UA were 95% and 82% for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. Most importantly, the effectiveness of the electrodes was also verified in real sample detection with satisfactory recovery (similar to 98-112%). Overall, the results showed that the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE have the advantages of simplicity, high sensitivity, and good selectivity for UA determination.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Uricase-stimulated etching of silver nanoprisms for highly selective and sensitive colorimetric detection of uric acid in human serum
    Wu, Dong
    Lu, Hai-Feng
    Xie, He
    Wu, Juan
    Wang, Cheng-Ming
    Zhang, Qun-Lin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1433 - 1440
  • [22] Correction to: A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine
    Yong Yao
    Chunsun Zhang
    Biomedical Microdevices, 2022, 24
  • [23] Biomolecule-Free, Selective Detection of o-Diphenol and Its Derivatives with a Screen-Printed Electrochemical Sensor
    Yu-Ju Chen
    Jen-Lin Chang
    Natarajan Thiyagarajan
    Jyh-Myng Zen
    Electrocatalysis, 2018, 9 : 444 - 451
  • [24] An electrochemical sensor based on a Co3O4-ERGO nanocomposite modified screen-printed electrode for detection of uric acid in artificial saliva
    Turkkan, Gizem
    Bas, Salih Zeki
    Atacan, Keziban
    Ozmen, Mustafa
    ANALYTICAL METHODS, 2022, 14 (01) : 67 - 75
  • [25] A novel flow injection amperometric sensor based on carbon black and graphene oxide modified screen-printed carbon electrode for highly sensitive determination of uric acid
    Reanpang, Preeyaporn
    Mool-am-kha, Pijika
    Upan, Jantima
    Jakmunee, Jaroon
    TALANTA, 2021, 232
  • [26] Highly Sensitive Label-Free Electrochemical Aptasensor Based on Screen-Printed Electrode for Detection of Cadmium (II) Ions
    Li, Yu
    Ran, Guojing
    Lu, Gen
    Ni, Xinyu
    Liu, Daling
    Sun, Jianxia
    Xie, Chunfang
    Yao, Dongsheng
    Bai, Weibin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B449 - B455
  • [27] Electrochemical Sensor Nanoarchitectonics for Sensitive Detection of Uric Acid in Human Whole Blood Based on Screen-Printed Carbon Electrode Equipped with Vertically-Ordered Mesoporous Silica-Nanochannel Film
    Ma, Kai
    Yang, Luoxing
    Liu, Jun
    Liu, Jiyang
    NANOMATERIALS, 2022, 12 (07)
  • [28] Development of a new highly sensitive electrochemical sensor to piroxicam anti-inflammatory determination using a disposable screen-printed electrode
    de Oliveira, Gustavo Zanon de Moraes Goes
    Silva, Francisco Walison Lima
    Lopes, Claudio Sabbatini Capella
    Braz, Bernardo Ferreira
    Santelli, Ricardo Erthal
    Cincotto, Fernando Henrique
    IONICS, 2024, 30 (05) : 2793 - 2806
  • [29] A highly sensitive and selective electrochemical determination of Hg(II) based on an electrochemically activated graphite modified screen-printed carbon electrode
    Palanisamy, Selvakumar
    Madhu, Rajesh
    Chen, Shen-Ming
    Ramaraj, Sayee Kannan
    ANALYTICAL METHODS, 2014, 6 (20) : 8368 - 8373
  • [30] A disposable molecularly imprinted sensor based on Graphe@AuNPs modified screen-printed electrode for highly selective and sensitive detection of cyhexatin in pear samples
    Zhang, Chao
    Zhao, Fengnian
    She, Yongxin
    Hong, Sihui
    Cao, Xiaolin
    Zheng, Lufei
    Wang, Shanshan
    Li, Tengfei
    Wang, Mengqiang
    Jin, Maojun
    Jin, Fen
    Shao, Hua
    Wang, Jing
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 13 - 22