Sensitive electrochemical detection of l-tryptophan using a glassy carbon electrode modified with pectin extracted from Arthrocnemum indicum leaves

被引:5
|
作者
Bourigua, Sondes [1 ]
Boussema, Feriel [1 ]
Bouaazi, Dorsaf [1 ]
Mzoughi, Zeineb [1 ]
Barhoumi, Houcine [1 ]
Majdoub, Hatem [1 ]
Maaref, Abderrazak [1 ]
Jaffrezic-Renault, Nicole [2 ]
机构
[1] Univ Monastir, Fac Sci, Lab Interfaces & Adv Mat, Monastir, Tunisia
[2] Univ Lyon, Inst Analyt Sci, F-69100 Lyon, France
关键词
Pectin; Arthrocnemum indicum leaves; Differential pulse voltammetry; modified GCE; L; -Tryptophan; ASCORBIC-ACID; AMINO-ACIDS; URIC-ACID; SENSOR;
D O I
10.1016/j.jelechem.2023.117998
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pectin from Arthrocnemum indicum leaves (PAI) extracted from plants, harvested in the Tunisian Sahel, was used for the first time as a sensitive matrix for the design of an electrochemical sensor of L-tryptophan via differential pulse voltammetry (DPV). A glassy carbon electrode (GCE) was modified by a PAI layer through simple adsorption, leading to a DPV signal of L-tryptophan that was increased by a factor of 15. The PAI-modified electrode exhibited a good analytical performance towards the detection of L-tryptophan with a wide linear range between 9.10-5 mM to 2.10-2 mM, a detection limit of 0.09 mu M, and a sensitivity of 90.15 mu A. mM-1. Compared to other reported electrochemical sensors, PAI/GCE presents a lower detection limit, even without the use of nanomaterials. In addition, the PAI/GCE showed good reproducibility and good selectivity towards the determination of L-tryptophan versus other amino acids, uric acid, and ascorbic acid, making it suitable for the determination of L-tryptophan in biological fluids.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Sensitive Electrochemical Detection of Dopamine With a Nitrogen-doped Graphene Modified Glassy Carbon Electrode
    Wang, Wencheng
    Gong, Shixing
    Sun, Wei
    Li, Guangjiu
    Lu, Yaping
    Yu, Jianhua
    Dong, Lifeng
    CROATICA CHEMICA ACTA, 2016, 89 (03) : 323 - 330
  • [42] Highly sensitive electrochemical detection of iodate based on glassy carbon electrode modified with iridium oxide
    Yanna Lazarova
    Ivan Shterev
    Totka Dodevska
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1955 - 1962
  • [43] Sensitive and selective determination of tryptophan using a glassy carbon electrode modified with nano-CeO2/reduced graphene oxide composite
    Nie, Xue
    Zhang, Rui
    Tang, Zheng
    Wang, Haiyan
    Deng, Peihong
    Tang, Yougen
    MICROCHEMICAL JOURNAL, 2020, 159
  • [44] Copper oxide nanoflowers/poly-L-glutamic acid modified advanced electrochemical sensor for selective detection of L-tryptophan in real samples
    Khaleque, M. A.
    Bacchu, M. S.
    Ali, M. R.
    Hossain, M. S.
    Mamun, M. R. A.
    Hossain, M. I.
    Khan, M. Z. H.
    HELIYON, 2023, 9 (06)
  • [45] Electrochemical validation of L-tyrosine with dopamine using composite surfactant modified carbon nanotube electrode
    Prinith, Nambudumada S.
    Manjunatha, Jamballi G.
    Hareesha, Nagarajappa
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (12) : 3493 - 3503
  • [46] Nonenzymatic electrochemical detection of rutin on Pt nanoparticles/graphene nanocomposite modified glassy carbon electrode
    Li, Shumin
    Yang, Beibei
    Wang, Jin
    Bin, Duan
    Wang, Caiqin
    Zhang, Ke
    Du, Yukou
    ANALYTICAL METHODS, 2016, 8 (27) : 5435 - 5440
  • [47] A Sensitive Electrochemical Ascorbic Acid Sensor Using Glassy Carbon Electrode Modified by Molybdenite with Electrodeposited Methylene Blue
    Zhang, Yan
    Wang, Yue
    Hasebe, Yasushi
    Zhang, Zhiqiang
    Tao, Dongping
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 191 (04) : 1533 - 1544
  • [48] Electrochemistry and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with a Nafion/TiO2-graphene composite film
    Yang Fan
    Jin-Hang Liu
    Hai-Ting Lu
    Qin Zhang
    Microchimica Acta, 2011, 173 : 241 - 247
  • [49] Electrochemical detection of tryptophan in fish and pharmaceutical supplement at glassy carbon electrode modified with Fe doped ZnO nanoparticle
    Teshome, Toleshi
    Kitte, Shimeles Addisu
    Gure, Abera
    Gonfa, Guta
    ELECTROANALYSIS, 2024, 36 (02)
  • [50] A sensitive electrochemical sensor for the determination of carvedilol based on a modified glassy carbon electrode with ordered mesoporous carbon
    Rofouei, Mohammad Kazem
    Khoshsafar, Hamid
    Kalbasi, Roozbeh Javad
    Bagheri, Hasan
    RSC ADVANCES, 2016, 6 (16): : 13160 - 13167