Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging

被引:3
作者
Karim, Karim S. [1 ,2 ]
Ii, Steven Tilley [2 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[2] KA Imaging, Waterloo, ON N2L 5Z4, Canada
关键词
DIGITAL RADIOGRAPHY; CHEST RADIOGRAPHY; SUBTRACTION;
D O I
10.1093/milmed/usad034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dual-energy subtraction (DES) imaging is well known to reduce anatomical noise and enable material classification. The current approaches to DES imaging have trade-offs, such as motion artifacts, low sensitivity because of losses in a mid-filter, and lack of portability. Recently, a portable triple-layer flat-panel detector (FPD) was proposed for use in single-shot DES imaging that can provide improved sensitivity and removal of motion artifacts in a point-of-care setting. The purpose of this study is to evaluate the feasibility of such a detector. Various image quality metrics and clinical images are provided. Materials and Methods: An FDA-cleared single-exposure DES FPD consisting of three stacked sensors was used for all measurements. This detector generates three images per exposure: A digital radiography (DR) image, i.e., as would be produced with a conventional detector, and two DES images, bone and soft tissue. To evaluate DR image quality, detective quantum efficiency (DQE) and modulation transfer function were measured for multiple radiation quality beams. Digital radiography and DES images obtained from this FPD were evaluated in previously reported fixed and portable clinical studies. Digital radiography and DES images from case studies are presented for qualitative assessment. Results: Modulation transfer function and DQE were measured across multiple radiation quality beams for the DR image. The DES images showed good tissue separation and uniformity with no visible motion or alignment artifacts. The DES images, when read in conjunction with the DR image, resulted in increased reader confidence and revealed abnormalities or details that were sometimes overlooked in the DR image. Conclusions: The proposed panel produces high-quality DR images as indicated by the DQE and modulation transfer function. The DES images have been shown to improve sensitivity in clinical applications and increase reader confidence. This detector can enable DES in portable or otherwise difficult applications, opening new doors for improved patient care.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 31 条
  • [11] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    [J]. Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [12] JEONG HOIWOUN, 2012, [Journal of Radiological Science and Technology, 방사선기술과학], V35, P109
  • [13] CONVENTIONAL CHEST RADIOGRAPHY VS DUAL-ENERGY COMPUTED RADIOGRAPHY IN THE DETECTION AND CHARACTERIZATION OF PULMONARY NODULES
    KELCZ, F
    ZINK, FE
    PEPPLER, WW
    KRUGER, DG
    ERGUN, DL
    MISTRETTA, CA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 271 - 278
  • [14] Improved detection of small lung cancers with dual-energy subtraction chest radiography
    Li, Feng
    Engelmann, Roger
    Doi, Kunio
    MacMahon, Heber
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 886 - 891
  • [15] Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference
    Martini, Katharina
    Baessler, Marco
    Baumueller, Stephan
    Frauenfelder, Thomas
    [J]. PLOS ONE, 2017, 12 (03):
  • [16] Maurino SL., 2021, ECR 2021 EPOS, DOI [10.26044/ecr2021/C-15237, DOI 10.26044/ECR2021/C-15237]
  • [17] Maurino SL., 2019, In European Congress of Radiology - ECR 2019
  • [18] Maurino SL., 2022, ECR 2022 EPOS
  • [19] Determination of the detective quantum efficiency (DQE) of CMOS/CsI imaging detectors following the novel IEC 62220-1-1:2015 International Standard
    Michail, C.
    Valais, I.
    Martini, N.
    Koukou, V.
    Kalyvas, N.
    Bakas, A.
    Kandarakis, I.
    Fountos, G.
    [J]. RADIATION MEASUREMENTS, 2016, 94 : 8 - 17
  • [20] Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography
    Oda, S.
    Awai, K.
    Funama, Y.
    Utsunomiya, D.
    Yanaga, Y.
    Kawanaka, K.
    Nakaura, T.
    Hirai, T.
    Murakami, R.
    Nomori, H.
    Yamashita, Y.
    [J]. CLINICAL RADIOLOGY, 2010, 65 (08) : 609 - 615