Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging

被引:3
作者
Karim, Karim S. [1 ,2 ]
Ii, Steven Tilley [2 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[2] KA Imaging, Waterloo, ON N2L 5Z4, Canada
关键词
DIGITAL RADIOGRAPHY; CHEST RADIOGRAPHY; SUBTRACTION;
D O I
10.1093/milmed/usad034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dual-energy subtraction (DES) imaging is well known to reduce anatomical noise and enable material classification. The current approaches to DES imaging have trade-offs, such as motion artifacts, low sensitivity because of losses in a mid-filter, and lack of portability. Recently, a portable triple-layer flat-panel detector (FPD) was proposed for use in single-shot DES imaging that can provide improved sensitivity and removal of motion artifacts in a point-of-care setting. The purpose of this study is to evaluate the feasibility of such a detector. Various image quality metrics and clinical images are provided. Materials and Methods: An FDA-cleared single-exposure DES FPD consisting of three stacked sensors was used for all measurements. This detector generates three images per exposure: A digital radiography (DR) image, i.e., as would be produced with a conventional detector, and two DES images, bone and soft tissue. To evaluate DR image quality, detective quantum efficiency (DQE) and modulation transfer function were measured for multiple radiation quality beams. Digital radiography and DES images obtained from this FPD were evaluated in previously reported fixed and portable clinical studies. Digital radiography and DES images from case studies are presented for qualitative assessment. Results: Modulation transfer function and DQE were measured across multiple radiation quality beams for the DR image. The DES images showed good tissue separation and uniformity with no visible motion or alignment artifacts. The DES images, when read in conjunction with the DR image, resulted in increased reader confidence and revealed abnormalities or details that were sometimes overlooked in the DR image. Conclusions: The proposed panel produces high-quality DR images as indicated by the DQE and modulation transfer function. The DES images have been shown to improve sensitivity in clinical applications and increase reader confidence. This detector can enable DES in portable or otherwise difficult applications, opening new doors for improved patient care.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 31 条
  • [1] [Anonymous], 1994, IEC 61267 Medical diagnostic X-ray equipment: Radiation conditions for use in the determination of characteristics
  • [2] [Anonymous], 2003, IEC 62220-1
  • [3] [Anonymous], 2018, Varex Imaging
  • [4] Dual-Energy, Dual-Exposure PA and Lateral Chest Radiograph: Not Your Father's Chest X-Ray
    Boswell, Gilbert E.
    Wolfgramm, Sione T.
    Fong, Raynard K.
    Hawley, Daniel B.
    [J]. MILITARY MEDICINE, 2023, 188 (1-2) : 12 - 15
  • [5] A METHOD FOR SELECTIVE TISSUE AND BONE VISUALIZATION USING DUAL ENERGY SCANNED PROJECTION RADIOGRAPHY
    BRODY, WR
    BUTT, G
    HALL, A
    MACOVSKI, A
    [J]. MEDICAL PHYSICS, 1981, 8 (03) : 353 - 357
  • [6] The annual economic burden among patients hospitalized for community-acquired pneumonia (CAP): a retrospective US cohort study
    Divino, Victoria
    Schranz, Jennifer
    Early, Maureen
    Shah, Hemal
    Jiang, Miao
    DeKoven, Mitch
    [J]. CURRENT MEDICAL RESEARCH AND OPINION, 2020, 36 (01) : 151 - 160
  • [7] Dual-energy chest radiography with a flat-panel digital detector:: Revealing calcified chest abnormalities
    Fischbach, F
    Freund, T
    Röttgen, R
    Engert, U
    Felix, R
    Ricke, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (06) : 1519 - 1524
  • [8] Dual energy imaging in cardiothoracic pathologies: A primer for radiologists and clinicians
    Gupta, Amit
    Kikano, Elias G.
    Bera, Kaustav
    Baruah, Dhiraj
    Saboo, Sachin S.
    Lennartz, Simon
    Hokamp, Nils Grosse
    Gholamrezanezhad, Ali
    Gilkeson, Robert C.
    Laukamp, Kai R.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [9] Haggstrom M., 2017, High-resolution computed tomograph of a normal thorax, axial plane (60).jpg
  • [10] Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
    Han, Jong Chul
    Kim, Ho Kyung
    Kim, Dong Woon
    Yun, Seungman
    Youn, Hanbean
    Kam, Soohwa
    Tanguay, Jesse
    Cunningham, Ian A.
    [J]. CURRENT APPLIED PHYSICS, 2014, 14 (12) : 1734 - 1742