Concurrent adjacent strabismus surgery with glaucoma drainage device placement in childhood glaucomas

被引:0
|
作者
Jacobson, Adam [1 ]
Bohnsack, Brenda L. [2 ,3 ]
机构
[1] Univ Michigan, Dept Ophthalmol & Visual Sci, 1000 Wall St, Ann Arbor, MI 48105 USA
[2] Ann & Robert H Lurie Childrens Hosp Chicago, Div Ophthalmol, 225 E Chicago Ave, Chicago, IL 60611 USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Ophthalmol, 645 N Michigan Ave, Chicago, IL 60611 USA
关键词
Strabismus; Exotropia; Esotropia; Childhood glaucomas; glaucoma drainage device;
D O I
10.1186/s12886-023-03275-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Determine outcomes of concurrent strabismus surgery with placement of a glaucoma drainage device (GDD) in children.Methods Retrospective review of pediatric patients who underwent simultaneous lateral rectus (LR) muscle surgery with superotemporal GDD placement. Strabismus and GDD success were defined as residual horizontal misalignment < 10 prism diopter (PD) and intraocular pressure (IOP) < 21 mmHg, no visually devastating complications, and no additional IOP-lowering surgeries.Results Fifteen eyes of 13 patients (69% male) underwent LR surgery (14 recessions, 1 resection) for exotropia or esotropia simultaneous with GDD placement (13 Baerveldt, 2 Ahmed) at 8.34 +/- 5.26 years. Preoperative visual acuity (VA) in operative eye (0.89 +/- 0.54) was worse than non-operative eye (0.23 +/- 0.44, p = 0.0032). Preoperative horizontal deviation was 38.3 +/- 9.4 PD and LR recession was 7.4 +/- 1.1 mm. At final follow-up, VA in operative eye (0.87 +/- 0.52) was unchanged from preoperative (p = 0.4062). Final IOP was significantly decreased (12.4 +/- 4.7 mmHg vs. 31.1 +/- 11.4 mmHg, p = 0.0001) as was number of glaucoma medications (2.7 +/- 1.7 vs. 1.1 +/- 1.3, p = 0.0037). Five (38%) and 9 patients (69%) met criteria for strabismus and GDD success, respectively. Two eyes required tube revision and endoscopic cyclophotocoagulation and 2 eyes had additional strabismus surgery.Conclusions Concurrent strabismus and GDD surgery decreased horizontal deviation and obtained IOP control. It is important to consider correction of strabismus at time of GDD placement to maximize visual development and improve cosmesis in children with glaucoma.
引用
收藏
页数:7
相关论文
共 39 条
  • [31] Heterologous, Fresh, Human Donor Sclera as Patch Graft Material in Glaucoma Drainage Device Surgery
    Tsoukanas, Dimitrios
    Xanthopoulou, Paraskevi
    Charonis, Alexandros C.
    Theodossiadis, Panagiotis
    Kopsinis, Gerasimos
    Filippopoulos, Theodoros
    JOURNAL OF GLAUCOMA, 2016, 25 (07) : 558 - 564
  • [32] Assessing patient cosmetic satisfaction after glaucoma drainage device surgery for different patch grafts
    Doaa S. Milibari
    Dalal Fatani
    Abeer Ahmad
    Ohoud Owaidhah
    Saleh A. AlObeidan
    Faisal A. Almobarak
    Rizwan Malik
    BMC Ophthalmology, 21
  • [33] Orbital Cellulitis Following Uncomplicated Glaucoma Drainage Device Surgery: Case Report and Review of Literature
    Zheng, Cindy X.
    Uhr, Joshua H.
    Deaner, Jordan D.
    Anhalt, John
    Lin, Michael M.
    Moster, Stephen J.
    Razeghinejad, Reza
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2020, 15 (03) : 412 - 418
  • [34] Sulcus Tube Internal Needle Guidewire Technique for Glaucoma Drainage Device Placement: Improving Surgical Ease and Precision
    Shao, Christine G.
    Gharabagi, Ariess P.
    King, Joshua
    Webel, Aaron D.
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (02) : 635 - 643
  • [35] Assessing patient cosmetic satisfaction after glaucoma drainage device surgery for different patch grafts
    Milibari, Doaa S.
    Fatani, Dalal
    Ahmad, Abeer
    Owaidhah, Ohoud
    AlObeidan, Saleh A.
    Almobarak, Faisal A.
    Malik, Rizwan
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [36] Sulcus Tube Internal Needle Guidewire Technique for Glaucoma Drainage Device Placement: Improving Surgical Ease and Precision
    Christine G. Shao
    Ariess P. Gharabagi
    Joshua King
    Aaron D. Webel
    Ophthalmology and Therapy, 2024, 13 : 635 - 643
  • [37] Endoscopic cyclophotocoagulation versus second glaucoma drainage device after prior aqueous tube shunt surgery
    Murakami, Yohko
    Akil, Handan
    Chahal, Jasdeep
    Dustin, Laurie
    Tan, James
    Chopra, Vikas
    Francis, Brian
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (03) : 241 - 246
  • [38] Orbital anatomy magnetic resonance imaging in diplopic versus non-diplopic patients after glaucoma drainage device placement
    Shah, Saumya M.
    Kilgore, Khin P.
    Bothun, Erick D.
    Hunt, Christopher H.
    Khanna, Cheryl L.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : 341 - 346
  • [39] The Effect of Suture Wick Technique on Early Intraocular Pressure Control After Nonvalved (Baerveldt 350) Glaucoma Drainage Device Surgery
    Rothman, Adam L.
    An, Selena J.
    Herndon, Leon W., Jr.
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1145 - 1150