Development of Three-Dimensional Breast Scan and Measurement Application Using Laser Imaging Detection and Ranging Sensor on iPhone

被引:4
|
作者
Han, Woo Yeon [1 ]
Lee, Seok Joon [2 ]
Chang, Hsien Pin [3 ]
Heo, Jin [3 ]
Eom, Jin Sup [2 ]
Kim, Eun Key [2 ]
Han, Hyun Ho [2 ,4 ]
机构
[1] Yonsei Univ, Yongin Severance Hosp, Dept Plast & Reconstruct Surg, Coll Med, Seoul, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Plast & Reconstruct Surg, Coll Med, Seoul, South Korea
[3] Innoyard Ltd, Seoul, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Plast Surg, Olymp Ro 43 Gil, Seoul, South Korea
关键词
ACCURACY; RECONSTRUCTION; PHOTOGRAPHY; PRECISION; SYSTEM;
D O I
10.1097/PRS.0000000000010405
中图分类号
R61 [外科手术学];
学科分类号
摘要
Laser imaging detection and ranging (LiDAR) is a modern three-dimensional (3D) technology that uses a time-of-flight method based on the round-trip time of an infrared laser beam to detect the presence and features of objects. The iPhone 12 Pro is the first smart mobile device with built-in LiDAR sensors. The authors' team developed a software application based on iOS devices with built-in LiDAR sensors for 3D breast scanning and automatically analyzing the breast's geometric measurement. Breast geometry, including midclavicle-to-nipple distance, sternal notch-to-nipple distance, nipple-to-inframammary fold (IMF) distance, distance between nipples, and body circumference on nipple and IMF level were measured using the software application and tapeline. The relative technical error of measurement (rTEM) value was used to calculate the error ratios between the measurements acquired by the software application and those of the tapeline. Good rTEM values ranging from 2.99% to 5.19% were found in the midclavicle-to-nipple distance, sternal notch-to-nipple distance, distance between nipples, nipple-level circumference, and IMF-level circumference. However, there was a poor rTEM value greater than 10% in the nipple-to-IMF distance. The proposed software application using current iOS devices with built-in LiDAR sensors can provide an ideal 3D scanning system that has a low cost burden, good accuracy, portability, and ease of use.
引用
收藏
页码:1183E / 1187E
页数:5
相关论文
共 35 条
  • [31] Three-dimensional view of out-of-plane artifacts in photoacoustic imaging using a laser-integrated linear-transducer-array probe
    Nguyen, Ho Nhu Y.
    Steenbergen, Wiendelt
    PHOTOACOUSTICS, 2020, 19
  • [32] Monitoring Neoadjuvant Chemotherapy for Breast Cancer by Using Three-dimensional Subharmonic Aided Pressure Estimation and Imaging with US Contrast Agents: Preliminary Experience
    Nam, Kibo
    Eisenbrey, John R.
    Stanczak, Maria
    Sridharan, Anush
    Berger, Adam C.
    Avery, Tiffany
    Palazzo, Juan P.
    Forsberg, Flemming
    RADIOLOGY, 2017, 285 (01) : 53 - 62
  • [33] Detection of the fetal conotruncal anomalies using real-time three-dimensional echocardiography with live xPlane imaging of the fetal ductal arch view
    Xiong, Yi
    Liu, Tao
    Gan, Han Jing
    Wu, Ying
    Xu, Jin Feng
    Ting, Yuen Ha
    Leung, Tak Yeung
    Lau, Tze Kin
    PRENATAL DIAGNOSIS, 2013, 33 (05) : 462 - 466
  • [34] Orthogonal dual-channel single-camera spectral imaging for online measurement of three-dimensional space-time evolution of temperature field in laser melt pool
    Wang, Nian
    Zhang, Mingdong
    Bian, Yinxu
    Zhu, Rihong
    Shen, Hua
    JOURNAL OF MANUFACTURING PROCESSES, 2023, 85 : 695 - 701
  • [35] Accuracy of T1 measurement in dynamic contrast-enhanced breast MRI using two- and three-dimensional variable flip angle fast low-angle shot
    Brookes, JA
    Redpath, TW
    Gilbert, FJ
    Murray, AD
    Staff, RT
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (02): : 163 - 171