Breast radiation dose equivalent and cancer risk estimation during PET/ CT examinations

被引:1
作者
Jambi, Layal [1 ]
Alkhorayef, Mohammed [1 ]
Almuwanis, Mohammed [1 ]
Sulieman, Abdelmoneim [2 ]
机构
[1] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Al Kharj 11942, Saudi Arabia
关键词
Breast cancer; PET/CT; Radiation risk; Medical imaging; REDUCTION;
D O I
10.1016/j.radphyschem.2023.111316
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mammary glands or breasts are radiosensitive organs that makeup 12% of the body's overall radiation sensi-tivity. According to estimates, Saudi Arabia has a 27.3% overall cancer incidence rate for breast cancer. Recent studies reported that breasts get significant organ equivalent doses during diagnostic procedures with ionizing radiation, even though the breast is not the target organ. The objective of this work is to assess the effective and breast equivalent doses during positron emission tomography (PET)/Computed tomography (CT) imaging ex-aminations. The effective and breast equivalent doses per PET/CT (GE PET/CT 710) examination were quantified using the amount of the injected radiopharmaceutical (MBq) (18F-fluorodeoxyglucose (FDG)), and external doses from CT examinations. The average, standard deviation (SD) and range of examined patients' age (years) and body mass index ((BMI), kg/m2) were 58 +/- 11 (39-76) and 30 +/- 5 (20.7-43.1), respectively. Constant administered activity (AA, 185 MBq) and tube potential (120 kVp) were used for all patients. The average, SD, and range of the patients effective dose (mSv) from PET/CT (18F-FDG) examination was 8.0 +/- 0.93 (7.0-10.0) and 2.075 +/- 0.11 (1.91-2.29) in that order. Breast doses are comparable with previous studies during the PET/ CT and mammographic examination. Proper justification criteria and dose optimization are essential to lowering excessive exposure while preserving image quality, especially for young females because they have a higher risk of radiation-induced cancer.
引用
收藏
页数:5
相关论文
共 32 条
[1]   A systematic review of health promotion interventions to increase breast cancer screening uptake: from the last 12 years [J].
Agide, Feleke Doyore ;
Sadeghi, Roya ;
Garmaroudi, Gholamreza ;
Tigabu, Bereket Molla .
EUROPEAN JOURNAL OF PUBLIC HEALTH, 2018, 28 (06) :1149-1155
[2]   Radiobiological risks in terms of effective dose and organ dose from 18F-FDG whole-body PET/CT procedures [J].
Alameen, Suhaib ;
Tamam, Nissren ;
Awadain, Sami ;
Sulieman, Abdelmoneim ;
Alkhaldi, Latifa ;
Ben Hmed, Amira .
SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2021, 28 (10) :5947-5951
[3]  
Alqahtani Wedad Saeed, 2020, AIMS Public Health, V7, P679, DOI [10.3934/publichealth.2020053, 10.3934/publichealth.2020053]
[4]   IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms [J].
Andersson, Martin ;
Johansson, Lennart ;
Eckerman, Keith ;
Mattsson, Soren .
EJNMMI RESEARCH, 2017, 7
[5]  
[Anonymous], 1996, Ann ICRP, V26, P1
[6]   Radiation dose affected by mammographic composition and breast size: first application of a radiation dose management system for full-field digital mammography in Korean women [J].
Baek, Ji Eun ;
Kang, Bong Joo ;
Kim, Sung Hun ;
Lee, Hyun Sil .
WORLD JOURNAL OF SURGICAL ONCOLOGY, 2017, 15
[7]   Image Wisely: A Campaign to Increase Awareness about Adult Radiation Protection [J].
Brink, James A. ;
Amis, E. Stephen, Jr. .
RADIOLOGY, 2010, 257 (03) :601-602
[8]   Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D) [J].
Chen, Marcus Y. ;
Steigner, Michael L. ;
Leung, Steve W. ;
Kumamaru, Kanako K. ;
Schultz, Kurt ;
Mather, Richard T. ;
Arai, Andrew E. ;
Rybicki, Frank J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) :1167-1175
[9]   Recommendations on the use of 18F-FDG PET in oncology [J].
Fletcher, James W. ;
Djulbegovic, Benjamin ;
Soares, Heloisa P. ;
Siegel, Barry A. ;
Lowe, Val J. ;
Lyman, Gary H. ;
Coleman, R. Edward ;
Wahl, Richard ;
Paschold, John Christopher ;
Avrill, Norbert ;
Einhorn, Lawrence H. ;
Suh, W. Warren ;
Samson'O, David ;
Delbekell, Dominique ;
Gorman, Mark ;
Shields, Anthony F. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) :480-508
[10]   Non-FDG PET/CT in Diagnostic Oncology: a pictorial review [J].
Giammarile, Francesco ;
Castellucci, Paolo ;
Dierckx, Rudi ;
Lobato, Enrique Estrada ;
Farsad, Mohsen ;
Hustinx, Roland ;
Jalilian, Amirreza ;
Pellet, Olivier ;
Rossi, Susana ;
Paez, Diana .
EUROPEAN JOURNAL OF HYBRID IMAGING, 2019, 3 (01)