Performance evaluation of a lab-scale subsurface flow-constructed wetland system for textile industry wastewater treatment

被引:5
作者
Selvakumar, Selvaraj [1 ]
Boomiraj, Kovilpillai [2 ]
Durairaj, Sivakumar [3 ,4 ]
Veluswamy, Kumar [5 ]
机构
[1] Tamil Nadu Agr Univ, Water Technol Ctr, Coimbatore, India
[2] Tamil Nadu Agr Univ, Agro Climate Res Ctr, Coimbatore 641003, India
[3] Saveetha Inst Med & Tech Sci, Saveetha Sch Engn, Dept Agr Engn, Chennai, India
[4] Kalasalingam Acad Res & Educ, Dept Agr Engn, Krishnankoil, India
[5] AED ACRI TNAU, Madurai Campus, Madurai 625104, India
关键词
Textile industry wastewater; Constructed wetland; Biochar; Heavy metals; Subsurface flow; Darcy's law; NITROGEN TRANSFORMATION; STABILIZATION PONDS; MASS-BALANCE; REMOVAL; ADSORPTION; DESORPTION; SUPPORT; IMPACT; MODEL; DYES;
D O I
10.1007/s11356-023-29425-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compares biochar (BCW) systems' pollutant removal effectiveness to conventional subsurface flow (CCW) in constructed wetland systems to treat textile wastewater. The two systems were identical in construction, but the biochar was 0.1 m thick over gravel and sand (maximum flow rate of 0.021 m(3) h(-1)) as the primary medium over CCW (flow rate of 0.02 m(3) h(-1)). The results revealed that the BCW approach was more efficient than the CCW system (pebble over sand and gravels) in removing and lowering heavy metals below thresh hold limits such as Cr, Cd, Cu, Pb, Ni, and Zn. The alkaline nature of textile water achieves neutrality in both CCW and BCW. However, BCW is more efficient due to a larger active surface area and the ability to filter out more metal and organic ions. TDS reduction efficiency in BCW was 53.07%, compared to 40.04% in CCW. Heavy metal removal was 100% in BCW at 3 to 12 h, whereas it takes 6 to 24 h in CCW (82% for Cr to 93% for Cu). The quick removal of Na from textile wastewater by BCW was reversed and achieved equilibrium in 24 h in contrast to the CCW system (> 24 h). The findings obtained at the lab scale level demonstrated that the BCW system was more effective in reducing TDS, neutralizing the alkalinity of textile wastewater, and removing heavy metals. This study strongly supports the potential application of biochar-constructed wetlands for textile wastewater treatment.
引用
收藏
页码:102708 / 102724
页数:17
相关论文
共 68 条
[1]   Constructed wetland modified by biochar/zeolite addition for enhanced wastewater treatment [J].
Abedi, Tayebeh ;
Mojiri, Amin .
ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2019, 16
[2]   Constructed wetland as tertiary treatment for municipal wastewater [J].
Ahmed, S. ;
Popov, V. ;
Trevedi, R. C. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WASTE AND RESOURCE MANAGEMENT, 2008, 161 (02) :77-84
[3]  
[Anonymous], 2005, STANDARD METHODS EXA, V21st
[4]  
Anuradha A, 2003, THESIS TAMIL NADU AG
[5]  
Bafana A, 2011, ENVIRON REV, V19, P350, DOI [10.1139/A11-018, 10.1139/a11-018]
[6]  
Benkhaya B., 2017, APPL J ENV ENG SCI, V3, P311, DOI DOI 10.48422/IMIST.PRSM/AJEES-V3I3.9681
[7]  
BENKHAYA S., 2018, Appl J Environ Eng Sci, V4, P1, DOI [10.48422/IMIST.PRSM/ajees-v4i1.11061, DOI 10.48422/IMIST.PRSM/AJEES-V4I1.11061]
[8]   Impact of loads, season, and plant species on the performance of a tropical constructed wetland polishing effluent from sugar factory stabilization ponds [J].
Bojcevska, Hristina ;
Tonderski, Karin .
ECOLOGICAL ENGINEERING, 2007, 29 (01) :66-76
[9]  
Bounds HJ., 1998, SMALL FLOW J, V4, P4
[10]   Evaluation of different substrates to support the growth of Typha latifolia in constructed wetlands treating tannery wastewater over long-term operation [J].
Calheiros, Cristina S. C. ;
Rangel, Antonio O. S. S. ;
Castro, Paula M. L. .