Global method for nonlinear seismic analysis of embedded base-isolated nuclear island buildings in layered sites

被引:5
作者
Li, Jianbo [1 ,2 ]
Liu, Yu [1 ,2 ]
Li, Zhiyuan [3 ]
Lin, Gao [1 ,2 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Inst Earthquake Engn, Dalian 116024, Peoples R China
[3] China Inst Water Resources & Hydropower Res, State Key Lab Simulat & Regulat Water Cycle River, Beijing 100038, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil-structure interaction; Global method; Base isolation capacity; Layered sites; Nuclear island building; Equivalent linearization method; Embedding effects; Beyond design basis earthquake; SOIL-STRUCTURE INTERACTION; PASSIVE ISOLATION MECHANISM; FINITE-ELEMENT-METHOD; MODEL; DESIGN; FOUNDATION; CALIFORNIA; RISK; 3D;
D O I
10.1016/j.istruc.2023.105042
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Owing to the increasing scarcity of high-quality sites, the seismic analysis of base-isolated nuclear power plants (NPPs) under complex non-lithology sites has gained important engineering significance. In this study, a global method for nonlinear numerical analysis was developed for the seismic evaluation of base-isolated NPPs in complex layered sites. The seismic analysis of layered sites is realised using the equivalent linear method and one-dimensional wave propagation theory, the radiation damping of the infinite domain is modelled with a visco-elastic artificial boundary, and the nonlinear behaviour of the isolators is fully considered using a bilinear hysteretic model. Using this method, the influence of soil-structure interaction (SSI) and soil nonlinearity on the behaviour of base-isolated NPPs under the design basis earthquake and beyond design basis earthquake was analysed and compared, in terms of the floor response spectra (FRS) and inter-story displacement angle. In addition, the influence of embedment is also studied. The results show that in layered sites, the SSI significantly amplifies the response values for base-isolated NPPs, and as the ground motion input increases, the soil nonlinearity more effectively inhibits the response of base-isolated NPPs. In addition, embedding can significantly reduce the response, but it increases the FRS at some frequency domains. The isolation effect of baseisolated NPPs decreases significantly when SSI effects are considered, and the soil nonlinearity and embedment have little impact on the base isolation capacity. The method proposed in this study can be easily applied to study base-isolated NPPs in layered sites.
引用
收藏
页数:17
相关论文
共 50 条
[31]   Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes [J].
Alhan, Cenk ;
Ozgur, Murat .
SMART STRUCTURES AND SYSTEMS, 2015, 15 (06) :1439-1461
[32]   Performance-based seismic assessment of conventional and base-isolated steel buildings including environmental impact and resilience [J].
Dong, You ;
Frangopol, Dan M. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (05) :739-756
[33]   Implementation of a coupled FEM-SBFEM for soil-structure interaction analysis of large-scale 3D base-isolated nuclear structures [J].
Li, Jianbo ;
Liu, Yu ;
Lin, Gao .
COMPUTERS AND GEOTECHNICS, 2023, 162
[34]   Dynamic reliability-based assessment for the seismic performance of semi-actively base-isolated buildings with hydraulic dampers [J].
Wang, Xiaoyue ;
Qu, Zhe .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2025, 224
[35]   Application of the Modified Endurance Time Method for Predicting Seismic Response of Base-Isolated Structures Under Pounding [J].
Majdi, Ali ;
Sadeghi-Movahhed, Ataallah ;
Farsangi, Ehsan Noroozinejad ;
Mashayekhi, Mohammadreza ;
Almujibah, Hamad ;
De Domenico, Dario .
JOURNAL OF EARTHQUAKE AND TSUNAMI, 2025,
[36]   Slab Vibration and Horizontal-Vertical Coupling in the Seismic Response of Low-rise Irregular Base-isolated and Conventional Buildings [J].
Pujols, Jean C. Guzman ;
Ryan, Keri L. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (01) :1-36
[37]   Seismic response of 20-story base-isolated and fixed-base reinforced concrete structural wall buildings at a near-fault site [J].
Calugaru, Vladimir ;
Panagiotou, Marios .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2014, 43 (06) :927-948
[38]   Non-stationary stochastic analysis for 3D non-eccentric base-isolated buildings [J].
Zhang, Y.-H. (zhangyh@dlut.edu.cn), 1600, Tsinghua University (30) :198-203+253
[39]   Seismic response control of multi-story base-isolated buildings using a smart electromagnetic friction damper with smooth hysteretic behavior [J].
Amjadian, Mohsen ;
Agrawal, Anil K. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 130 :409-432
[40]   Seismic fragility of base-isolated single-storey unreinforced masonry buildings equipped with classical and recycled rubber bearings in Himalayan regions [J].
Losanno, Daniele ;
Ravichandran, Nagavinothini ;
Parisi, Fulvio .
JOURNAL OF BUILDING ENGINEERING, 2022, 45