Microwave Gas Sensors Based on Electrodeposited Polypyrrole-Nickel Phthalocyanine Hybrid Films

被引:11
作者
Pavel, Ileana-Alexandra [1 ]
Lasserre, Alexis [2 ]
Simon, Leo [2 ]
Rossignol, Jerome [2 ]
Lakard, Sophie [1 ]
Stuerga, Didier [2 ]
Lakard, Boris [1 ]
机构
[1] Univ Franche Comte, UTINAM, CNRS, UMR 6213, F-25030 Besancon, France
[2] UB, Lab Interdisciplinaire Carnot Bourgogne, CNRS, UMR 6303,Dept Interfaces,GERM, F-21078 Dijon, France
关键词
conducting polymers; phthalocyanine; microwave transduction; gas sensor; ammonia; COPPER PHTHALOCYANINE; TETRASULFONATED PHTHALOCYANINE; AMMONIA LEVELS; ELECTROPOLYMERIZATION; POLYANILINE; MORPHOLOGY;
D O I
10.3390/s23125550
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have shown that the incorporation of sulfonated metallophthalocyanines into sensitive sensor materials can improve electron transfer and thus species detection. Herein, we propose a simple and easy alternative to the use of generally expensive sulfonated phthalocyanines by electropolymerizing polypyrrole together with nickel phthalocyanine in the presence of an anionic surfactant. The addition of the surfactant not only helps the incorporation of the water-insoluble pigment into the polypyrrole film, but the obtained structure has increased hydrophobicity, which is a key property for developing efficient gas sensors with low sensitivity to water. The obtained results show the effectiveness of the materials tested for the detection of ammonia in the range of 100 to 400 ppm. It is shown by comparing the microwave sensor responses that the film without nickel phthalocyanine (hydrophilic) produces greater variations than the film with nickel phthalocyanine (hydrophobic). These results are consistent with the expected results since the hydrophobic film is not very sensitive to residual ambient water and therefore does not interfere with the microwave response. However, although this excess response is usually a handicap, as it is a source of drift, in these experiments the microwave response shows great stability in both cases.
引用
收藏
页数:15
相关论文
共 55 条
[1]   Monitoring ammonia to assess halitosis [J].
Amano, A ;
Yoshida, Y ;
Oho, T ;
Koga, T .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 94 (06) :692-696
[2]  
[Anonymous], PERIODIC TABLE EDS A
[3]   Highly selective and sensitive simple sensor based on electrochemically treated nano polypyrrole-sodium dodecyl sulphate film for the detection of para-nitrophenol [J].
Arulraj, Abraham Daniel ;
Vijayan, Muthunanthevar ;
Vasantha, Vairathevar Sivasamy .
ANALYTICA CHIMICA ACTA, 2015, 899 :66-74
[4]   Microstrip Spiral Resonator for Microwave-Based Gas Sensing [J].
Bailly, Guillaume ;
Harrabi, Amal ;
Rossignol, Jerome ;
Michel, Morgane ;
Stuerga, Didier ;
Pribetich, Pierre .
IEEE Sensors Letters, 2017, 1 (04)
[5]   Impedance Spectroscopy of Hierarchical Porous Nanomaterials Based on por-Si, por-Si Incorporated by Ni and Metal Oxides for Gas Sensors [J].
Bobkov, Anton ;
Luchinin, Victor ;
Moshnikov, Vyacheslav ;
Nalimova, Svetlana ;
Spivak, Yulia .
SENSORS, 2022, 22 (04)
[6]   Breath Ammonia Is a Useful Biomarker Predicting Kidney Function in Chronic Kidney Disease Patients [J].
Chan, Ming-Jen ;
Li, Yi-Jung ;
Wu, Chao-Ching ;
Lee, Yu-Chen ;
Zan, Hsiao-Wen ;
Meng, Hsin-Fei ;
Hsieh, Meng-Hsuan ;
Lai, Chao-Sung ;
Tian, Ya-Chung .
BIOMEDICINES, 2020, 8 (11) :1-13
[7]   Correlation between breath ammonia and blood urea nitrogen levels in chronic kidney disease and dialysis patients [J].
Chen, Chang-Chiang ;
Hsieh, Ju-Chun ;
Chao, Cheng-Han ;
Yang, Wei-Shun ;
Cheng, Hui-Teng ;
Chan, Chieh-Kai ;
Lu, Chia-Jung ;
Meng, Hsin-Fei ;
Zan, Hsiao-Wen .
JOURNAL OF BREATH RESEARCH, 2020, 14 (03)
[8]   Microwave signature for gas sensing: 2005 to present [J].
de Fonseca, B. ;
Rossignol, J. ;
Stuerga, D. ;
Pribetich, P. .
URBAN CLIMATE, 2015, 14 :502-515
[9]   Detection of VOCs by microwave transduction using dealuminated faujasite DAY zeolites as gas sensitive materials [J].
de Fonseca, B. ;
Rossignol, J. ;
Bezverkhyy, I. ;
Bellat, J. P. ;
Stuerga, D. ;
Pribetich, P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 :558-565
[10]   Tunable size and shape of conductive poly(N-methylaniline) based on surfactant template and doping [J].
Direksilp, Chatrawee ;
Sirivat, Anuvat .
POLYMER INTERNATIONAL, 2019, 68 (06) :1042-1053