Video-Based Deep Learning to Detect Dyssynergic Defecation with 3D High-Definition Anorectal Manometry

被引:6
|
作者
Levy, Joshua J. [1 ,2 ,3 ,6 ]
Navas, Christopher M. [1 ]
Chandra, Joan A. [1 ]
Christensen, Brock C. [3 ,4 ,5 ]
Vaickus, Louis J. [6 ]
Curley, Michael [1 ]
Chey, William D. [7 ]
Baker, Jason R. [8 ]
Shah, Eric D. [1 ]
机构
[1] Dartmouth Hitchcock Hlth, Sect Gastroenterol & Hepatol, One Med Ctr Dr, Lebanon, NH 03756 USA
[2] Geisel Sch Med Dartmouth, Quantitat Biomed Sci, Lebanon, NH USA
[3] Geisel Sch Med Dartmouth, Dept Epidemiol, Lebanon, NH USA
[4] Geisel Sch Med Dartmouth, Dept Pharmacol & Toxicol, Lebanon, NH USA
[5] Geisel Sch Med Dartmouth, Dept Community & Family Med, Lebanon, NH USA
[6] Dartmouth Hitchcock Hlth, Emerging Diagnost & Invest Technol, Dept Pathol & Lab Med, Lebanon, NH USA
[7] Michigan Med, Div Gastroenterol & Hepatol, Ann Arbor, MI USA
[8] Atrium Hlth, Atrium Motil Lab, Div Gastroenterol, Charlotte, NC USA
基金
美国国家卫生研究院;
关键词
Artificial intelligence; Machine learning; Gastrointestinal motility; Anorectal disorders; Artificial neural network; ARTIFICIAL-INTELLIGENCE; UNITED-STATES; CONSTIPATION; BURDEN;
D O I
10.1007/s10620-022-07759-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background We developed a deep learning algorithm to evaluate defecatory patterns to identify dyssynergic defecation using 3-dimensional high definition anal manometry (3D-HDAM). Aims We developed a 3D-HDAM deep learning algorithm to evaluate for dyssynergia. Methods Spatial-temporal data were extracted from consecutive 3D-HDAM studies performed between 2018 and 2020 at Dartmouth-Hitchcock Health. The technical procedure and gold standard definition of dyssynergia were based on the London consensus, adapted to the needs of 3D-HDAM technology. Three machine learning models were generated: (1) traditional machine learning informed by conventional anorectal function metrics, (2) deep learning, and (3) a hybrid approach. Diagnostic accuracy was evaluated using bootstrap sampling to calculate area-under-the-curve (AUC). To evaluate overfitting, models were validated by adding 502 simulated defecation maneuvers with diagnostic ambiguity. Results 302 3D-HDAM studies representing 1208 simulated defecation maneuvers were included (average age 55.2 years; 80.5% women). The deep learning model had comparable diagnostic accuracy [AUC 0.91 (95% confidence interval 0.89-0.93)] to traditional [AUC 0.93(0.92-0.95)] and hybrid [AUC 0.96(0.94-0.97)] predictive models in training cohorts. However, the deep learning model handled ambiguous tests more cautiously than other models; the deep learning model was more likely to designate an ambiguous test as inconclusive [odds ratio 4.21(2.78-6.38)] versus traditional/hybrid approaches. Conclusions Deep learning is capable of considering complex spatial-temporal information on 3D-HDAM technology. Future studies are needed to evaluate the clinical context of these preliminary findings.
引用
收藏
页码:2015 / 2022
页数:8
相关论文
共 50 条
  • [1] Video-Based Deep Learning to Detect Dyssynergic Defecation with 3D High-Definition Anorectal Manometry
    Joshua J. Levy
    Christopher M. Navas
    Joan A. Chandra
    Brock C. Christensen
    Louis J. Vaickus
    Michael Curley
    William D. Chey
    Jason R. Baker
    Eric D. Shah
    Digestive Diseases and Sciences, 2023, 68 : 2015 - 2022
  • [2] Study on 3D High-Resolution Anorectal Manometry Interrater Agreement in the Evaluation of Dyssynergic Defecation Disorders
    van Oostendorp, Justin Y.
    van Hagen, Pieter
    van der Mijnsbrugge, Grietje J. H.
    Han-Geurts, Ingrid J. M.
    DIAGNOSTICS, 2023, 13 (16)
  • [3] Anal sphincter function as assessed by 3D high definition anorectal manometry
    Mion, Francois
    Garros, Aurelien
    Subtil, Fabien
    Damon, Henri
    Roman, Sabine
    CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2018, 42 (04) : 378 - 381
  • [4] Video-Based Deep Learning Approach for 3D Human Movement Analysis in Institutional Hallways: A Smart Hallway
    McGuirk, Connor J. C.
    Baddour, Natalie
    Lemaire, Edward D.
    COMPUTATION, 2021, 9 (12)
  • [5] Manometric parameters, when measured with the 3-dimensional high-definition anorectal manometry probe, poorly predict prolonged balloon expulsion time
    Woo, Matthew
    Pandey, Armaan
    Gill, Harman
    Li, Dorothy
    Buresi, Michelle
    Nasser, Yasmin
    Sawhney, Summit
    Andrews, Christopher N.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2022, 34 (01)
  • [6] 3D computer vision based on machine learning with deep neural networks: A review
    Vodrahalli, Kailas
    Bhowmik, Achintya K.
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2017, 25 (11) : 676 - 694
  • [7] Role of 3D high resolution anorectal manometry compared to conventional technique in management of constipation and fecal incontinence in children
    Keshtgar, Alireza S.
    Selim, Iman M.
    JOURNAL OF PEDIATRIC SURGERY, 2023, 58 (02) : 251 - 257
  • [8] Optimal surface defect detector design based on deep learning for 3D geometry
    Suh, Sangmin
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [9] A Study on 3D Deep Learning-Based Automatic Diagnosis of Nasal Fractures
    Seol, Yu Jin
    Kim, Young Jae
    Kim, Yoon Sang
    Cheon, Young Woo
    Kim, Kwang Gi
    SENSORS, 2022, 22 (02)
  • [10] A Video-Based Framework for Automatic 3D Localization of Multiple Basketball Players: A Combinatorial Optimization Approach
    Monezi, Lucas Antonio
    Calderani Junior, Anderson
    Mercadante, Luciano Allegretti
    Duarte, Leonardo Tomazeli
    Misuta, Milton S.