An acoustic emission onset time determination method based on Transformer

被引:2
|
作者
Yang, Zhensheng [1 ]
Li, Haoda [2 ]
Chen, Runtu [1 ]
机构
[1] Shanghai Maritime Univ, Sch Logist Engn, Shanghai, Peoples R China
[2] COSCO Shipping Heavy Ind Dalian Co Ltd, 80 Zhongyuan Rd, Dalian 116113, Peoples R China
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2024年 / 23卷 / 05期
基金
中国国家自然科学基金;
关键词
Onset time; acoustic emission; Transformer; low SNR; PICKING; SIGNALS;
D O I
10.1177/14759217231223078
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Acoustic emission (AE) technology, as the main method of non-destructive testing technology, has been widely used in structural health monitoring (known as SHM) in the fields of machinery and civil engineering. Locating the failure source is an important application of SHM, and accurately identifying the moment when the AE signal first reaches the sensor (which is called onset time) is of vital importance. Deep learning model has been widely used in onset time determination of AE signals in recent years due to its powerful feature extraction ability. However, as one of the most popular models, Transformer has not been further studied in such field and its effectiveness remains to be proven. In this paper, a novel AE onset time determination method based on Transformer is proposed. Firstly, a preprocessing method based on segmentation-concatenation is applied to divide original data into several connected small segments, while the integrating labeling method is applied on small label segments. Secondly, the preprocessed data and labels are substituted into the Transformer model for training. Finally, for the sequence processed by the Transformer model, the first-time index that reaches the maximum value is obtained as the determination result. Based on the Hsu-Nielson source AE data, the feasibility and performance of this method are analyzed and compared with several commonly used methods: Akaike information criterion (AIC), short/long term average combined with AIC (STA/LTA-AIC), floating threshold (FT) and 1D-CNN-AIC method. The results show that the proposed method is significantly better than AIC, STA/LTA-AIC and FT. Moreover, the determination efficiency is greatly improved while the performance of the proposed method is close to that of 1D-CNN-AIC. Meanwhile, the method has robust performance especially in low signal-to-noise ratio scenario. In practical applications with small-scale data, the proposed method is of relatively high reference as well as application value.
引用
收藏
页码:3174 / 3194
页数:21
相关论文
共 50 条
  • [21] Acoustic Emission Source Localization with Generalized Regression Neural Network Based on Time Difference Mapping Method
    Z. H. Liu
    Q. L. Peng
    X. Li
    C. F. He
    B. Wu
    Experimental Mechanics, 2020, 60 : 679 - 694
  • [22] Research on the time difference of arrival location method of an acoustic emission source based on visible graph modelling
    Mu, Weilei
    Zou, Zhenxing
    Sun, Hailiang
    Liu, Guijie
    Wang, Shoujun
    INSIGHT, 2018, 60 (12) : 697 - 701
  • [23] Acoustic Emission Source Localization with Generalized Regression Neural Network Based on Time Difference Mapping Method
    Liu, Z. H.
    Peng, Q. L.
    Li, X.
    He, C. F.
    Wu, B.
    EXPERIMENTAL MECHANICS, 2020, 60 (05) : 679 - 694
  • [24] Acoustic emission localization in beams based on time reversed dispersion
    Ernst, R.
    Dual, J.
    ULTRASONICS, 2014, 54 (06) : 1522 - 1533
  • [25] A new acoustic emission damage localization method using synchrosqueezed wavelet transforms picker and time-order method
    Wang, Jingkai
    Huo, Linsheng
    Liu, Chunguang
    Song, Gangbing
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2021, 20 (06): : 2917 - 2935
  • [26] A Method Based on Acoustic Emission for Locating Debris Cloud Impact
    Liu Zhidong
    Pang Baojun
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [27] Time-Transformer for acoustic leak detection in water distribution network
    Liu, Rongsheng
    Zayed, Tarek
    Xiao, Rui
    Hu, Qunfang
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2025, 15 (03) : 759 - 775
  • [28] Possibility of using acoustic emission method for testing load tap changers during normal operation of the transformer
    Cichon, A.
    Berger, P.
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [29] Method of Transformer Transient Acoustic Field Reconstruction Based on Equivalent Source Method and Acoustic Monitoring Point Position Quantitative Evaluation
    Liu Y.
    Wang B.
    Zhou X.
    Yan C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (07): : 2765 - 2775
  • [30] Acoustic Emission Characterization of the Onset of Corrosion in Reinforced Concrete
    Di Benedetti, M.
    De Cais, E.
    Karim, Z.
    Loreto, G.
    Presuel, F.
    Nanni, A.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2012, PTS 1 AND 2, 2012, 8345