Control Design of Grid Synchronization Systems for Grid-Tied Power Converters Using Symmetrical Optimum Method: A Comprehensive Reference

被引:5
|
作者
Golestan, Saeed [1 ]
Guerrero, Josep M. [1 ]
Vasquez, Juan C. [1 ]
Abusorrah, Abdullah M. [2 ]
Khadkikar, Vinod [3 ,4 ]
Rodriguez, Jose [5 ]
机构
[1] Aalborg Univ, AAU Energy, Villum Ctr Res Microgrids CROM, DK-9220 Aalborg, Denmark
[2] King Abdulaziz Univ, Ctr Res Excellence Renewable Energy & Power Syst, Dept Elect & Comp Engn, KA CARE Energy Res & Innovat Ctr,Fac Engn, Jeddah 21589, Saudi Arabia
[3] Khalifa Univ, Adv Power & Energy APEC, Abu Dhabi 127788, U Arab Emirates
[4] Khalifa Univ, Khalifa Univ Space Technol & Innovat KUSTIC Ctr, Elect Engn & Comp Sci Dept, Abu Dhabi 127788, U Arab Emirates
[5] Univ San Sebastian Santiago, Fac Engn, Concepcion 4030000, Chile
关键词
Control tuning; frequency-locked loops (FLLs); linear modeling; linear time invariant (LTI) model; linear time-periodic (LTP) model; phase-locked loops (PLLs); symmetrical optimum method; synchronization systems; PHASE-LOCKED LOOP; VOLTAGE-SOURCE CONVERTERS; 3-PHASE PLLS; IMPLEMENTATION; ALGORITHMS; IMPACTS; FILTER;
D O I
10.1109/TPEL.2023.3292306
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Control design of advanced grid synchronization systems is complex as they are often adaptive nonlinear feedback systems with one or more filtering networks and feedback loops in their structure. This article intends to contribute to addressing this issue. It is shown that the phase or frequency estimation loop of many advanced grid synchronization systems, including 3 phi and 1 phi phase-locked loops and frequency-locked loops equipped with in-loop filters and prefilters, can be well-approximated by a standard type-2 control system in the low-frequency range and an extension of the symmetrical optimum (SO) approach could be used to efficiently tune their control parameters. To better understand all this, an overview of the SO method and its extended version is provided and several case studies are presented. The limitations of this design approach and possible solutions are also discussed.
引用
收藏
页码:13650 / 13673
页数:24
相关论文
共 50 条
  • [1] Synchronization Stability Analysis of Grid-Tied Power Converters under Severe Grid Voltage Sags
    He, Xiuqiang
    Geng, Hua
    Yang, Geng
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1366 - 1371
  • [2] A METHODOLOGY OF LCL FILTER DESIGN FOR GRID-TIED POWER CONVERTERS
    Nardi, Cleidimar
    Stein, Carlos M. O.
    Carati, Emerson G.
    Costa, Jean P.
    Cardoso, Rafael
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [3] Harmonic Compensation Method of Grid-Tied Converters in a Weak Grid
    Deng Hua
    Li Guanyang
    Cui Chen
    Wang Shanlong
    Zhao Zhongtian
    Wang Hongzhao
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 6928 - 6933
  • [4] Open-Loop Synchronization Systems for Grid-Tied Power Converters: Literature Overview, Design Considerations, Advantages, and Disadvantages
    Golestan, Saeed
    Guerrero, Josep M.
    Al-Turki, Yusuf
    Abusorrah, Abdullah M.
    Vasquez, Juan C.
    IEEE INDUSTRIAL ELECTRONICS MAGAZINE, 2022, 16 (03) : 14 - 22
  • [5] Lagrange Multipliers Based Predictive Power Control for Grid-Tied Power Converters
    Li, Haitao
    Liu, Xiaodong
    Zhang, Zhenbin
    2021 IEEE 12TH ENERGY CONVERSION CONGRESS AND EXPOSITION - ASIA (ECCE ASIA), 2021, : 2256 - 2261
  • [6] Robust Predictive Control of Grid-Tied Converters Based on Direct Power Control
    Roberto Fischer, Jonatan
    Alejandro Gonzalez, Sergio
    Carugati, Ignacio
    Herran, Mario A.
    Judewicz, Marcos G.
    Carrica, Daniel O.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) : 5634 - 5643
  • [7] A Comprehensive Analysis of Grid Synchronization Systems for Power Converters
    Dao, Tan
    Biricik, Samet
    Ngo, Tuan
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 4935 - 4940
  • [8] HIL EVALUATION OF CONTROL UNIT IN GRID-TIED CONVERTERS
    Porobic, Vlado B.
    Adzic, Evgenije M.
    Rapaic, Milan R.
    THERMAL SCIENCE, 2016, 20 : S393 - S406
  • [9] Power Synchronization Control of Grid-Tied Inverter: Phase Error Modeling for Unified System Design
    Liu, Ao
    Hou, Chuanchuan
    Zhu, Miao
    Dai, Ningyi
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (04) : 3650 - 3662
  • [10] Grid Forming Control with Inertial and Virtual Admittance Characteristics for Grid-tied Converters
    Zhao, Yuwei
    Zhang, Weiyi
    Wang, Wenqing
    Pan, Zhigang
    PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 6184 - 6189