Development and Initial Characterisation of a Localised Elastin Degradation Ex Vivo Porcine Aortic Aneurysm Model

被引:2
作者
Laffey, Matthew [1 ,2 ]
Tornifoglio, Brooke [1 ,2 ]
Lally, Caitriona [1 ,2 ,3 ,4 ]
机构
[1] Trinity Coll Dublin, Trinity Ctr Biomed Engn, Trinity Biomed Sci Inst, Dublin D02 R590, Ireland
[2] Trinity Coll Dublin, Sch Engn, Dept Mech Mfg & Biomed Engn, Dublin D02 R590, Ireland
[3] Royal Coll Surgeons Ireland, Adv Mat & Bioengn Res Ctr AMBER, Dublin D02 W05, Ireland
[4] Trinity Coll Dublin, Dublin D02 W05, Ireland
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 17期
关键词
aortic aneurysm; ex vivo; aortic model; elastin; elastase; mechanical testing; stent-graft; BIAXIAL MECHANICAL-BEHAVIOR; BIOMECHANICAL BEHAVIOR; OPEN REPAIR; TISSUE; INTERVENTIONS; COMPLICATIONS; ASSOCIATION; MANAGEMENT; MEDICINE; IMAGE;
D O I
10.3390/app13179894
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Aortic aneurysms (AA) occur in 4.8% of people causing 150,000 deaths annually. While endovascular aneurysm repairs reduce surgical morbidity, device-related failures (leak/displacement) are frequent highlighting the need for test models that better represent the mural geometry and compliance changes in human AAs. We aimed to develop and characterise an ex vivo porcine aortic model of AA. The optimal duration of tissue elastase exposure to emulate AA changes in elastin microstructure and content was determined using porcine aortic rings. Elastase-induced changes were quantified morphologically, and mechanical properties assessed via ring tensile testing. Subsequent experiments tested the potential for localised elastase treatment in a 1 cm segment of porcine aorta using a specially designed 3D printed rig. The effect on pressure-diameter behaviour was investigated via inflation-extension testing. Elastase treatment produced time dependent decreases in elastin, resulting in an increased tensile modulus and circumferential length in the ring samples in the final phase of the J-shaped tissue stress-strain curves. In whole aortic segments, localised elastase-induced luminal degradation was successfully limited to a central region. The degree of elastin degradation achieved was sufficient to cause localised dilation with respect to controls under physiological pressures. Localised elastin degradation in porcine aortic segments is feasible and emulates the changes seen clinically in aortic aneurysms.
引用
收藏
页数:19
相关论文
共 65 条
[1]   A comparison of endovascular versus open repair for ruptured abdominal aortic aneurysm - Meta-analysis of propensity score-matched data [J].
Alsusa, Hatim ;
Shahid, Abbas ;
Antoniou, George A. .
VASCULAR, 2022, 30 (04) :628-638
[2]  
[Anonymous], 2021, Measuring Areas Read the Docs-QuPath 2.3 Documentation
[3]   Biomechanical Evaluation of Ascending Aortic Aneurysms [J].
Avanzini, Andrea ;
Battini, Davide ;
Bagozzi, Lorenzo ;
Bisleri, Gianluigi .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[4]   Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions [J].
Avril, Stephane ;
Gee, Michael W. ;
Hemmler, Andre ;
Rugonyi, Sandra .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (12)
[5]   Endovascular stent grafting versus open surgical repair of descending thoracic aortic aneurysms in low-risk patients: A multicenter comparative trial [J].
Bavaria, Joseph E. ;
Appoo, Jehangir J. ;
Makaroun, Michel S. ;
Verter, Joel ;
Yu, Zi-Fan ;
Mitchell, R. Scott .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (02) :369-U17
[6]   DEVELOPMENT AND CHARACTERISATION OF A HUMAN EX-VIVO MODEL OF ANEURYSM [J].
Bianco, R. ;
Di Gregoli, K. ;
Caputo, M. ;
Zakkar, M. ;
George, S. ;
Johnson, J. .
ATHEROSCLEROSIS, 2018, 275 :E144-E145
[7]   A Protocol for a Novel Human Ex Vivo Model of Aneurysm [J].
Bianco, Rosaria ;
Di Gregoli, Karina ;
Caputo, Massimo ;
George, Sarah J. ;
Johnson, Jason L. .
STAR PROTOCOLS, 2020, 1 (03)
[8]   Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing [J].
Biglino, Giovanni ;
Verschueren, Peter ;
Zegels, Raf ;
Taylor, Andrew M. ;
Schievano, Silvia .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[9]   Epidemiology and management of aortic disease: aortic aneurysms and acute aortic syndromes [J].
Bossone, Eduardo ;
Eagle, Kim A. .
NATURE REVIEWS CARDIOLOGY, 2021, 18 (05) :331-348
[10]   Investigation of a small-diameter decellularised artery as a potential scaffold for vascular tissue engineering; biomechanical evaluation and preliminary cell seeding [J].
Campbell, E. M. ;
Cahill, P. A. ;
Lally, C. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 14 :130-142