Accelerated Damage in Metallized Film Capacitors Under Pulse Surge Combined With Rated DC Voltage

被引:2
作者
Zhang, Chuansheng [1 ,2 ]
Feng, Yu [1 ]
Kong, Fei [1 ]
Xing, Zhaoliang [3 ]
Zhang, Cheng [1 ,2 ]
Shao, Tao [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing Int S&T Cooperat Base Plasma Science&Energ, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] State Grid Smart Grid Res Inst Co Ltd, State Key Lab Adv Power Transmiss Technol, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Capacitors; Capacitance; Electrodes; Resistance; Dielectrics; Plasma temperature; Electric breakdown; Capacitance loss; equivalent series resistance (ESR); metallized film capacitors (MFCs); repetitive pulses; self-healing; TEMPERATURE RISE; RELIABILITY;
D O I
10.1109/TPS.2023.3272695
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Metallized film capacitors (MFCs) have good self-healing performance and are widely used in pulsed power supplies, power systems, and aerospace equipment. The self-healing time of MFCs is often in the order of microseconds. When the pulsewidth of overvoltage is close to the self-healing time, MFCs are at risk of insulation failure. In this article, self-healing energy and time under pulse surge combined with rated dc voltage are investigated by analyzing the effect of the number of applied pulses on the capacitance loss, dielectric loss, and equivalent series resistance (ESR) of MFC. The correlation between the number of applied pulses and the capacitance loss of MFC at different repetition frequencies, pulse components, and temperatures is studied, fitting the 5% turning points of capacitance loss. The experimental results show that the multiple types of self-healing occur in an active period of one pulse under microsecond overvoltage. According to the level of injection energy and several typical waveforms from voltage and current, the self-healing process of MFC can be classified into effective self-healing, disruptive self-healing, and fatal self-healing. When effective self-healing occurs in the MFC, the performances remain stable for a certain time. As the number of tolerated pulses increases, disruptive self-healing and fatal self-healing significantly decrease capacitance value but increase dielectric loss and ESR.
引用
收藏
页码:1494 / 1501
页数:8
相关论文
共 27 条
[21]   The Influence of DC Component on the Creepage Discharge Paths in Oil-Pressboard Insulation Under AC-DC Combined Voltage [J].
Zhou, Peng ;
Wu, Guangning ;
Gao, Bo ;
Yang, Yan ;
Hu, Guangcai ;
Liu, Cheng .
IEEE ACCESS, 2020, 8 :96284-96293
[22]   Experimental and Theoretical Study of Corona Inception Threshold in Rod to Plane Electrodes Under AC/DC Combined Voltage: Phase Corresponding to AC Voltage [J].
Xia, Junyi ;
Ma, Ziyu ;
He, Zichen ;
He, Xuyuan ;
Zhao, Luxing ;
Shen, Boyang ;
He, Kun ;
Bian, Xingming .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (01) :403-412
[23]   Analytical Model for Gate-Induced Drain Leakage Current Degradation in Polycrystalline Silicon Thin-Film Transistors Under DC Drain Voltage Stress [J].
Song, Yiming ;
Zhang, Meng ;
Jiang, Zhendong ;
Wong, Man ;
Kwok, Hoi-Sing .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2025, 72 (02) :705-711
[24]   Influence of Aging on Creepage Discharge Characteristics of Oil-Paper Insulation Under AC-DC Combined Voltage [J].
Jin Fubao ;
Zhou Yuanxiang ;
Liang Bin .
IEEE ACCESS, 2021, 9 :49016-49024
[25]   Influence of PD Between Needle and Plate Electrodes on Oil-Pressboard Aging Under Combined AC-DC Voltage [J].
Xue, Zhitong ;
Liu, Hongshun ;
Guo, Ning ;
Guo, Jiahao ;
Xiao, Xiaolong ;
Shi, Mingming ;
Fang, Xin ;
Cong, Haoxi .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) :1288-1295
[26]   Effect of Electric-Field Components on the Flashover Characteristics of Oil-Paper Insulation Under Combined AC-DC Voltage [J].
Jin, Fubao ;
Zhou, Yuanxiang .
IEEE ACCESS, 2023, 11 :556-563
[27]   Current fluctuations reduction strategy based on optimal three-space-vector pulse-width modulation for service-life improvement of DC-link electrolytic capacitors in three-phase voltage-source inverter system [J].
Li, Peihe ;
Shen, Anwen ;
Tang, Qipeng ;
Luo, Xin ;
Xu, Jinbang .
IET ELECTRIC POWER APPLICATIONS, 2024, 18 (01) :128-140