Study of a constrained finite element elbow prosthesis: the influence of the implant placement

被引:1
|
作者
Nalbone, Lorenzo [1 ]
Monac, Francesco [1 ]
Nalbone, Luca [2 ]
Ingrassia, Tommaso [3 ]
Ricotta, Vito [3 ]
Nigrelli, Vincenzo [3 ]
Ferruzza, Massimo [1 ]
Tarallo, Luigi [4 ]
Porcellini, Giuseppe [4 ]
Camarda, Lawrence [1 ]
机构
[1] Univ Palermo, Dept Orthoped & Traumatol DICHIRONS, Via Vespro, I-90100 Palermo, Italy
[2] Univ Messina, Dept Vet Sci, Messina, Italy
[3] Univ Palermo, Dept Engn, Palermo, Italy
[4] Univ Modena, Dept Orthoped & Traumatol, Modena, Italy
关键词
Totel elbow arthroplasty; Biomechanics; Elbow replacement; Prosthetic posizioning; Elbow finite element; ARTHROPLASTY; REPLACEMENT;
D O I
10.1186/s10195-023-00690-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence: 5
引用
收藏
页数:13
相关论文
共 50 条
  • [41] DESIGN OF PATIENT SPECIFIC HIP PROSTHESIS BASED ON FINITE ELEMENT ANALYSIS: A COMPARATIVE STUDY
    Snekhalatha, U.
    Dhason, Raja
    Rajalakshmi, T.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2023, 35 (04):
  • [42] Total elbow arthroplasty: Influence of implant positioning on functional outcomes
    Lenoir, H.
    Micallef, P.
    Djerbi, I.
    Waitzenegger, T.
    Lazerges, C.
    Chammas, M.
    Coulet, B.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (06) : 721 - 727
  • [43] Finite-element investigations on the influence of material selection and geometrical parameters on dental implant performance
    Ogaili, Ahmed Ali Farhan
    Mahdi, Qasim Saleh
    Al-Ameen, Ehsan Sabah
    Jaber, Alaa Abdulhady
    Njim, Emad Kadum
    CURVED AND LAYERED STRUCTURES, 2024, 11 (01):
  • [44] Effect of Anconeus Muscle Blocking on Elbow Kinematics: Electromyographic, Inertial Sensors and Finite Element Study
    Miguel-Andres, Israel
    Alonso-Rasgado, Teresa
    Walmsley, Alan
    Watts, Adam C.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (03) : 775 - 788
  • [45] Linked semi-constrained total elbow prosthesis in chronic arthritis: Results of 18 cases
    Corradi M.
    Frattini M.
    Panno B.
    Tocco S.
    Pogliacomi F.
    MUSCULOSKELETAL SURGERY, 2010, 94 (Suppl 1) : S11 - S23
  • [46] Finite Element Modeling of Resurfacing Hip Prosthesis: Estimation of Accuracy Through Experimental Validation
    Taddei, Fulvia
    Martelli, Saulo
    Gill, Harinderjit Singh
    Cristofolini, Luca
    Viceconti, Marco
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (02):
  • [47] BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A FINITE ELEMENT STUDY
    Bhattacharya, Shambo
    Roy, Sandipan
    Rana, Masud
    Banerjee, Sreerup
    Karmakar, Santanu Kumar
    Biswas, Jayanta Kumar
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (04)
  • [48] Peri-implant bone tissue strains in cases of dehiscence: a finite element study
    Van Oosterwyck, H
    Duyck, J
    Vander Sloten, J
    Van der Perre, G
    Naert, I
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 327 - 333
  • [49] Physiological Loading of the Coonrad/Morrey, Nexel, and Discovery Elbow Systems: Evaluation by Finite Element Analysis
    King, Elizabeth A.
    Favre, Philippe
    Eldemerdash, Amin
    Bischoff, Jeffrey E.
    Palmer, Mark
    Lawton, Jeffrey N.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (01): : 61.e1 - 61.e9
  • [50] Finite element analysis of intraosseous distal radioulnar joint prosthesis
    Gholamian, Farzaneh
    Ashrafi, Mehran
    Moradi, Ali