Study of a constrained finite element elbow prosthesis: the influence of the implant placement

被引:1
|
作者
Nalbone, Lorenzo [1 ]
Monac, Francesco [1 ]
Nalbone, Luca [2 ]
Ingrassia, Tommaso [3 ]
Ricotta, Vito [3 ]
Nigrelli, Vincenzo [3 ]
Ferruzza, Massimo [1 ]
Tarallo, Luigi [4 ]
Porcellini, Giuseppe [4 ]
Camarda, Lawrence [1 ]
机构
[1] Univ Palermo, Dept Orthoped & Traumatol DICHIRONS, Via Vespro, I-90100 Palermo, Italy
[2] Univ Messina, Dept Vet Sci, Messina, Italy
[3] Univ Palermo, Dept Engn, Palermo, Italy
[4] Univ Modena, Dept Orthoped & Traumatol, Modena, Italy
关键词
Totel elbow arthroplasty; Biomechanics; Elbow replacement; Prosthetic posizioning; Elbow finite element; ARTHROPLASTY; REPLACEMENT;
D O I
10.1186/s10195-023-00690-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence: 5
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis
    Huang, Ling-Shiuan
    Huang, Yen-Chang
    Yuan, Cadmus
    Ding, Shinn-Jyh
    Yan, Min
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (01) : 248 - 263
  • [32] Stress Distribution Analysis on Semi Constrained Elbow Prosthesis during Flexion and Extension Motion
    Heidari, M.
    Kadir, M. Rafiq Bin Dato Abdul
    Fallahiarezoodar, A.
    Alizadeh, M.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 215 - +
  • [33] Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis
    Benevides, Fernanda
    Cimoes, Renata
    Vajgel, Andre
    Wilmersdorf, Ramiro Brito
    Farias Vajgel, Bruna de Carvalho
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (04) : 358 - 374
  • [34] Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw System: A Two-Dimensional Finite Element Analysis
    Gomes, Erica Alves
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Capello de Sousa, Edson Antonio
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (06) : 2000 - 2005
  • [35] The influence of the centre of rotation on implant survival using a modular stem hip prosthesis
    Traina, Francesco
    De Fine, Marcello
    Biondi, Federico
    Tassinari, Enrico
    Galvani, Andrea
    Toni, Aldo
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) : 1513 - 1518
  • [36] Finite Element Study of Implant Subsidence and Medial Tilt in Agility Ankle Replacement
    Cui, Yunwei
    Hu, Pan
    Wei, Ning
    Cheng, Xiaodong
    Chang, Wenli
    Chen, Wei
    MEDICAL SCIENCE MONITOR, 2018, 24 : 1124 - 1131
  • [37] Biomechanics study of dental implant-bone system by finite element method
    Iulia Roatesi
    Simona Roatesi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [38] THE FINITE ELEMENT TECHNIQUE IN THE ANALYSYS OF IMPLANT BIOMECHANICS
    Ioanid, Nicoleta
    Necu, N.
    Burlui, V.
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2010, 2 (04): : 26 - 31
  • [39] Optimization of a knee implant with different biomaterials using finite element analysis
    Bhandarkar, Shubham
    Dhatrak, Pankaj
    MATERIALS TODAY-PROCEEDINGS, 2022, 59 : 459 - 467
  • [40] Biomechanics study of dental implant-bone system by finite element method
    Roatesi, Iulia
    Roatesi, Simona
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (06)