Diagnostic performance of silent magnetic resonance angiography for endovascularly-treated intracranial aneurysm follow-up: a prospective study

被引:5
作者
Tan, Song [1 ]
Lu, Yuzhao [1 ]
Li, Bin [1 ]
Yang, Qi [2 ]
Zhou, Xiaobing [1 ]
Wang, Yang [3 ]
机构
[1] Nanchang Univ, Dept Neurosurg, Affiliated Hosp 1, Nanchang, Jiangxi, Peoples R China
[2] Capital Med Univ, Beijing Chaoyang Hosp, Dept Radiol, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Chaoyang Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Aneurysm; Magnetic Resonance Angiography; Intervention; TIME-OF-FLIGHT; COIL EMBOLIZATION; MR-ANGIOGRAPHY; STENT; SCAN;
D O I
10.1136/neurintsurg-2022-018726
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Multiple studies have reported the clinical usefulness of silent magnetic resonance angiography (MRA) in the follow-up of endovascularly-treated aneurysms. However, most previous studies were retrospective or with small sample sizes. The objective of this study was to prospectively evaluate the diagnostic performance of silent MRA in the follow-up of intracranial aneurysms treated by different interventional approaches. Methods Patients with endovascularly-treated intracranial aneurysms and followed by silent MRA and digital subtraction angiography (DSA) were enrolled. The visualization of treated sites on silent MRA was rated on a 5-point scale. The aneurysm occlusion status was evaluated using the Raymond Scale and a simplified two-grade scale. Results A total of 155 patients with 175 treated aneurysms were enrolled. The average score for the visualization of treated sites was 3.92 +/- 0.94, and 93.7% (164/175) had a score >= 3. In the subgroup analysis, except for the simple coiling group which had an obviously higher score (4.95 +/- 0.21), there was no significant difference among the stent-assisted coiling group (3.51 +/- 0.77), flow diversion group (3.74 +/- 0.80), and flow diversion with coiling group (3.40 +/- 1.17). Regarding aneurysm occlusion status, silent MRA and DSA were discordant for only one aneurysm using the Raymond Scale, and the inter-modality consistency was almost perfect (kappa=0.992, 95% CI 0.977 to 1.000). Conclusions Silent MRA showed an excellent diagnostic performance in the follow-up of endovascularly-treated intracranial aneurysms, and may be an ideal option for repeated examinations.
引用
收藏
页码:608 / 613
页数:6
相关论文
共 50 条
[41]   Magnetic resonance angiography or digital subtraction catheter angiography for follow-up of coiled aneurysms: Do we need both? [J].
Lane, Annah ;
Vivian, Philip ;
Coulthard, Alan .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (02) :163-169
[42]   Magnetic Resonance Angiography: Current Status in the Planning and Follow-Up of Endovascular Treatment in Lower-Limb Arterial Disease [J].
Lakshminarayan, Raghuram ;
Simpson, James O. ;
Ettles, Duncan F. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :397-405
[43]   Long-term Magnetic Resonance Angiography Follow-up for Recanalized Vessels after Mechanical Thrombectomy [J].
Enomoto, Yukiko ;
Yoshimura, Shinichi ;
Egashira, Yusuke ;
Takagi, Toshinori ;
Tsujimoto, Masanori ;
Iwama, Toru .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (10) :2834-2839
[44]   Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series [J].
Pierot, Laurent ;
Portefaix, Christophe ;
Boulin, Anne ;
Gauvrit, Jean-Yves .
EUROPEAN RADIOLOGY, 2012, 22 (10) :2255-2263
[45]   MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis [J].
Thomas C. Kwee ;
Robert M. Kwee .
Neuroradiology, 2007, 49 :703-713
[46]   MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis [J].
Kwee, Thomas C. ;
Kwee, Robert M. .
NEURORADIOLOGY, 2007, 49 (09) :703-713
[47]   A follow-up study of autosomal dominant polycystic kidney disease with intracranial aneurysms using 3.0 T three-dimensional time-of-flight magnetic resonance angiography [J].
Jiang, Tao ;
Wang, Peng ;
Qian, Yi ;
Zheng, Xuan ;
Xiao, Liaoyuan ;
Yu, Shengqiang ;
Liu, Shiyuan .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) :1840-1845
[48]   High-resolution CT angiography for follow-up evaluation of intracranial aneurysms treated with the Woven EndoBridge device: comparison with digital subtraction angiography [J].
Suyama, Kenichiro ;
Nakahara, Ichiro ;
Matsumoto, Shoji ;
Koge, Junpei ;
Tanabe, Jun ;
Hasebe, Akiko ;
Fujiwara, Eiji ;
Tanaka, Shiho ;
Mase, Tatsunori ;
Hirose, Yuichi .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2025,
[49]   Can Color Doppler Ultrasound Be Effectively Used as the Follow-Up Modality in Patients Undergoing Splenic Artery Aneurysm Embolization? A Correlational Study between Doppler Ultrasound, Magnetic Resonance Angiography and Digital Subtraction Angiography [J].
Lamparski, Krzysztof ;
Procyk, Grzegorz ;
Bartnik, Krzysztof ;
Korzeniowski, Krzysztof ;
Maciag, Rafal ;
Matsibora, Vadym ;
Sajdek, Michal ;
Dryjanska, Alicja ;
Wnuk, Emilia ;
Rosiak, Grzegorz ;
Maj, Edyta ;
Januszewicz, Magdalena ;
Gasecka, Aleksandra ;
Ostrowski, Tomasz ;
Kaszczewski, Piotr ;
Galazka, Zbigniew ;
Wojtaszek, Mikolaj .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
[50]   Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling—improved image quality by iterative metal artifact reduction [J].
Georg Bier ;
Malte Niklas Bongers ;
Johann-Martin Hempel ;
Anja Örgel ;
Till-Karsten Hauser ;
Ulrike Ernemann ;
Florian Hennersdorf .
Neuroradiology, 2017, 59 :649-654