Diagnostic performance of silent magnetic resonance angiography for endovascularly-treated intracranial aneurysm follow-up: a prospective study

被引:5
作者
Tan, Song [1 ]
Lu, Yuzhao [1 ]
Li, Bin [1 ]
Yang, Qi [2 ]
Zhou, Xiaobing [1 ]
Wang, Yang [3 ]
机构
[1] Nanchang Univ, Dept Neurosurg, Affiliated Hosp 1, Nanchang, Jiangxi, Peoples R China
[2] Capital Med Univ, Beijing Chaoyang Hosp, Dept Radiol, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Chaoyang Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Aneurysm; Magnetic Resonance Angiography; Intervention; TIME-OF-FLIGHT; COIL EMBOLIZATION; MR-ANGIOGRAPHY; STENT; SCAN;
D O I
10.1136/neurintsurg-2022-018726
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Multiple studies have reported the clinical usefulness of silent magnetic resonance angiography (MRA) in the follow-up of endovascularly-treated aneurysms. However, most previous studies were retrospective or with small sample sizes. The objective of this study was to prospectively evaluate the diagnostic performance of silent MRA in the follow-up of intracranial aneurysms treated by different interventional approaches. Methods Patients with endovascularly-treated intracranial aneurysms and followed by silent MRA and digital subtraction angiography (DSA) were enrolled. The visualization of treated sites on silent MRA was rated on a 5-point scale. The aneurysm occlusion status was evaluated using the Raymond Scale and a simplified two-grade scale. Results A total of 155 patients with 175 treated aneurysms were enrolled. The average score for the visualization of treated sites was 3.92 +/- 0.94, and 93.7% (164/175) had a score >= 3. In the subgroup analysis, except for the simple coiling group which had an obviously higher score (4.95 +/- 0.21), there was no significant difference among the stent-assisted coiling group (3.51 +/- 0.77), flow diversion group (3.74 +/- 0.80), and flow diversion with coiling group (3.40 +/- 1.17). Regarding aneurysm occlusion status, silent MRA and DSA were discordant for only one aneurysm using the Raymond Scale, and the inter-modality consistency was almost perfect (kappa=0.992, 95% CI 0.977 to 1.000). Conclusions Silent MRA showed an excellent diagnostic performance in the follow-up of endovascularly-treated intracranial aneurysms, and may be an ideal option for repeated examinations.
引用
收藏
页码:608 / 613
页数:6
相关论文
共 50 条
[31]   Application of zero echo time MR angiography in follow-up of intracranial aneurysm remnant and in-stent lumen after embolization: a comparison study with digital subtraction angiography [J].
Song, Yan ;
Qi, Peng ;
Huang, Juan ;
Jiao, Sheng ;
Zhang, Jintao ;
Wang, Daming ;
Chen, Min .
ACTA RADIOLOGICA, 2020, 61 (04) :480-486
[32]   Stability of ruptured intracranial aneurysms treated with detachable coils: is delayed follow-up angiography warranted? [J].
Tailor, Jignesh ;
Goetz, Pablo ;
Chandrashekar, Hoskote ;
Stephen, Tina ;
Schiariti, Marco ;
Grieve, Joan ;
Watkins, Lawrence ;
Brew, Stefan ;
Robertson, Fergus ;
Kitchen, Neil .
BRITISH JOURNAL OF NEUROSURGERY, 2010, 24 (04) :405-409
[33]   MR-ANGIOGRAPHY IN THE FOLLOW-UP OF INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS TREATED BY THE ENDOVASCULAR METHOD [J].
TOURNADE, A ;
KRUPA, P ;
TAJAHMADY, T ;
OESTERLE, H ;
SENGEL, C ;
COURTHEOUX, P ;
CERFON, JF ;
STILHART, B ;
COSCIA, S ;
SROUR, R .
JOURNAL OF NEURORADIOLOGY, 1994, 21 (04) :255-261
[34]   Diagnostic Performance of Pointwise Encoding Time Reduction with Radial Acquisition Subtraction-based MR Angiography in the Follow-up of Intracranial Aneurysms after Clipping [J].
Kim, Inyoung ;
Ahn, Sung Jun ;
Park, Mina ;
Joo, Bio ;
Kim, Junhyung ;
Suh, Sang Hyun .
CLINICAL NEURORADIOLOGY, 2024, 34 (03) :597-603
[35]   Is digital substraction angiography still needed for the follow-up of intracranial aneurysms treated by embolisation with detachable coils? [J].
Lubicz, Boris ;
Neugroschl, Carine ;
Collignon, Laurent ;
Francois, Olivier ;
Baleriaux, Danielle .
NEURORADIOLOGY, 2008, 50 (10) :841-848
[36]   Is digital substraction angiography still needed for the follow-up of intracranial aneurysms treated by embolisation with detachable coils? [J].
Boris Lubicz ;
Carine Neugroschl ;
Laurent Collignon ;
Olivier François ;
Danielle Balériaux .
Neuroradiology, 2008, 50 :841-848
[37]   Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study [J].
Urbach, H. ;
Dorenbeck, U. ;
von Falkenhausen, M. ;
Wilhelm, K. ;
Willinek, W. ;
Schaller, C. ;
Flacke, S. .
NEURORADIOLOGY, 2008, 50 (05) :383-389
[38]   Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study [J].
H. Urbach ;
U. Dorenbeck ;
M. von Falkenhausen ;
K. Wilhelm ;
W. Willinek ;
C. Schaller ;
S. Flacke .
Neuroradiology, 2008, 50 :383-389
[39]   Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography [J].
Zbigniew Serafin ;
Piotr Strześniewski ;
Władysław Lasek ;
Wojciech Beuth .
Neuroradiology, 2012, 54 :1253-1260
[40]   Medium-Term Angiographic Follow-up and Packing Density Analysis in a Series of 67 Consecutive Intracranial Aneurysms Treated Endovascularly with a Single Coil [J].
Almandoz, Josser E. Delgado ;
Crandall, Benjamin M. ;
Fease, Jennifer L. ;
Kadkhodayan, Yasha ;
Scholz, Jill M. ;
Anderson, Ruth E. ;
Tubman, David E. .
STROKE, 2013, 44 (02)