Comparison between whole-body magnetic resonance imaging and whole-body metaiodobenzylguanidine scintigraphy in the evaluation of primary tumor and metastases in neuroblastoma

被引:0
|
作者
Rodrigues, Monica Matos Correia [1 ]
Lederman, Henrique Manoel [2 ]
Grossman, Iona [2 ]
Castiglioni, Mario Luiz V. [3 ]
Marchetti, Renata [3 ]
Grass, Daphne Centola [2 ]
Luisi, Flavio Augusto Vercillo [1 ,4 ]
Caran, Eliana Maria Monteiro [1 ]
机构
[1] Univ Fed Sao Paulo, Paulista Sch Med, Support Grp Adolescents & Children Canc, Div Pediat Oncol,Inst Pediat Oncol, Sao Paulo, SP, Brazil
[2] Univ Fed Sao Paulo, Paulista Sch Med, Support Grp Adolescents & Children Canc IOP GRAACC, Div Radiol,Inst Pediat Oncol, Sao Paulo, SP, Brazil
[3] Fed Univ Sao Paulo UNIFESP, Imaging Diagnost Dept DDI, Nucl Med, HU, Sao Paulo, SP, Brazil
[4] Fed Univ Sao Paulo EPM UNIFESP, Paulista Sch Med, Support Grp Adolescents & Children Canc IOP GRAACC, Div Pediat Oncol,Inst Pediat Oncol, BR-04023062 Sao Paulo, SP, Brazil
关键词
MIBG; MRI; neoplasm staging; neuroblastoma; nuclear medicine; whole-body scintigraphy; DIFFUSION-WEIGHTED MRI; I-123-MIBG SCINTIGRAPHY; DIAGNOSTIC-VALUE; F-18-FDG PET; CHILDREN; DIFFERENTIATION; CT;
D O I
10.1002/pbc.30820
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundWhole-body metaiodobenzylguanidine (131I-MIBG) scintigraphy is the gold standard method to detect neuroblastoma; however, it depends on radioactive material and is expensive. In contrast, whole-body magnetic resonance imaging (WB-MRI) is affordable in developing countries and has been shown to be effective in the evaluation of solid tumors. This study aimed to compare the sensitivity and specificity of WB-MRI with MIBG in the detection of primary tumors and neuroblastoma metastases.ProcedureThis retrospective study enrolled patients with neuroblastoma between 2013 and 2020. All patients underwent WB-MRI and MIBG at intervals of up to 15 days. The results were marked in a table that discriminated anatomical regions for each patient. Two experts evaluated, independently and in anonymity, the WB-MRI images, and two others evaluated MIBG. The results were compared in terms of sensitivity and specificity, for each patient, considering MIBG as the gold standard. This study was approved by the UNIFESP Ethics Committee.ResultsThirty patients with neuroblastoma were enrolled in this study. The age ranged from 1 to 15 years, with a mean of 5.7 years. The interval between exams (WB-MRI and MIBG) ranged from 1 to 13 days, with an average of 6.67 days. Compared to MIBG, WB-MRI presented a sensitivity and specificity greater than or equal to 90% for the detection of primary neuroblastoma in bones and lymph nodes. When we consider the patient without individualizing the anatomical regions, WB-MRI presented sensitivity of 90% and specificity of 73.33%.ConclusionIn conclusion, WB-MRI is a sensitive and specific method to detect neuroblastoma in bone and lymph nodes and highly sensible to primary tumor diagnosis, suggesting that this test is a viable alternative in places where MIBG is difficult to access. Studies with a larger number of cases are necessary for definitive conclusions.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Whole-body magnetic resonance imaging in children: technique and clinical applications
    Eutsler, Eric P.
    Khanna, Geetika
    PEDIATRIC RADIOLOGY, 2016, 46 (06) : 858 - 872
  • [32] Whole-body magnetic resonance imaging for the assessment of metastatic breast cancer
    Godinho, Marcos Vieira
    Proenca Lobo Lopes, Flavia Paiva
    Costa, Flavia Martins
    CANCER MANAGEMENT AND RESEARCH, 2018, 10 : 6743 - 6756
  • [33] Whole-Body Magnetic Resonance Imaging for Staging Metastatic Thymic Carcinoma
    Han, Hyo Jin
    Park, Seoung Ju
    Min, Kyung Hoon
    Kim, So Ri
    Lee, Min Hee
    Chung, Chi Ryang
    Choi, Kyoung Hwa
    Rhee, Yang Keun
    Jin, Gong Yong
    Chung, Myung Ja
    Lee, Yong Chul
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 (11) : 1573 - 1574
  • [34] Whole-body diffusion-weighted magnetic resonance imaging in oncology
    Jouvet, Jean-Christophe
    Thomson, Vivien
    Durupt, Francois
    Bakir, Melisa
    Berthezene, Yves
    PRESSE MEDICALE, 2010, 39 (05): : 548 - 552
  • [35] Whole-body magnetic resonance imaging: technique, guidelines and key applications
    Summers, Paul
    Saia, Giulia
    Colombo, Alberto
    Pricolo, Paola
    Zugni, Fabio
    Alessi, Sarah
    Marvaso, Giulia
    Jereczek-Fossa, Barbara Alicja
    Bellomi, Massimo
    Petralia, Giuseppe
    ECANCERMEDICALSCIENCE, 2021, 15
  • [36] AUTOMATIC MOTION ARTIFACT DETECTION FOR WHOLE-BODY MAGNETIC RESONANCE IMAGING
    Kuestner, Thomas
    Jandt, Marvin
    Liebgott, Annika
    Mauch, Lukas
    Martirosian, Petros
    Bamberg, Fabian
    Nikolaou, Konstantin
    Gatidis, Sergios
    Schick, Fritz
    Yang, Bin
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 995 - 999
  • [37] Whole-body magnetic resonance imaging in children: technique and clinical applications
    Eric P. Eutsler
    Geetika Khanna
    Pediatric Radiology, 2016, 46 : 858 - 872
  • [38] Role of whole-body magnetic resonance imaging in diagnosing early spondyloarthritis
    Mager, Ann-Kathrin
    Althoff, Christian E.
    Sieper, Joachim
    Hamm, Bernd
    Hermann, Kay-Geert A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (02) : 182 - 188
  • [39] Is whole-body magnetic resonance imaging a source of anxiety in oncological patients?
    Mazzocco, Ketti
    Busacchio, Derna
    Summers, Paul Eugene
    Marzorati, Chiara
    Pricolo, Paola
    Petralia, Giuseppe
    Pravettoni, Gabriella
    CANCER REPORTS, 2023, 6 (03)
  • [40] Whole-Body Magnetic Resonance Imaging: Current Role in Patients with Lymphoma
    Albano, Domenico
    Micci, Giuseppe
    Patti, Caterina
    Midiri, Federico
    Albano, Silvia
    Lo Re, Giuseppe
    Grassedonio, Emanuele
    La Grutta, Ludovico
    Lagalla, Roberto
    Galia, Massimo
    DIAGNOSTICS, 2021, 11 (06)