Meta-analysis of pulse pressure variation (PPV) and stroke volume variation (SVV) studies: a few rotten apples can spoil the whole barrel

被引:2
作者
Michard, Frederic [1 ]
Chemla, Denis [2 ]
Teboul, Jean-Louis [2 ]
机构
[1] MiCo, Vallamand, Switzerland
[2] Fac Med Paris Saclay, Le Kremlin Bicetre, France
关键词
Anaesthesia; Hemodynamic monitoring; Fluid responsiveness; Pulse pressure variation; Prediction; VENTILATION;
D O I
10.1186/s13054-023-04765-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页数:3
相关论文
共 10 条
  • [1] The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials
    Benes, Jan
    Giglio, Mariateresa
    Brienza, Nicola
    Michard, Frederic
    [J]. CRITICAL CARE, 2014, 18 (05) : 1 - 11
  • [2] Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - an observational study in 29 countries
    Hemmes, Sabrine N. T.
    Neto, Ary Serpa
    Binnekade, Jan M.
    Canet, Jaume
    Hedenstierna, Goran
    Jaber, Samir
    Hiesmayr, Michael
    Hollmann, Markus W.
    Mills, Gary H.
    Melo, Marcos F. Vidal
    Pearse, Rupert
    Putensen, Christian
    Schmid, Werner
    Severgnini, Paolo
    Wrigge, Hermann
    de Abreu, Marcelo Gama
    Pelosi, Paolo
    Schultz, Marcus J.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (08) : 492 - 507
  • [3] Low intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality
    Levin, M. A.
    McCormick, P. J.
    Lin, H. M.
    Hosseinian, L.
    Fischer, G. W.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (01) : 97 - 108
  • [4] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [5] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    [J]. CRITICAL CARE, 2023, 27 (01)
  • [6] Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
    Michard, F
    Chemla, D
    Richard, C
    Wysocki, M
    Pinsky, MR
    Lecarpentier, Y
    Teboul, JL
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : 935 - 939
  • [7] Changes in arterial pressure duping mechanical ventilation
    Michard, F
    [J]. ANESTHESIOLOGY, 2005, 103 (02) : 419 - 428
  • [8] Applicability of pulse pressure variation: how many shades of grey?
    Michard, Frederic
    Chemla, Denis
    Teboul, Jean-Louis
    [J]. CRITICAL CARE, 2015, 19
  • [9] Use of 'tidal volume challenge' to improve the reliability of pulse pressure variation
    Myatra, Sheila Nainan
    Monnet, Xavier
    Teboul, Jean-Louis
    [J]. CRITICAL CARE, 2017, 21
  • [10] Arterial Pulse Pressure Variation with Mechanical Ventilation
    Teboul, Jean-Louis
    Monnet, Xavier
    Chemla, Denis
    Michard, Frederic
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (01) : 22 - 31