Validation of an Ear-Worn Wearable Gait Analysis Device

被引:8
作者
Jung, Chang Keun [1 ]
Kim, Jinkyuk [1 ]
Rhim, Hye Chang [2 ,3 ]
机构
[1] Beflex Inc, Beflex Res Ctr, Seoul 06628, South Korea
[2] Harvard Med Sch, Spaulding Rehabil Hosp, Dept Phys Med & Rehabil, Charlestown, MA 02129 USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Foot & Ankle Res & Innovat Lab FARIL, Boston, MA 02115 USA
关键词
gait analysis; running parameter; walking parameter; wearable sensor; impact force; RUNNING GAIT; RUNNERS; RELIABILITY; INJURY; BIOMECHANICS; VALIDITY; FEEDBACK; FORCE;
D O I
10.3390/s23031244
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Wearable devices capable of measuring gait parameters may provide a means to more economical gait analysis compared to conventional equipment comprising of a motion capture system and a forced treadmill. Beflex Coach (Beflex, Republic of Korea) is one such device but worn on the ear as Bluetooth earphones, unlike other wearables worn on the wrist, feet, or torso. In this study, the validity of the device was examined against a motion capture system and a forced treadmill for walking and running parameters. Five walking parameters (cadence, single support time, double support time, vertical oscillation (VO), and instantaneous vertical loading rate (IVLR)) and six running parameters (cadence, stance time, flight time, peak force, VO, and IVLR) were studied. Twenty young adults participated in walking or running on a forced treadmill at different speeds (walking: 0.8, 1.25, and 1.7 m/s for walking; running: 2, 2.5, and 3 m/s) while the two systems operated simultaneously. As a result, all parameters showed excellent associations (ICC > 0.75) and good agreements in Bland-Altman plots. The results of the study support the potential use of the ear-worn device as an inexpensive gait analysis equipment.
引用
收藏
页数:11
相关论文
共 40 条
[1]   Validity and Reliability of a Commercial Fitness Watch for Measuring Running Dynamics [J].
Adams, Douglas ;
Pozzi, Federico ;
Carroll, Anthony ;
Rombach, Andrew ;
Zeni, Joseph, Jr. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (06) :471-476
[2]   Gait Retraining for Injured and Healthy Runners Using Augmented Feedback: A Systematic Literature Review [J].
Agresta, Cristine ;
Brown, Allison .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2015, 45 (08) :576-584
[3]  
Andersen C., 2017, THESIS AALBORG U AAL
[4]   Validation of an ear-worn sensor for gait monitoring using a force-plate instrumented treadmill [J].
Atallah, Louis ;
Wiik, Anatole ;
Jones, Gareth G. ;
Lo, Benny ;
Cobb, Justin P. ;
Amis, Andrew ;
Yang, Guang-Zhong .
GAIT & POSTURE, 2012, 35 (04) :674-676
[5]   The use of wearable devices for walking and running gait analysis outside of the lab: A systematic review [J].
Benson, Lauren C. ;
Clermont, Christian A. ;
Bosnjak, Eva ;
Ferber, Reed .
GAIT & POSTURE, 2018, 63 :124-138
[6]   Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different [J].
Brodie, Matthew A. D. ;
Coppens, Milou J. M. ;
Lord, Stephen R. ;
Lovell, Nigel H. ;
Gschwind, Yves J. ;
Redmond, Stephen J. ;
Del Rosario, Michael Benjamin ;
Wang, Kejia ;
Sturnieks, Daina L. ;
Persiani, Michela ;
Delbaere, Kim .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) :663-674
[7]   Technology-Based Feedback and Its Efficacy in Improving Gait Parameters in Patients with Abnormal Gait: A Systematic Review [J].
Chamorro-Moriana, Gema ;
Jose Moreno, Antonio ;
Luis Sevillano, Jose .
SENSORS, 2018, 18 (01)
[8]   Gait Retraining for the Reduction of Injury Occurrence in Novice Distance Runners 1-Year Follow-up of a Randomized Controlled Trial [J].
Chan, Zoe Y. S. ;
Zhang, Janet H. ;
Au, Ivan P. H. ;
An, Winko W. ;
Shum, Gary L. K. ;
Ng, Gabriel Y. F. ;
Cheung, Roy T. H. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (02) :388-395
[9]   Proximal and distal contributions to lower extremity injury: A review of the literature [J].
Chuter, Vivienne H. ;
de Jonge, Xanne A. K. Janse .
GAIT & POSTURE, 2012, 36 (01) :7-15
[10]  
Cicchetti D., 1994, Psychol Assess, V6, P284, DOI [DOI 10.1037/1040-3590.6.4.284, 10.1037/1040-3590.6.4.284]