Bio-inspired graphene nanocomposite enabled electrochemical immunosensor for detection and quantification of NS1 protein of dengue virus

被引:12
|
作者
Chaturvedi, Mansi [1 ]
Patel, Monika [1 ,2 ]
Mondal, D. P. [1 ,2 ]
Srivastava, Avanish Kumar [1 ,2 ]
Dwivedi, Neeraj [1 ,2 ]
Dhand, Chetna [1 ,2 ]
机构
[1] CSIR, Adv Mat & Proc Res Inst, Hoshangabad Rd, Bhopal 462026, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
关键词
Immunosensor; Graphene; NS1; Protein; Dengue virus; Polydopamine; ANTIGEN; METAL; NANOPARTICLES; ELECTRODE; SENSORS;
D O I
10.1016/j.electacta.2023.143630
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Dengue is a serious illness that affects a large portion of the global population. Infection with the dengue virus may have been silent or symptomatic, making identification crucial for tracking the virus's propagation and protecting society from its catastrophic consequences. The non-structural dengue protein NS1 has been used as a biomarker in the diagnosis of dengue because it circulates widely in the blood during the acute phase of the infection and is associated with viremia. In this study, we have reported the development of an electrochemical immunosensor using nanobio-inspired platform composed of ternary nanocomposite of reduced graphene oxide (rGO), polydopamine (pDA) and gold nanoparticles (AuNPs) immobilized with Anti-NS1 antibodies for the detection of NS1 protein. The nanocomposite formation and antibody immobilization are confirmed using various microscopic, spectroscopic and electrochemical techniques. The differential pulse voltammetry (DPV) has been used to investigate the detailed electrochemical properties and immunosensing response of the developed immunosensor device. The designed immunosensor showed linear detection response for NS1 protein from 1 ng ml- 1 to 100 mu g ml- 1 with a sensitivity of 1.78 ng ml- 1 mA-1 and good shelf life. This developed immunosensor with exceptionally low detection limit revealed its potential for early diagnosis of dengue virus infection.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Electrochemical lateral flow immunosensor for detection and quantification of dengue NS1 protein
    Sinawang, Prima Dewi
    Rai, Varun
    Ionescu, Rodica E.
    Marks, Robert S.
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 400 - 408
  • [2] NS1 glycoprotein detection in serum and urine as an electrochemical screening immunosensor for dengue and Zika virus
    Mendonca, Priscila D.
    Santos, Lorenna K. B.
    Foguel, Marcos, V
    Rodrigues, Marco A. B.
    Cordeiro, Marli T.
    Goncalves, Luis M.
    Marques, Ernesto T. A.
    Dutra, Rosa F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (19) : 4873 - 4885
  • [3] NS1 glycoprotein detection in serum and urine as an electrochemical screening immunosensor for dengue and Zika virus
    Priscila D. Mendonça
    Lorenna K. B. Santos
    Marcos V. Foguel
    Marco A. B. Rodrigues
    Marli T. Cordeiro
    Luís M. Gonçalves
    Ernesto T. A. Marques
    Rosa F. Dutra
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4873 - 4885
  • [4] Salivary Detection of Dengue Virus NS1 Protein with a Label-Free Immunosensor for Early Dengue Diagnosis
    Wasik, Daniel
    Mulchandani, Ashok
    Yates, Marylynn V.
    SENSORS, 2018, 18 (08)
  • [5] Electrochemical Immunosensor Based on Antibody-Nanoparticle Hybrid for Specific Detection of the Dengue Virus NS1 Biomarker
    Darwish, Nadiya T.
    Alrawi, Aoday H.
    Sekaran, Shamala D.
    Alias, Yatimah
    Khor, Sook Mei
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (03) : B19 - B25
  • [6] Electrochemical Immunosensor Based on Al-TCPP Nanomaterial Adsorption Aggregation Signal Amplification for the Detection of Dengue Virus NS1 Protein
    Zixuan Zhang
    Wei Li
    Jie Liu
    Ying Li
    Jingfu Qiu
    Chaorui Li
    Electrocatalysis, 2024, 15 : 10 - 19
  • [7] Electrochemical Immunosensor Based on Al-TCPP Nanomaterial Adsorption Aggregation Signal Amplification for the Detection of Dengue Virus NS1 Protein
    Zhang, Zixuan
    Li, Wei
    Liu, Jie
    Li, Ying
    Qiu, Jingfu
    Li, Chaorui
    ELECTROCATALYSIS, 2024, 15 (01) : 10 - 19
  • [8] Development of a portable and disposable NS1 based electrochemical immunosensor for early diagnosis of dengue virus
    Nawaz, Mian Hasnain
    Hayat, Akhtar
    Catanante, Gaelle
    Latif, Usman
    Marty, Jean Louis
    ANALYTICA CHIMICA ACTA, 2018, 1026 : 1 - 7
  • [9] Screen Printed Carbon Electrode Based Electrochemical Immunosensor for the Detection of Dengue NS1 Antigen
    Parkash, Om
    Yean, Chan Yean
    Shueb, Rafidah Hanim
    DIAGNOSTICS, 2014, 4 (04): : 165 - 180
  • [10] Electrochemical detection of dengue virus NS1 protein with a poly(allylamine)/carbon nanotube layered immunoelectrode
    Silva, Mizia M. S.
    Dias, Ana C. M. S.
    Silva, Barbara V. M.
    Gomes-Filho, Sergio L. R.
    Kubota, Lauro T.
    Goulart, Marilia O. F.
    Dutra, Rosa F.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (01) : 194 - 200