Visual simulations of presbyopic corrections through cataract opacification

被引:3
作者
Barcala, Xoana [1 ,2 ]
Zaytouny, Amal [1 ]
Rego-Lorca, Daniela [3 ]
Sanchez-Quiros, Julia [3 ]
Sanchez-Jean, Ruben [3 ]
Maria Martinez-de-la-Casa, Jose [3 ]
Dorronsoro, Carlos [1 ,2 ]
Marcos, Susana [1 ,4 ]
机构
[1] Spanish Natl Res Council, Inst Opt, IO CSIC, Madrid, Spain
[2] 2EyesVision SL, Madrid, Spain
[3] Univ Complutense Madrid, Hosp Clin San Carlos, Serv Oftalmol, Madrid, Spain
[4] Univ Rochester, Inst Opt, Flaum Eye Inst, Ctr Visual Sci, Rochester, NY USA
基金
欧洲研究理事会;
关键词
CRYSTALLINE LENS ABERRATIONS; ADAPTIVE OPTICS; DOUBLE-PASS; IMAGE QUALITY; VISION; EYES;
D O I
10.1097/j.jcrs.0000000000001040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the viability of visual simulation of presbyopic correction in patients with cataract and the effect and impact of the cataract on the perceived visual quality of the different simulated presbyopic corrections preoperatively and postoperatively. Setting: San Carlos Clinical Hospital, Madrid, Spain. Design: Observational, noninterventional, pilot study, early feasibility of the device being studied. Methods: Cataract patients were tested preoperatively ( n = 24) and postoperatively (n = 15) after bilateral implantation of monofocal intraocular lenses (IOLs). The degree of cataract was evaluated objectively with the objective scatter index (OSI). Visual acuity (VA) and perceived visual quality of natural scene images (Multifocal Acceptance Score) were measured before and after cataract surgery at far (4 m), intermediate (64 cm) and near distance (40 cm) with 4 binocular presbyopic corrections (single vision, bifocal, monovision and modified- monovision) simulated with a binocular Simultaneous Vision simulator based on temporal multiplexing. Results: VA was significantly correlated with OSI (r = -0.71, P <.0005), although the visual degradation at far for each correction was constant and not correlated with OSI. The visual benefit at near distance provided by the presbyopic correction was noticeable (23.3% +/- 27.6% across corrections) for OSI <5. The individual perceptual scores were highly correlated preoperatively vs postoperatively (r = 0.64, P <.0005) for all corrections and distances. Conclusions: Visual simulations of IOLs are an excellent tool to explore prospective postoperative vision. The high correlation in the perceptual scores pre- and post-cataract surgery demonstrates that SimVis Gekko can be used in cataractous patients to guide the selection of the optimal correction for a patient.
引用
收藏
页码:34 / 43
页数:10
相关论文
共 35 条
  • [1] Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections
    Akondi, Vyas
    Sawides, Lucie
    Marrakchi, Yassine
    Gambra, Enrique
    Marcos, Susana
    Dorronsoro, Carlos
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6302 - 6317
  • [2] Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations
    Akondi, Vyas
    Dorronsoro, Carlos
    Gambra, Enrique
    Marcos, Susana
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (07): : 3410 - 3425
  • [3] CALCULATIONS OF 2-DIMENSIONAL FOVEAL RETINAL IMAGES IN REAL EYES
    ARTAL, P
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (08): : 1374 - 1381
  • [4] THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    MIRANDA, I
    FERRO, M
    [J]. OPTICAL ENGINEERING, 1995, 34 (03) : 772 - 779
  • [5] Multifocal acceptance score to evaluate vision: MAS-2EV
    Barcala, Xoana
    Vinas, Maria
    Romero, Mercedes
    Gambra, Enrique
    Luis Mendez-Gonzalez, Juan
    Marcos, Susana
    Dorronsoro, Carlos
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Barcala X, 2020, INVEST OPHTH VIS SCI, V61
  • [7] Double-pass measurement of retinal image quality in the chicken eye
    Coletta, NJ
    Marcos, S
    Wildsoet, C
    Troilo, D
    [J]. OPTOMETRY AND VISION SCIENCE, 2003, 80 (01) : 50 - 57
  • [8] Experimental Simulation of Simultaneous Vision
    de Gracia, Pablo
    Dorronsoro, Carlos
    Sanchez-Gonzalez, Alvaro
    Sawides, Lucie
    Marcos, Susana
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 415 - 422
  • [9] Association of optical cataract indices with cataract severity and visual function
    de Souza, Rodrigo Guimaraes
    Golla, Abhinav
    Khan, Mahmood
    de Oca, Ildamaris Montes
    Khandelwal, Sumitra
    Al-Mohtaseb, Zaina
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (01) : 27 - 33
  • [10] Tunable lenses: dynamic characterization and fine-tuned control for high-speed applications
    Dorronsoro, Carlos
    Barcala, Xoana
    Gambra, Enrique
    Akondi, Vyas
    Sawides, Lucie
    Marrakchi, Yassine
    Rodriguez-Lopez, Victor
    Benedi-Garcia, Clara
    Vinas, Maria
    Lage, Eduardo
    Marcos, Susana
    [J]. OPTICS EXPRESS, 2019, 27 (03): : 2085 - 2100