Platinum and palladium nanoparticles on boron-doped diamond for the electrochemical detection of hydrogen peroxide: a comparison study

被引:0
作者
Garcia, Elizabeth M. M. [1 ]
Cordero, Paula A. A. [1 ]
Kazemeini, Sarah [1 ]
Murillo-Soto, Andrea [1 ]
Gonzalez, Karen A. A. [1 ]
McClement, Alexander [1 ]
Rusinek, Cory A. A. [1 ]
机构
[1] Univ Nevada, Dept Chem & Biochem, Las Vegas, NV 89154 USA
基金
美国国家卫生研究院;
关键词
Voltammetry; Boron-doped diamond; Nanoparticles; Hydrogen peroxide; Electrochemical detection; REACTIVE OXYGEN; REAL-TIME; AMPEROMETRIC DETERMINATION; ENHANCED ELECTROCATALYSIS; VOLTAMMETRIC DETECTION; SILVER NANOPARTICLES; SINGLE MACROPHAGE; ELECTRODES; CARBON; OXIDATION;
D O I
10.1007/s00216-023-04859-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrogen peroxide (H2O2) plays a role in many facets - a household item, an important industrial chemical, a biomarker in vivo, and several others. For this reason, its measurement and quantification in a variety of media are important. While spectroscopic detection is primarily used for H2O2, electrochemical methods offer advantages in versatility, cost, and sensitivity. In this work, we investigate a 2-step surface metal nanoparticle (NP) modification for platinum (Pt) and palladium (Pd) on boron-doped diamond (BDD) electrodes for the detection of H2O2. Several parameters such as the metal salt concentration and electrodeposition charge in the 2-step modification were varied to find an optimum. Using cyclic voltammetry (CV), the BDD-PdNP electrode types were found to yield a sharper, more well-resolved H2O2 oxidation peak compared to the BDD-PtNP electrodes. Both metal NP electrode types significantly improved the response compared to the bare BDD electrode; a 150-200x improvement in sensitivity was observed across all modified electrode types. Calibration experiments were completed at both low and high concentration ranges in stagnant and flow-based solutions. The lowest limit of detection (LOD) obtained was 50 nM (5E-08 M) on a BDD-PdNP electrode modified with 1.0 mM PdCl2 to 5.0 mC in the wet chemical seeding and electrodeposition steps. 0.25 mM PdCl2 to 3.23 mC and 0.25 mM HPtCl6- to 3.23 mC also yielded a sufficient response for low-level H2O2, with LODs around 100 nM (1E-07 M). Overall, this work exemplifies the wide applicability of BDD and achieves sub-& mu;M H2O2 LODs with a non-enzymatic electrode material.
引用
收藏
页码:5781 / 5795
页数:15
相关论文
共 77 条
  • [71] Yamanaka I., 2003, ANGEW CHEM, V115, P3781, DOI 10.1002/(ISSN)1521-375710.1002/ange.v115:3110.1002/ange.200351343
  • [72] Size-Controllable Gold-Platinum Alloy Nanoparticles on Nine Functionalized Ionic-Liquid Surfaces and Their Application as Electrocatalysts for Hydrogen Peroxide Reduction
    Yu, Yanyan
    Sun, Qian
    Liu, Xiaoqian
    Wu, Haihong
    Zhou, Tianshu
    Shi, Guoyue
    [J]. CHEMISTRY-A EUROPEAN JOURNAL, 2011, 17 (40) : 11314 - 11323
  • [73] Zhang Q, 2013, BIORESOURCES, V8, P3699
  • [74] ELECTROCHEMICAL OXIDATION OF H2O2 ON PT AND PT + IR ELECTRODES IN PHYSIOLOGICAL BUFFER AND ITS APPLICABILITY TO H2O2-BASED BIOSENSORS
    ZHANG, Y
    WILSON, GS
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2): : 253 - 271
  • [75] A COOH-terminated nitrogen-doped carbon aerogel as a bulk electrode for completely selective two-electron oxygen reduction to H2O2
    Zhao, Hongying
    Shen, Xuqian
    Chen, Ying
    Zhang, Shi-Nan
    Gao, Peng
    Zhen, Xiangjun
    Li, Xin-Hao
    Zhao, Guohua
    [J]. CHEMICAL COMMUNICATIONS, 2019, 55 (44) : 6173 - 6176
  • [76] Novel dendritic palladium nanostructure and its application in biosensing
    Zhou, Ping
    Dai, Zhihui
    Fang, Min
    Huang, Xiaohua
    Bao, Jianchun
    Gong, Jiangfeng
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (34) : 12609 - 12616
  • [77] Electrochemical sensor for formaldehyde based on Pt-Pd nanoparticles and a Nafion-modified glassy carbon electrode
    Zhou, Zhong-Liang
    Kang, Tian-Fang
    Zhang, Yan
    Cheng, Shui-Yuan
    [J]. MICROCHIMICA ACTA, 2009, 164 (1-2) : 133 - 138