Platinum and palladium nanoparticles on boron-doped diamond for the electrochemical detection of hydrogen peroxide: a comparison study

被引:0
作者
Garcia, Elizabeth M. M. [1 ]
Cordero, Paula A. A. [1 ]
Kazemeini, Sarah [1 ]
Murillo-Soto, Andrea [1 ]
Gonzalez, Karen A. A. [1 ]
McClement, Alexander [1 ]
Rusinek, Cory A. A. [1 ]
机构
[1] Univ Nevada, Dept Chem & Biochem, Las Vegas, NV 89154 USA
基金
美国国家卫生研究院;
关键词
Voltammetry; Boron-doped diamond; Nanoparticles; Hydrogen peroxide; Electrochemical detection; REACTIVE OXYGEN; REAL-TIME; AMPEROMETRIC DETERMINATION; ENHANCED ELECTROCATALYSIS; VOLTAMMETRIC DETECTION; SILVER NANOPARTICLES; SINGLE MACROPHAGE; ELECTRODES; CARBON; OXIDATION;
D O I
10.1007/s00216-023-04859-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrogen peroxide (H2O2) plays a role in many facets - a household item, an important industrial chemical, a biomarker in vivo, and several others. For this reason, its measurement and quantification in a variety of media are important. While spectroscopic detection is primarily used for H2O2, electrochemical methods offer advantages in versatility, cost, and sensitivity. In this work, we investigate a 2-step surface metal nanoparticle (NP) modification for platinum (Pt) and palladium (Pd) on boron-doped diamond (BDD) electrodes for the detection of H2O2. Several parameters such as the metal salt concentration and electrodeposition charge in the 2-step modification were varied to find an optimum. Using cyclic voltammetry (CV), the BDD-PdNP electrode types were found to yield a sharper, more well-resolved H2O2 oxidation peak compared to the BDD-PtNP electrodes. Both metal NP electrode types significantly improved the response compared to the bare BDD electrode; a 150-200x improvement in sensitivity was observed across all modified electrode types. Calibration experiments were completed at both low and high concentration ranges in stagnant and flow-based solutions. The lowest limit of detection (LOD) obtained was 50 nM (5E-08 M) on a BDD-PdNP electrode modified with 1.0 mM PdCl2 to 5.0 mC in the wet chemical seeding and electrodeposition steps. 0.25 mM PdCl2 to 3.23 mC and 0.25 mM HPtCl6- to 3.23 mC also yielded a sufficient response for low-level H2O2, with LODs around 100 nM (1E-07 M). Overall, this work exemplifies the wide applicability of BDD and achieves sub-& mu;M H2O2 LODs with a non-enzymatic electrode material.
引用
收藏
页码:5781 / 5795
页数:15
相关论文
共 77 条
  • [51] A Prussian blue-based amperometric sensor for the determination of hydrogen peroxide residues in milk
    Ping, Jianfeng
    Mao, Xiuling
    Fan, Kai
    Li, Dongyang
    Ru, Shiping
    Wu, Jian
    Ying, Yibin
    [J]. IONICS, 2010, 16 (06) : 523 - 527
  • [52] Oxidative Stress: Harms and Benefits for Human Health
    Pizzino, Gabriele
    Irrera, Natasha
    Cucinotta, Mariapaola
    Pallio, Giovanni
    Mannino, Federica
    Arcoraci, Vincenzo
    Squadrito, Francesco
    Altavilla, Domenica
    Bitto, Alessandra
    [J]. OXIDATIVE MEDICINE AND CELLULAR LONGEVITY, 2017, 2017
  • [53] Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
    Purcell, Erin K.
    Becker, Michael F.
    Guo, Yue
    Hara, Seth A.
    Ludwig, Kip A.
    McKinney, Collin J.
    Monroe, Elizabeth M.
    Rechenberg, Robert
    Rusinek, Cory A.
    Saxena, Akash
    Siegenthaler, James R.
    Sortwell, Caryl E.
    Thompson, Cort H.
    Trevathan, James K.
    Witt, Suzanne
    Li, Wen
    [J]. MICROMACHINES, 2021, 12 (02) : 1 - 29
  • [54] Highly sensitive and reusable Pt-black microfluidic electrodes for long-term electrochemical sensing
    Qiang, Liangliang
    Vaddiraju, Santhisagar
    Rusling, James F.
    Papadimitrakopoulos, Fotios
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) : 682 - 688
  • [55] Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests
    Rismetov, Bakhadir
    Ivandini, Tribidasari A.
    Saepudin, Endang
    Einaga, Yasuaki
    [J]. DIAMOND AND RELATED MATERIALS, 2014, 48 : 88 - 95
  • [56] The Hydroxyl Radical is a Critical Intermediate in the Voltammetric Detection of Hydrogen Peroxide
    Roberts, James G.
    Voinov, Maxim A.
    Schmidt, Andreas C.
    Smirnova, Tatyana I.
    Sombers, Leslie A.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2016, 138 (08) : 2516 - 2519
  • [57] Comparison of electrode materials for the detection of rapid hydrogen peroxide fluctuations using background-subtracted fast scan cyclic voltammetry
    Roberts, James G.
    Hamilton, Keri L.
    Sombers, Leslie A.
    [J]. ANALYST, 2011, 136 (17) : 3550 - 3556
  • [58] Sawhorse Waveform Voltammetry for Selective Detection of Adenosine, ATP, and Hydrogen Peroxide
    Ross, Ashley E.
    Venton, B. Jill
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7486 - 7493
  • [59] All-Diamond Microfiber Electrodes for Neurochemical Analysis
    Rusinek, Cory A.
    Rusinek, Cory A.
    Guo, Yue
    Guo, Yue
    Rechenberg, Robert
    Rechenberg, Robert
    Becker, Michael F.
    Becker, Michael F.
    Purcell, Erin
    Purcell, Erin
    Verber, Matthew
    Verber, Matthew
    McKinney, Collin
    Mckinney, Collin
    Li, Wen
    Li, Wen
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (12) : G3087 - G3092
  • [60] Voltammetric Detection of Hydrogen Peroxide at Carbon Fiber Microelectrodes
    Sanford, Audrey L.
    Morton, Stephen W.
    Whitehouse, Kelsey L.
    Oara, Hannah M.
    Lugo-Morales, Leyda Z.
    Roberts, James G.
    Sombers, Leslie A.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5205 - 5210