Clinical Value of Artificial Intelligence-Based Computer-Aided Diagnosis System Versus Contrast-Enhanced Ultrasound for Differentiation of Benign From Malignant Thyroid Nodules in Different Backgrounds

被引:2
作者
Liu, Ting [1 ]
Wu, Chuang [2 ]
Wang, Guojuan [1 ]
Jia, Yingying [1 ]
Zhu, Yangyang [1 ]
Nie, Fang [1 ,3 ]
机构
[1] Lanzhou Univ, Ultrasound Med Ctr, Hosp 2, Lanzhou, Peoples R China
[2] Lanzhou Univ, Dept Magnet Resonance, Hosp 2, Lanzhou, Peoples R China
[3] Lanzhou Univ, Hosp 2, Ultrasound Med Ctr, Dept Ultrasound, Lanzhou 730000, Gansu, Peoples R China
关键词
artificial intelligence; contrast-enhanced ultrasound; thyroid nodules; HASHIMOTO THYROIDITIS; STRATIFICATION; FEATURES;
D O I
10.1002/jum.16195
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The aim of this study was to compare the value of AI-SONIC ultrasound-assisted diagnosis system versus contrast-enhanced ultrasound (CEUS) for differential diagnosis of thyroid nodules in diffuse and non-diffuse backgrounds.Methods-A total of 555 thyroid nodules with pathologically confirmed diagnosis were included in this retrospective study. The diagnostic efficacies of AI-SONIC and CEUS for differentiating benign from malignant nodules in diffuse and non-diffuse backgrounds were evaluated, with pathological diagnosis as the gold standard.Results-The agreement between AI-SONIC diagnosis and pathological diagnosis was moderate in diffuse backgrounds (kappa = 0.417) and almost perfect in non-diffuse backgrounds (kappa = 0.81). The agreement between CEUS diagnosis and pathological diagnosis was substantial in diffuse backgrounds (kappa = 0.684) and moderate in non diffuse backgrounds (kappa = 0.407). In diffuse backgrounds, AI-SONIC had slightly higher sensitivity (95.7 vs 89.4%, P = .375), but CEUS had significantly higher specificity (80.0 vs 40.0%, P = .008). In non-diffuse background, AI-SONIC had significantly higher sensitivity (96.2 vs 73.4%, P < .001), specificity (82.9 vs 71.2%, P = .007), and negative predictive value (90.3 vs 53.3%, P < .001).Conclusion-In non-diffuse backgrounds, AI-SONIC is superior to CEUS for differentiating malignant from benign thyroid nodules. In diffuse backgrounds, AI-SONIC could be useful for screening of cases to detect suspicious nodules requiring further examination by CEUS.
引用
收藏
页码:1757 / 1766
页数:10
相关论文
共 40 条
  • [21] Computer-aided system for diagnosing thyroid nodules on ultrasound: A comparison with radiologist-based clinical assessments
    Gao, Luying
    Liu, Ruyu
    Jiang, Yuxin
    Song, Wenfeng
    Wang, Ying
    Liu, Jia
    Wang, Juanjuan
    Wu, Dongqian
    Li, Shuai
    Hao, Aimin
    Zhang, Bo
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2018, 40 (04): : 778 - 783
  • [22] Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy
    Ursula Nemec
    Stefan F. Nemec
    Clemens Novotny
    Michael Weber
    Christian Czerny
    Christian R. Krestan
    European Radiology, 2012, 22 : 1357 - 1365
  • [23] Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy
    Nemec, Ursula
    Nemec, Stefan F.
    Novotny, Clemens
    Weber, Michael
    Czerny, Christian
    Krestan, Christian R.
    EUROPEAN RADIOLOGY, 2012, 22 (06) : 1357 - 1365
  • [24] Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images
    Gopinath, Balasubramanian
    Shanthi, Natesan
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (02) : 219 - 230
  • [25] Logistic regression analysis of conventional ultrasonography, strain elastosonography, and contrast-enhanced ultrasound characteristics for the differentiation of benign and malignant thyroid nodules
    Pang, Tiantian
    Huang, Leidan
    Deng, Yingyuan
    Wang, Tianfu
    Chen, Siping
    Gong, Xuehao
    Liu, Weixiang
    PLOS ONE, 2017, 12 (12):
  • [26] Diagnostic value of qualitative and quantitative parameters of contrast-enhanced ultrasound for differentiating differentiated thyroid carcinomas from benign nodules
    Fan, Jinfang
    Tao, Lingling
    Zhan, Weiwei
    Li, Weiwei
    Kuang, Lijun
    Zhao, Yingyan
    Zhou, Wei
    FRONTIERS IN ENDOCRINOLOGY, 2024, 14
  • [27] The value of the Demetics ultrasound-assisted diagnosis system in the differential diagnosis of benign from malignant thyroid nodules and analysis of the influencing factors
    Wuping Mai
    Meijun Zhou
    Jinhua Li
    Wenhong Yi
    Sushu Li
    Ye Hu
    Jiangting Ji
    Weibo Zeng
    Bo Gao
    Hongmei Liu
    European Radiology, 2021, 31 : 7936 - 7944
  • [28] Successful Implementation of an Artificial Intelligence-Based Computer-Aided Detection System for Chest Radiography in Daily Clinical Practice
    Lee, Seungsoo
    Shin, Hyun Joo
    Kim, Sungwon
    Kim, Eun-Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (09) : 847 - 852
  • [29] The value of the Demetics ultrasound-assisted diagnosis system in the differential diagnosis of benign from malignant thyroid nodules and analysis of the influencing factors
    Mai, Wuping
    Zhou, Meijun
    Li, Jinhua
    Yi, Wenhong
    Li, Sushu
    Hu, Ye
    Ji, Jiangting
    Zeng, Weibo
    Gao, Bo
    Liu, Hongmei
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7936 - 7944
  • [30] Positive Predictive Values of Abnormality Scores From a Commercial Artificial Intelligence-Based Computer-Aided Diagnosis for Mammography
    Lee, Si Eun
    Hong, Hanpyo
    Kim, Eun-Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (04) : 343 - 350