Clinical Value of Artificial Intelligence-Based Computer-Aided Diagnosis System Versus Contrast-Enhanced Ultrasound for Differentiation of Benign From Malignant Thyroid Nodules in Different Backgrounds

被引:3
作者
Liu, Ting [1 ]
Wu, Chuang [2 ]
Wang, Guojuan [1 ]
Jia, Yingying [1 ]
Zhu, Yangyang [1 ]
Nie, Fang [1 ,3 ]
机构
[1] Lanzhou Univ, Ultrasound Med Ctr, Hosp 2, Lanzhou, Peoples R China
[2] Lanzhou Univ, Dept Magnet Resonance, Hosp 2, Lanzhou, Peoples R China
[3] Lanzhou Univ, Hosp 2, Ultrasound Med Ctr, Dept Ultrasound, Lanzhou 730000, Gansu, Peoples R China
关键词
artificial intelligence; contrast-enhanced ultrasound; thyroid nodules; HASHIMOTO THYROIDITIS; STRATIFICATION; FEATURES;
D O I
10.1002/jum.16195
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The aim of this study was to compare the value of AI-SONIC ultrasound-assisted diagnosis system versus contrast-enhanced ultrasound (CEUS) for differential diagnosis of thyroid nodules in diffuse and non-diffuse backgrounds.Methods-A total of 555 thyroid nodules with pathologically confirmed diagnosis were included in this retrospective study. The diagnostic efficacies of AI-SONIC and CEUS for differentiating benign from malignant nodules in diffuse and non-diffuse backgrounds were evaluated, with pathological diagnosis as the gold standard.Results-The agreement between AI-SONIC diagnosis and pathological diagnosis was moderate in diffuse backgrounds (kappa = 0.417) and almost perfect in non-diffuse backgrounds (kappa = 0.81). The agreement between CEUS diagnosis and pathological diagnosis was substantial in diffuse backgrounds (kappa = 0.684) and moderate in non diffuse backgrounds (kappa = 0.407). In diffuse backgrounds, AI-SONIC had slightly higher sensitivity (95.7 vs 89.4%, P = .375), but CEUS had significantly higher specificity (80.0 vs 40.0%, P = .008). In non-diffuse background, AI-SONIC had significantly higher sensitivity (96.2 vs 73.4%, P < .001), specificity (82.9 vs 71.2%, P = .007), and negative predictive value (90.3 vs 53.3%, P < .001).Conclusion-In non-diffuse backgrounds, AI-SONIC is superior to CEUS for differentiating malignant from benign thyroid nodules. In diffuse backgrounds, AI-SONIC could be useful for screening of cases to detect suspicious nodules requiring further examination by CEUS.
引用
收藏
页码:1757 / 1766
页数:10
相关论文
共 43 条
[1]   Value of differential diagnosis of contrast-enhanced ultrasound in benign and malignant thyroid nodules with microcalcification [J].
Gao, Zhixiang ;
Lu, Qin ;
Yan, Jiping .
ONCOLOGY LETTERS, 2019, 17 (05) :4545-4549
[2]   Diagnostic efficacy of the contrast-enhanced ultrasound thyroid imaging reporting and data system classification for benign and malignant thyroid nodules [J].
Yang, Yu-Ping ;
Zhang, Guo-Li ;
Zhou, Hong-Lian ;
Dai, Hai-Xia ;
Huang, Xing ;
Liu, Li-Juan ;
Xie, Jun ;
Wang, Jie-Xin ;
Li, Hua-Juan ;
Liang, Xin ;
Yuan, Qian ;
Zeng, Yan-Hao ;
Xu, Xiao-Hong .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08) :5721-5736
[3]   Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments [J].
Chang, Yongjun ;
Paul, Anjan Kumar ;
Kim, Namkug ;
Baek, Jung Hwan ;
Choi, Young Jun ;
Ha, Eun Ju ;
Lee, Kang Dae ;
Lee, Hyoung Shin ;
Shin, DaeSeock ;
Kim, Nakyoung .
MEDICAL PHYSICS, 2016, 43 (01) :554-567
[4]   Computer-aided diagnosis of malignant or benign thyroid nodes based on ultrasound images [J].
Yu, Qin ;
Jiang, Tao ;
Zhou, Aiyun ;
Zhang, Lili ;
Zhang, Cheng ;
Xu, Pan .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (07) :2891-2897
[5]   Diagnostic performance of artificial intelligence-based computer-aided diagnosis system in longitudinal and transverse ultrasonic views for differentiating thyroid nodules [J].
Zheng, Lin-Lin ;
Ma, Su-Ya ;
Zhou, Ling ;
Yu, Cong ;
Xu, Hai-Shan ;
Xu, Li-Long ;
Li, Shi-Yan .
FRONTIERS IN ENDOCRINOLOGY, 2023, 14
[6]   Usefulness of combined use of contrast-enhanced ultrasound and TI-RADS classification for the differentiation of benign from malignant lesions of thyroid nodules [J].
Zhang, Yan ;
Zhou, Ping ;
Tian, Shuang-Ming ;
Zhao, Yong-Feng ;
Li, Jia-Le ;
Li, Lan .
EUROPEAN RADIOLOGY, 2017, 27 (04) :1527-1536
[7]   The Value of Chinese Thyroid Imaging Report and Data System Combined With Contrast-Enhanced Ultrasound Scoring in Differential Diagnosis of Benign and Malignant Thyroid Nodules [J].
Cao, Haiyan ;
Fan, Qi ;
Zhuo, Shuangshuang ;
Qi, Tingyue ;
Sun, Hongguang ;
Rong, Xin ;
Xiao, Xiao ;
Zhang, Wen ;
Zhu, Linhai ;
Wang, Lei .
JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (07) :1753-1761
[8]   A Novel Interpretable Computer-Aided Diagnosis System of Thyroid Nodules on Ultrasound Based on Clinical Experience [J].
Zhang, Shijie ;
Du, Huarui ;
Jin, Zhuang ;
Zhu, Yaqiong ;
Zhang, Ying ;
Xie, Fang ;
Zhang, Mingbo ;
Tian, Xiaoqi ;
Zhang, Jue ;
Luo, Yukun .
IEEE ACCESS, 2020, 8 :53223-53231
[9]   Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules [J].
He, Yan ;
Wang, Xiao Yan ;
Hu, Qiao ;
Chen, Xue Xue ;
Ling, Bing ;
Wei, Hai Ming .
FRONTIERS IN PHARMACOLOGY, 2018, 9
[10]   Artificial intelligence assists identifying malignant versus benign liver lesions using contrast-enhanced ultrasound [J].
Hu, Hang-Tong ;
Wang, Wei ;
Chen, Li-Da ;
Ruan, Si-Min ;
Chen, Shu-Ling ;
Li, Xin ;
Lu, Ming-De ;
Xie, Xiao-Yan ;
Kuang, Ming .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 (10) :2875-2883