Utility of Central 10 Degrees Visual Field Test With Size V Stimulus in End-Stage Glaucoma

被引:0
|
作者
Hwang, Young Hoon [1 ,2 ]
机构
[1] Cent Seoul Eye Ctr, Seoul, South Korea
[2] Cent Seoul Eye Ctr, Ichon ro 224, Seoul 04427, South Korea
关键词
glaucoma; visual field; optic nerve; STANDARD AUTOMATED PERIMETRY; FREQUENCY-DOUBLING PERIMETRY; THRESHOLD; VARIABILITY; SENSITIVITY; DEFECTS;
D O I
10.1097/IJG.0000000000002315
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: In end-stage glaucoma, the central 10-degree visual field test with a size V stimulus provided useful information, including the number of points with detectable retinal sensitivity threshold values and retinal sensitivity threshold values.Purpose: The purpose of this study was to evaluate the clinical utility of the central 10-degree visual field test with a size V stimulus in end-stage glaucoma.Materials and Methods: A total of 73 eyes with end-stage glaucoma (visual field limited to a radius of <10 degrees from fixation) were included. Central 10 degrees visual field tests were performed using both size III and V stimuli. Reliability indices, test duration, number of points with detectable retinal sensitivity threshold values, and retinal sensitivity threshold values at 4 central points, 4 quadrants, and 3 clusters (papillomacular area, superior half, and inferior half) were compared between the test results using size III and V stimuli.Results: When the size V stimulus was used, the mean test duration increased from 7.8 to 13.3 minutes (P < 0.001), the mean number of test points with detectable retinal sensitivity threshold values in total area increased from 19.0 to 37.3 (P < 0.001), and the mean retinal sensitivity threshold values in total area increased from 3.9 to 9.3 dB (P < 0.001) compared with the test results with the size III stimulus. Significant increase in the visual field parameters was found in all quadrants and clusters (P < 0.001), and a greater increase was associated with better visual acuity and greater mean deviation of the visual field (P < 0.05).Conclusions: The central 10-degree visual field test with a size V stimulus provided more information than the test with a size III stimulus in end-stage glaucoma.
引用
收藏
页码:1022 / 1028
页数:7
相关论文
共 36 条
  • [21] Qualitative Evaluation of the 10-2 and 24-2 Visual Field Tests for Detecting Central Visual Field Abnormalities in Glaucoma
    Orbach, Adi
    Ang, Ghee Soon
    Camp, Andrew S.
    Welsbie, Derek S.
    Medeiros, Felipe A.
    Girkin, Christopher A.
    Fazio, Massimo A.
    Hyuk, Oh Won
    Weinreb, Robert N.
    Zangwill, Linda M.
    Zhichao Wu
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 229 : 26 - 33
  • [22] Cluster Formation for Analyses of Glaucomatous Visual Field Defects in Central 10-2 Visual Field in Normal Tension Glaucoma Eyes
    Suzumura, Hirotaka
    Yoshikawa, Keiji
    Kimura, Tairo
    Nanno, Mami
    Tsumura, Toyoaki
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 611 - 618
  • [23] Agreement Between 10-2 and 24-2C Visual Field Test Protocols for Detecting Glaucomatous Central Visual Field Defects
    Chakravarti, Tutul
    Moghadam, Mohamad
    Proudfoot, James A.
    Weinreb, Robert N.
    Bowd, Christopher
    Zangwill, Linda M.
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : E285 - E291
  • [24] Comparative Analysis of 24-2C, 24-2, and 10-2 Visual Field Tests for Detecting Mild-Stage Glaucoma With Central Visual field Defects
    Nishijima, Euido
    Fukai, Kota
    Sano, Kei
    Noro, Takahiko
    Ogawa, Shumpei
    Okude, Sachiyo
    Tatemichi, Masayuki
    Lee, Gary c.
    Iwase, Aiko
    Nakano, Tadashi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 268 : 275 - 284
  • [25] Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects
    Swanson, William H.
    Horner, Douglas G.
    Dul, Mitchell W.
    Malinovsky, Victor E.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (05):
  • [26] A Method Using Goldmann Stimulus Sizes I to V-Measured Sensitivities to Predict Lead Time Gained to Visual Field Defect Detection in Early Glaucoma
    Phu, Jack
    Khuu, Sieu K.
    Bui, Bang V.
    Kalloniatis, Michael
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [27] The 24-2 Visual Field Test Misses Central Macular Damage Confirmed by the 10-2 Visual Field Test and Optical Coherence Tomography
    Grillo, Lola M.
    Wang, Diane L.
    Ramachandran, Rithambara
    Ehrlich, Alyssa C.
    De Moraes, Carlos Gustavo
    Ritch, Robert
    Hood, Donald C.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (02):
  • [28] Deep learning model to predict visual field in central 10° from optical coherence tomography measurement in glaucoma
    Hashimoto, Yohei
    Asaoka, Ryo
    Kiwaki, Taichi
    Sugiura, Hiroki
    Asano, Shotaro
    Murata, Hiroshi
    Fujino, Yuri
    Matsuura, Masato
    Miki, Atsuya
    Mori, Kazuhiko
    Ikeda, Yoko
    Kanamoto, Takashi
    Yamagami, Junkichi
    Inoue, Kenji
    Tanito, Masaki
    Yamanishi, Kenji
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (04) : 507 - 513
  • [29] Optical Coherence Tomography Angiography Macular Vascular Density Measurements and the Central 10-2 Visual Field in Glaucoma
    Penteado, Rafaella C.
    Zangwill, Linda M.
    Daga, Fabio B.
    Saunders, Luke J.
    Manalastas, Patricia I. C.
    Shoji, Takuhei
    Akagi, Tadamichi
    Christopher, Mark
    Yarmohammadi, Adeleh
    Moghimi, Sasan
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2018, 27 (06) : 481 - 489
  • [30] Modifying the Conventional Visual Field Test Pattern to Improve the Detection of Early Glaucomatous Defects in the Central 10°
    Ehrlich, Alyssa C.
    Raza, Ali S.
    Ritch, Robert
    Hood, Donald C.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (06):