Evaluation of fluid responsiveness with dynamic superior vena cava collapsibility index in mechanically ventilated patients

被引:3
作者
Li, Yaru [1 ]
Jiang, Luyang [1 ]
Wang, Lu [1 ]
Dou, Dou [1 ]
Feng, Yi [1 ]
机构
[1] Peking Univ, Peoples Hosp, Dept Anesthesiol, 11 Xi Zhi Men South St, Beijing 100044, Peoples R China
关键词
Fluid responsiveness FR; Transesophageal echocardiography TEE; Superior vena cava SVC; Stroke volume variation SVV; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; ECHOCARDIOGRAPHY; RECOMMENDATIONS; GUIDELINES; UPDATE; ADULTS; VOLUME;
D O I
10.1186/s13741-023-00298-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background This study aimed to evaluate the predictive accuracy of the superior vena cava collapsibility index measured by transesophageal echocardiography and compare the index with stroke volume variation measured by FloTrac (TM)/Vigileo (TM) in mechanically ventilated patients. Methods In the prospective study, a total of 60 patients were enrolled for elective general surgery under mechanical ventilation, where all patients received 10 ml/kg of Ringer's lactate. Five kinds of related data were recorded before and after the fluid challenge, including the superior vena cava collapsibility index (SVC-CI), the ratio of E/e', cardiac index (CI), stroke volume variation (SVV), and central venous pressure (CVP). Based on the collected data after the fluid challenge, we classified the patients as responders (FR group) if their CI increased by at least 15% and the rest were non-responders (NR). Results Twenty-five of 52 (48%) of the patients were responders, and 27 were non-responders (52%). The SVC-CI was higher in the responders (41.90 +/- 11.48 vs 28.92 +/- 9.05%, P < 0.01). SVC-CI was significantly correlated with Delta CI (FloTrac) (r = 0.568, P < 0.01). The area under the ROC curve (AUROC) of SVC-CI was 0.838 (95% CI 0.728 similar to 0.947, P < 0.01) with the optimal cutoff value of 39.4% (sensitivity 64%, specificity 92.6%). And there was no significant difference in E/e' between the two groups (P > 0.05). The best cutoff value for SVV was 12.5% (sensitivity 40%, specificity 89%) with the AUROC of 0.68 (95% CI 0.53 similar to 0.826, P < 0.05). Conclusions The SVC-CI and SVV can predict fluid responsiveness effectively in mechanically ventilated patients. And SVC-CI is superior in predicting fluid responsiveness compared with SVV. The E/e' ratio and CVP cannot predict FR effectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Correlation between transhepatic and subcostal inferior vena cava ultrasonographic images for evaluating fluid responsiveness after cardiac surgery
    Manzur-Sandoval, Daniel
    Arteaga-Cardenas, Gerardo
    Gopar-Nieto, Rodrigo
    Lazcano-Diaz, Emmanuel
    Rojas-Velasco, Gustavo
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (09) : 2586 - 2591
  • [22] The relationship between superior vena cava diameter and collapsibility and central venous pressure
    Cowie, B. S.
    Kluger, R.
    Rex, S.
    Missant, C.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (03) : 357 - 360
  • [23] Assessment of end-tidal carbon dioxide and vena cava collapsibility in volume responsiveness in spontaneously breathing patients
    Guney Pinar, S.
    Pekdemir, M.
    Ozturan, I. U.
    Dogan, N. O.
    Yaka, E.
    Yilmaz, S.
    Karadas, A.
    Ferek Emir, D.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2022, 117 (01) : 34 - 40
  • [24] A Two Parameters for the Evaluation of Hypovolemia in Patients with Septic Shock: Inferior Vena Cava Collapsibility Index (IVCCI) Delta Cardiac Output
    Kacar, Cem Kivilcum
    Uzundere, Osman
    Yektas, Abdulkadir
    MEDICAL SCIENCE MONITOR, 2019, 25 : 8105 - 8111
  • [25] Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?
    Airapetian, Norair
    Maizel, Julien
    Alyamani, Ola
    Mahjoub, Yazine
    Lorne, Emmanuel
    Levrard, Melanie
    Ammenouche, Nacim
    Seydi, Aziz
    Tinturier, Francois
    Lobjoie, Eric
    Dupont, Herve
    Slama, Michel
    CRITICAL CARE, 2015, 19
  • [26] Preoperative evaluation of inferior venae cava collapsibility index to predict post induction hypotension under general anaesthesia
    Fanai, Annie Lalliankimi
    Sharma, Arti
    Pathania, Jyoti
    Sethi, Arvind
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2024, 32 (01): : 21 - 32
  • [27] Performance of a 25% Inferior Vena Cava Collapsibility in Detecting Fluid Responsiveness When Assessed by Novice Versus Expert Physician Sonologists
    Corl, Keith A.
    Azab, Nader
    Nayeemuddin, Mohammed
    Schick, Alexandra
    Lopardo, Thomas
    Zeba, Fatima
    Phillips, Gary
    Baird, Grayson
    Merchant, Roland C.
    Levy, Mitchell M.
    Blaivas, Michael
    Abbasi, Adeel
    JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (12) : 1520 - 1528
  • [28] Correlation of preoperative inferior vena cava diameter and inferior vena cava collapsibility index with preoperative fasting status, patient demography and general anaesthesia associated hypotension: A prospective, observational study
    Agarwal, Jyotsna
    Panjiar, Pratibha
    Khanuja, Samiksha
    Annapureddy, Sai Krishna R.
    Saloda, Ali
    Butt, Kharat M.
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (18) : 320 - 327
  • [29] Inferior vena cava collapsibility index as a predictor of hypotension after induction of general anesthesia in hypertensive patients
    Fathy, Mohamed Metwaly
    Wahdan, Rehab A.
    Salah, Amal Abdul Azeem
    Elnakera, Abeer M.
    BMC ANESTHESIOLOGY, 2023, 23 (01)
  • [30] Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
    Byon, H. -J.
    Lim, C. -W.
    Lee, J. -H.
    Park, Y. -H.
    Kim, H. -S.
    Kim, C. -S.
    Kim, J. -T.