A review of recent advances in carbon dioxide absorption-stripping by employing a gas-liquid hollow fiber polymeric membrane contactor

被引:15
作者
Kianfar, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Islamic Azad Univ, Dept Chem, Sousangerd Branch, Sousangerd, Iran
[2] Istanbul Medeniyet Univ, Dept Mech Engn, Istanbul, Turkey
[3] Islamic Azad Univ, Dept Chem Engn, Arak Branch, Arak, Iran
[4] Islamic Azad Univ, Gachsaran Branch, Young Researchers & Elite Club, Gachsaran, Iran
关键词
Hollow fiber membrane; Acid gases; Membrane contactor; Polymeric membrane; Absorption/stripping; MIXED MATRIX MEMBRANES; CO2; ABSORPTION; IONIC LIQUID; NONDISPERSIVE ABSORPTION; TRANSPORT PROPERTIES; COMPOSITE MEMBRANES; SHARP BOUNDS; PERFORMANCE; SEPARATION; OPTIMIZATION;
D O I
10.1007/s00289-022-04626-z
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Membrane contactors using microporous membranes for acid gas removal have been extensively reviewed and discussed. The microporous membrane acts as a fixed interface between the gas and the liquid phase without dispersing one phase into another that offers a flexible modular and energy-efficient device. The gas absorption process can offer a high selectivity and a high driving force for transport even at low concentrations. Using hollow fiber, gas-liquid membrane contactors are a promising alternative to conventional gas absorption systems for acid gas capture from gas streams. Important aspects of membrane contactor as an efficient energy device for acid gas removal including liquid absorbents, membrane characteristics, combination of membrane and absorbent, mass transfer, membrane modules, model development, advantages and disadvantages were critically discussed. In addition, current status and future potential in research and development of gas-liquid membrane contactors for acid gas removal were also briefly discussed. The most essential factors of membrane contactors for CO2 absorption/stripping are also discussed, including the hydrophilicity and hydrophobicity of the absorption materials in the membranes, as well as other models published in the literature. The benefits and drawbacks of gas-liquid contactor membranes in CO2 absorption/stripping are also investigated, and the technique is compared to existing separation methods. The technology's present condition and potential directions are explored, as well as some recommendations for further study in order to commercialize.
引用
收藏
页码:11469 / 11505
页数:37
相关论文
共 50 条
  • [31] Removal of carbon dioxide from pressurized landfill gas by physical absorbents using a hollow fiber membrane contactor
    Li, Yifu
    Wang, Li'ao
    Jin, Pengrui
    Song, Xue
    Zhan, Xinyuan
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2017, 121 : 149 - 161
  • [32] Mass Transfer Simulation of Carbon Dioxide Absorption in a Hollow-Fiber Membrane Contactor
    Shirazian, S.
    Ashrafizadeh, S. N.
    SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (04) : 515 - 524
  • [33] Gas-liquid membrane contactors for acid gas removal: recent advances and future challenges
    Zhang, Yuan
    Wang, Rong
    CURRENT OPINION IN CHEMICAL ENGINEERING, 2013, 2 (02) : 255 - 262
  • [34] Preparation of a novel dual-layer polyvinylidene fluoride hollow fiber composite membrane with hydrophobic inner layer for carbon dioxide absorption in a membrane contactor
    Chen, Zezhi
    Shen, Qi
    Gong, Huijuan
    Du, Mengfan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 248
  • [35] Polysulfone porous hollow fiber membranes for ethylene-ethane separation in gas-liquid membrane contactor
    Ovcharova, Anna
    Vasilevsky, Vladimir
    Borisov, Ilya
    Bazhenov, Stepan
    Volkov, Alexey
    Bildyukevich, Alexandr
    Volkov, Vladimir
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 183 : 162 - 172
  • [36] Long-term stability of PVDF-SiO2-HDTMS composite hollow fiber membrane for carbon dioxide absorption in gas-liquid contacting process
    Pang, Honglei
    Qiu, Yayu
    Sheng, Weipeng
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [37] Simulation of Carbon Dioxide Absorption in a Hollow Fiber Membrane Contactor Under Non-Isothermal Conditions
    Jin, Youkang
    Wang, Lei
    Bi, Jinpeng
    Zhao, Wei
    Zhang, Hui
    Lv, Yuexia
    Chen, Xi
    MEMBRANES, 2025, 15 (03)
  • [38] MASS TRANSFER ANALYSIS AND SIMULATION OF A HOLLOW FIBER GAS-LIQUID MEMBRANE CONTACTOR
    Keshavarz, P.
    Fathikalajahi, J.
    Ayatollahi, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2008, 32 (B6): : 585 - 599
  • [39] Carbon dioxide stripping through water by porous PVDF/montmorillonite hollow fiber mixed matrix membranes in a membrane contactor
    DashtArzhandi, M. Rezaei
    Ismail, A. F.
    Matsuura, T.
    RSC ADVANCES, 2015, 5 (28): : 21916 - 21924
  • [40] Porous polyethersulfone hollow fiber membrane in gas-liquid contacting processes
    Bakeri, Gh
    Ismail, A. F.
    Rahimnejad, M.
    Matsuura, T.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (07) : 1381 - 1390