Experimental study on the seismic performance of clay brick masonry wall strengthened with stainless steel strips

被引:16
作者
Jin, Yu-Hang [1 ,2 ]
Zhou, Zhong-Yi [1 ,2 ]
Bao, Ben-Lin [3 ]
Wang, Hai-Yun [1 ,2 ]
Wang, Tao [1 ,2 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150080, Peoples R China
[2] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
[3] China Railway Fifth Survey & Design Inst Grp Corp, Beijing 102600, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 69卷
关键词
Stainless steel strip; Masonry strengthened; Seismic performance; Bearing capacity calculation formula; Restoring force model; REINFORCEMENT; BEHAVIOR;
D O I
10.1016/j.jobe.2023.106076
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Strengthening the existing masonry structures with stainless steel strips is a new strengthening approach, which combines the advantages of compatible-to-masonry, chemically stable, durable, effective retrofitting, and low impact on the existing masonry structure. The horizontal and vertical stainless strips was anchored into the masonry wall with the angle steel and steel pipe to improve its in-plane tensile strength and ductility. To study the seismic performance of brick masonry walls strengthened with stainless steel strips, one masonry wall and five stainless steel strip strengthened masonry wall specimens with different packing modes and grid spacings were tested under low frequency cyclic loading. The experimental results show that the proposed strengthening approach can efficiently improve the seismic performance of the existing masonry structures, such as the load bearing capacity, ductility, stiffness, and energy dissipation capacity. The failure modes and damage evolution law of all the specimens were compared and analyzed. The load bearing capacity and hysteretic curves of the specimen were calculated using the proposed calculation formula and restoring force model, respectively. The calculated results are consistent with the test results, which provides an appropriate theoretical support and design basis for the masonry reinforcement design with stainless steel strips.
引用
收藏
页数:18
相关论文
共 25 条
[1]  
[Anonymous], 2015, JGJ/T101:2015
[2]  
[Anonymous], 2009, 702009 JGTT
[3]  
[Anonymous], 2014, 507022011 GB
[4]  
[Anonymous], 2003, 500112010 GB
[5]  
[Anonymous], 2011, GB/T 50129-2011
[6]   Stainless steel strip - A proposed shear reinforcement for masonry wall panels [J].
Borri, Antonio ;
Corradi, Marco ;
Castori, Giulio ;
Molinari, Alessio .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 211 :594-604
[7]   Experimental Evaluation of Full-Scale URM Buildings Strengthened Using Surface-Mounted Steel Bands [J].
Choudhury, Thainswemong ;
Kaushik, Hemant B. .
JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (02)
[8]   A review of the use of stainless steel for masonry repair and reinforcement [J].
Corradi, Marco ;
Di Schino, Andrea ;
Borri, Antonio ;
Rufini, Riccardo .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 181 :335-346
[9]   The Reticulatus method for shear strengthening of fair-faced masonry [J].
Corradi, Marco ;
Borri, Antonio ;
Castori, Giulio ;
Sisti, Romina .
BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (12) :3547-3571
[10]   In -plane seismic behavior of autoclaved aerated concrete block masonry walls retrofitted with high ductile fiber -reinforced concrete [J].
Deng, Mingke ;
Zhang, Wei ;
Yang, Shuo .
ENGINEERING STRUCTURES, 2020, 219