Novel configuration of dual-temperature condensation and dual-temperature evaporation high-temperature heat pump system: Carbon footprint, energy consumption, and financial assessment

被引:34
作者
Dai, Baomin [1 ]
Wang, Qi [1 ]
Liu, Shengchun [1 ]
Wang, Dabiao [2 ]
Yu, Liqi [1 ]
Li, Xinhai [1 ]
Wang, Yuanyuan [1 ]
机构
[1] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
[2] Fuzhou Univ, Natl Engn Res Ctr Chem Fertilizer Catalyst NERC CF, Sch Chem Engn, Fujian 350002, Peoples R China
关键词
High-temperature heat pump; Ejector; Dual-temperature condensation; Dual-temperature evaporation; Temperature matching; Waste heat recovery; CO2 REFRIGERATION CYCLE; LOW-GWP REFRIGERANTS; PERFORMANCE ANALYSIS; WORKING; R1234ZE(Z);
D O I
10.1016/j.enconman.2023.117360
中图分类号
O414.1 [热力学];
学科分类号
摘要
To achieve the goal of carbon neutrality for the application of industrial heating by recovery waste heat, the concept of dual-temperature condensation and dual-temperature evaporation is proposed for the hightemperature heat pump (HTHP) by introducing the techniques of ejector and two-stage compression. The energy, exergy, emission, and economic models are developed and optimized for the two new proposed systems. Then, the energy consumption, CO2 emissions and cost (LCC) during the whole life cycle are compared with five existing heat pumps and four traditional boilers. The highest coefficient of performance (COP) of heat pump (HP) can be got when intermediate water temperature on the heat sink side is optimum. The new proposed systems have better performances than the other five HTHPs. During the rated working condition, discharge temperature decreases by the use of dual-temperature condensation and dual-temperature evaporation HP with an ejector (EjDCDE). The optimal COP of Ej-DCDE-2 is 4.25, which is 11.55% and 1.43% higher than dual-temperature condensation and single-temperature evaporation HP and Ej-DCDE-1, respectively. The exergy destruction of Ej-DCDE-2 is reduced by 27.88% compared with basic heat pump (Base). Moreover, Ej-DCDE-2 has the lowest primary energy consumption of 14.62 ktoe, 22.19% and 25.09% lower than Base and oil-fired boiler during the total working period, respectively. In general, HTHPs have lower carbon dioxide, gaseous and particular pollutant emissions compared with boilers, especially Ej-DCDE-2. Finally, Ej-DCDE-2 has the minimum LCC, which is 14.67% and 11.75% less than Base and coal-fired boiler. Ej-DCDE-2 shows the most potential advantages of all the heating solutions and is recommended to replace traditional boilers for industrial heating.
引用
收藏
页数:25
相关论文
共 63 条
  • [1] A review on energy saving strategies in industrial sector
    Abdelaziz, E. A.
    Saidur, R.
    Mekhilef, S.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) : 150 - 168
  • [2] [Anonymous], 2012, 25892008 GB
  • [3] High temperature heat pumps: Market overview, state of the art, research status, refrigerants, and application potentials
    Arpagaus, Cordin
    Bless, Frederic
    Uhlmann, Michael
    Schiffmann, Jurg
    Bertsch, Stefan S.
    [J]. ENERGY, 2018, 152 : 985 - 1010
  • [4] Multi-temperature heat pumps: A literature review
    Arpagaus, Cordin
    Bless, Frederic
    Schiffmann, Jurg
    Bertsch, Stefan S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 437 - 465
  • [5] Theoretical Performance Analysis of an Ejector Enhanced High-Temperature Heat Pump with Dual-Pressure Condensation and Evaporation
    Bai Tao
    Liu Ye
    Yan Gang
    Yu Jianlin
    [J]. JOURNAL OF THERMAL SCIENCE, 2022, 31 (05) : 1367 - 1379
  • [6] Thermodynamic assessment of a condenser outlet split ejector-based high temperature heat pump cycle using various low GWP refrigerants
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    [J]. ENERGY, 2019, 179 : 850 - 862
  • [7] The development of a hydrocarbon high temperature heat pump for waste heat recovery
    Bamigbetan, O.
    Eikevik, T. M.
    Neksa, P.
    Bantle, M.
    Schlemminger, C.
    [J]. ENERGY, 2019, 173 : 1141 - 1153
  • [8] Bejan A., 1995, Thermal design and optimization
  • [9] Multi-criteria (thermodynamic, economic and environmental) analysis of possible design options for residential heating split systems working with low GWP refrigerants
    Botticella, F.
    de Rossi, F.
    Mauro, A. W.
    Vanoli, G. P.
    Viscito, L.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 87 : 131 - 153
  • [10] The fluorinated olefin R-1234ze(Z) as a high-temperature heat pumping refrigerant
    Brown, J. Steven
    Zilio, Claudio
    Cavallini, Alberto
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (06): : 1412 - 1422