Outcomes of Ceramic- On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study

被引:6
作者
Alshammari, Malek O. [1 ]
de Petrillo, Gianni [1 ]
Epure, Laura M. [1 ]
Huk, Olga L. [1 ]
Zukor, David J. [1 ]
Antoniou, John [1 ]
机构
[1] McGill Univ, Jewish Gen Hosp, Dept Orthopaed, 3755 Chem Cote St Catherine, Montreal, PQ, Canada
关键词
total hip arthroplasty; ceramic-on-ceramic; BIOLOX delta; hip squeaking; ceramic composite hip prosthesis; fourth generation of ceramics; FEMORAL-HEAD SIZE; SQUEAKING; ALUMINA; IMPINGEMENT; DISLOCATION; FRACTURES; MIGRATION; DEBRIS; NOISE; WEAR;
D O I
10.1016/j.arth.2023.04.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although the fourth generation of ceramics has demonstrated excellent clinical results 5 to 6 years postoperatively, concerns over ceramic fracture and squeaking persist and longer-term follow-up (minimum 10 years) studies are warranted. Our study aimed to evaluate the minimum 10-year clinical outcomes and bearing-specific complications of ceramic-on-ceramic (CoC) total hip arthroplasties. Methods: We retrospectively evaluated all patients who underwent primary delta CoC total hip arthroplasty in our institution between January 2004 and February 2013. Demographics, surgical techniques, complications, patient-reported outcomes, and radiographic outcomes were collected and analyzed. For continuous variables, the comparison between groups was conducted using a one-way analysis of variance. Of all 235 patients included in the study, 70.5% were women (190 hips). The mean follow-up period was 12 years (range, 10 to 18). The femoral head sizes of 28- mm, 32 mm, and 36 mm were used in 50, 26, and 197 cases, respectively. Mean acetabular inclination and anteversion angles were 39.2 +/- 7.1 degrees and 14.9 +/- 3.5 degrees. Results: There were 5 hips revised at a mean 4.6 years (range, 0.1 to 7.1). One revision was squeaking-related. Squeaking was also reported by 8 other patients, but did not require revision. Other reasons for revision were early infection in 2 cases, stem loosening in 1 case, and stem fracture in 2 cases. The survival analysis for any causes for revision as an endpoint was 96.7% (95% confidence interval 0.313%2.57%). Conclusion: We report excellent mean 12-year follow-up results regarding the complications and survivorship of the fourth generation CoC bearings. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S146 / S151
页数:6
相关论文
共 44 条
[1]   Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement [J].
Al-Hajjar, Mazen ;
Leslie, Ian J. ;
Tipper, Joanne ;
Williams, Sophie ;
Fisher, John ;
Jennings, Louise M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (02) :263-268
[2]   Midterm Outcomes of the Recently FDA Approved Ceramic on Ceramic Bearing in Total Hip Arthroplasty Patients Under 65 Years of Age [J].
Aoude, Ahmed A. ;
Antoniou, John ;
Epure, Laura M. ;
Huk, Olga L. ;
Zukor, David J. ;
Tanzer, Michael .
JOURNAL OF ARTHROPLASTY, 2015, 30 (08) :1388-1392
[3]   Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty [J].
Blumenfeld, Thomas J. ;
Politi, Joel ;
Croker, Sean ;
O'Dell, Tammy ;
Hamilton, William .
ARTHROPLASTY TODAY, 2022, 13 :130-135
[4]   Wear debris from two different alumina-on-alumina total hip arthroplasties [J].
Böhler, M ;
Mochida, Y ;
Bauer, TW ;
Plenk, H ;
Salzer, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06) :901-909
[5]   Primary Total Hip Arthroplasty With Fourth-Generation Ceramic-on-Ceramic: Analysis of Complications in 939 Consecutive Cases Followed for 2-10 Years [J].
Buttaro, Martin A. ;
Zanotti, Gerardo ;
Comba, Fernando M. ;
Piccaluga, Francisco .
JOURNAL OF ARTHROPLASTY, 2017, 32 (02) :480-486
[6]   Squeaking in a Delta Ceramic-on-Ceramic Uncemented Total Hip Arthroplasty [J].
Buttaro, Martin A. ;
Zanotti, Gerardo ;
Comba, Fernando M. ;
Piccaluga, Francisco .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1257-1259
[7]  
Campbell Joshua, 2017, Arthroplast Today, V3, P83, DOI 10.1016/j.artd.2016.11.006
[8]   A Rare Case of Adverse Reaction to Metal Debris in a Ceramic-on-Ceramic Total Hip Replacement [J].
Cannella, Adriano ;
Greco, Tommaso ;
Polichetti, Chiara ;
De Martino, Ivan ;
Mascio, Antonio ;
Maccauro, Giulio ;
Perisano, Carlo .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (03)
[9]   Mixed ceramic combinations in primary total hip arthroplasty achieved reassuring mid-to-longterm outcomes [J].
Castagnini, Francesco ;
Bordini, Barbara ;
Biondi, Federico ;
Cosentino, Monica ;
Stea, Susanna ;
Traina, Francesco .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2020, 31 (07)
[10]   Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life [J].
Chatelet, Jean-Christophe ;
Fessy, Michel-Henri ;
Saffarini, Mo ;
Machenaud, Alain ;
Jacquot, Laurent .
JOURNAL OF ARTHROPLASTY, 2021, 36 (05) :1678-1687