Experimental investigation of FPS inter-storey isolation control for assembled steel structure with high aspect ratio

被引:8
作者
Zhang, Chunwei [1 ,2 ]
Duan, Cunkun [2 ]
Sun, Li [3 ]
机构
[1] Shenyang Univ Technol, Multidisciplinary Ctr Infrastruct Engn, Shenyang 110870, Peoples R China
[2] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
[3] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Peoples R China
基金
中国国家自然科学基金;
关键词
High-rise structure; Inter-storey isolation; Friction pendulum system; Shaking table test; EEMD analysis; FRICTION PENDULUM SYSTEM; BASE-ISOLATION; TEFLON BEARINGS; PERFORMANCE; BUILDINGS; DESIGN;
D O I
10.1016/j.istruc.2023.04.077
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A comprehensive experimental investigation of high-rise structure employing the friction pendulum system (FPS) in accordance with inter-storey isolation control strategy are presented in this paper. A test assembled steel structure is constructed in accordance with the third generation Benchmark model. Three types of FPS systems with varied slideway radius are designed and manufactured. Through shaking table tests, seismic performance of the FPS inter-storey isolation (FPS-I) strategy for structure with a high aspect ratio was examined. The test cases involve eight isolation layer locations, six ground motions, and four types of peak ground accelerations (PGA). The test results demonstrate that using FPS-I scheme to control vibration of assembled steel structure with an aspect ratio greater than four is feasible and effective. Furthermore, when the FPS is installed on the 6th to 8th floors of the structure, the top floor's acceleration attenuation rate is approaching 67%, leaving the controlled structure's response is only one third of the uncontrolled structure. The dynamic characteristics of the controlled structure are impacted by the isolation layer's location, which is indicated in the changing of the ratio of the modal participation mass coefficients. By regulating the contribution factor of each mode, the FPS-I scheme effectively lessens the structural high-order mode's contribution to structural response.
引用
收藏
页码:550 / 567
页数:18
相关论文
共 43 条
[1]   Seismic reliability of structures equipped with LIR-DCFP bearings in terms of superstructure ductility and isolator displacement [J].
Auad, Gaspar ;
Castaldo, Paolo ;
Almazan, Jose L. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (13) :3171-3214
[2]   Direct displacement design of tall cross laminated timber platform buildings with inter-story isolation [J].
Bolvardi, Vahab ;
Pei, Shiling ;
van de Lindt, John W. ;
Dolan, James D. .
ENGINEERING STRUCTURES, 2018, 167 :740-749
[3]   A high performance hybrid passive base-isolated system [J].
Cao, Liyuan ;
Li, Chunxiang .
STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (03)
[4]  
Castaldo P, 2022, ING SISMICA-ITAL, V39
[5]   TEFLON BEARINGS IN BASE ISOLATION .2. MODELING [J].
CONSTANTINOU, M ;
MOKHA, A ;
REINHORN, A .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (02) :455-474
[6]  
Duan C, 2022, ADV CIV ENG, V2022, P1
[7]  
Fenz D.M., 2008, Tech. Rep. MCEER-08-0018
[8]  
GB, 2010, GB50011-2010
[9]   Optimum friction pendulum system for near-fault motions [J].
Jangid, RS .
ENGINEERING STRUCTURES, 2005, 27 (03) :349-359
[10]   Base isolation for near-fault motions [J].
Jangid, RS ;
Kelly, JM .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (05) :691-707