Analysis of Blood Flow in the Macula and Optic Nerve Head in Healthy Young Volunteers Using Laser Speckle Flowgraphy

被引:0
作者
Bajka, Anahita [1 ]
Foa, Nastasia [1 ]
Sidhu, Sophia [2 ]
Rejdak, Magdalena [1 ]
Said, Sadiq [1 ]
Wiest, Maximilian Robert Justus [1 ]
Hamann, Timothy [1 ]
Blaser, Frank [1 ]
Zweifel, Sandrine Anne [1 ,3 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Ophthalmol, Zurich, Switzerland
[2] Univ San Diego, Fac Med, San Diego, CA USA
[3] Univ Spital Zurich, Augenklin, Frauenklin Str 24, CH-8091 Zurich, Switzerland
关键词
laser speckle flowgraphy; retina; bloodflow; noninvasive; retinal imaging; AUTOREGULATION; RETINA; AGE;
D O I
10.1055/a-2026-0924
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To assess optic nerve head (ONH) and macular blood flow in young healthy volunteers using laser speckle flowgraphy (LSFG). Methods This is a prospective single-center study conducted at the Department of Ophthalmology, University Hospital Zurich from May to November 2021. Young, healthy men aged >= 18 years without ocular or systemic diseases were included. A corrected visual acuity (VA) of 0.0 logMAR or better in both eyes and an intraocular pressure (IOP) of 21 mmHg or lower were required for inclusion. Subjects exceeding a spherical equivalent (SE) of +/- 6 diopters (dpt) were excluded. Blood flow in the macula and the ONH was recorded using the Nidek LSFG RetFlow device (Nidek Company, Ltd., Hirioshicho, Japan). Laser power was set to 0.5 Millivolts (mV). Mean blur rate (MBR) was recorded as a parameter for blood flow. MBR is a calculated parameter that represents relative blood flow velocity correlated with the real anatomical blood flow rate. Colored heat maps of the recorded retinal area were generated automatically by the RetFlow device. Results Final analyses included 83 eyes of 43 male volunteers. Mean age was 21.9 years (SD +/- 1.5, range: 20 to 29). Mean corrected VA was - 0.1 logMAR (SD +/- 0.05, range: - 0.2 to 0.0), mean IOP was 15.4 mmHg (SD +/- 2.5, range: 8.5 to 18.5), and mean SE was - 0.3 dpt (SD +/- 1.2, range: - 5.0 to 1.2). Mean ONH MBR was 37.44 (SD +/- 7.9, range: 22.5 to 53.5) and mean macular MBR was 27.8 (SD +/- 9.7, range: 6.4 to 57.7). Pearson's Test showed a strong correlation between macular and papillary blood flow (p < 0.05, coefficient: 0.647). Conclusion This study provides both ONH and macular blood flow data in a healthy young male population, showing a strong correlation between ONH and macular blood flow in the examined eyes. Further investigations are required to assess the validity of MBR as a parameter for the combined evaluation of retinal blood flow at the macula and ONH in healthy volunteers and patients with various diseases.
引用
收藏
页码:608 / 612
页数:5
相关论文
共 23 条
  • [1] Age- and Sex-Dependency of Laser Speckle Flowgraphy Measurements of Optic Nerve Vessel Microcirculation
    Aizawa, Naoko
    Kunikata, Hiroshi
    Nitta, Fumihiko
    Shiga, Yukihiro
    Omodaka, Kazuko
    Tsuda, Satoru
    Nakazawa, Toru
    [J]. PLOS ONE, 2016, 11 (02):
  • [2] Retinal Blood Flow Velocity in Patients with Age-Related Macular Degeneration
    Burgansky-Eliash, Zvia
    Barash, Hila
    Nelson, Darin
    Grinvald, Amiram
    Sorkin, Alina
    Loewenstein, Anat
    Barak, Adiel
    [J]. CURRENT EYE RESEARCH, 2014, 39 (03) : 304 - 311
  • [3] Assessment of choroidal blood flow using laser speckle flowgraphy
    Calzetti, Giacomo
    Fondi, Klemens
    Bata, Ahmed M.
    Luft, Nikolaus
    Wozniak, Piotr A.
    Witkowska, Katarzyna J.
    Bolz, Matthias
    Popa-Cherecheanu, Alina
    Werkmeister, Rene M.
    Schmidl, Doreen
    Garhoefer, Gerhard
    Schmetterer, Leopold
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (12) : 1679 - 1683
  • [4] Relationship between retinal blood flow and arterial oxygen
    Cheng, Richard W.
    Yusof, Firdaus
    Tsui, Edmund
    Jong, Monica
    Duffin, James
    Flanagan, John G.
    Fisher, Joseph A.
    Hudson, Chris
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2016, 594 (03): : 625 - 640
  • [5] Groh MJM, 1996, OPHTHALMOLOGY, V103, P529
  • [6] Retinal blood flow dysregulation precedes neural retinal dysfunction in type 2 diabetic mice
    Hanaguri, Junya
    Yokota, Harumasa
    Watanabe, Masahisa
    Yamagami, Satoru
    Kushiyama, Akifumi
    Kuo, Lih
    Nagaoka, Taiji
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Blood flow distribution and the endothelial surface layer in the diabetic retina
    Harris, Norman R.
    Leskova, Wendy
    Kaur, Gaganpreet
    Eshaq, Randa S.
    Carter, Patsy R.
    [J]. BIORHEOLOGY, 2019, 56 (2-3) : 181 - 189
  • [8] Changes in pulse waveforms in response to intraocular pressure elevation determined by laser speckle flowgraphy in healthy subjects
    Iwase, Chie
    Iwase, Takeshi
    Tomita, Ryo
    Akahori, Tomohiko
    Yamamoto, Kentaro
    Ra, Eimei
    Terasaki, Hiroko
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [9] What ocular and systemic variables affect choroidal circulation in healthy eyes
    Iwase, Takeshi
    Yamamoto, Kentaro
    Kobayashi, Misato
    Ra, Eimei
    Murotani, Kenta
    Terasaki, Hiroko
    [J]. MEDICINE, 2016, 95 (43)
  • [10] Correlation between laser speckle flowgraphy and optical coherence tomography angiography measurements in normal and glaucomatous eyes
    Kohmoto, Ryohsuke
    Sugiyama, Tetsuya
    Ueki, Mari
    Kojima, Shota
    Maeda, Michiko
    Nemoto, Emika
    Tokuoka, Satoru
    Ikeda, Tsunehiko
    [J]. CLINICAL OPHTHALMOLOGY, 2019, 13 : 1799 - 1805