Preclinical Evaluation of a Non-Customized Modular Inner Branched Stent Graft for Total Endovascular Aortic Arch Repair in a Porcine Model

被引:0
作者
Rong, Dan [1 ]
Zhang, Hongpeng [1 ]
Guo, Wei [1 ]
Liu, Feng [1 ]
Ge, Yangyang [1 ]
Zhu, Yating [1 ]
Zhang, Minhong [1 ]
Xu, Yongle [1 ]
Jia, Xin [1 ]
Ma Xiaohui [1 ]
Xiong, Jiang [1 ]
Wang, Lijun [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Vasc & Endovasc Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
aortic arch disease; non-customized; endovascular repair; inner branched stent-graft; porcine model; ANEURYSM;
D O I
10.1177/15266028221090445
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The aim of this study was to evaluate the feasibility and safety of a non-customized modular inner branched stent graft for total endovascular aortic arch repair in a porcine model. Methods: The modular inner branched stent graft system with a split main body design included 1 proximal main component, 1 distal main component, and 1 branched covered stent. The gutter in the proximal main component was sealed with sutured membrane. Fatigue testing was performed to evaluate the durability of the stent graft. Fifteen pigs were used in this study. In each pig, a stent graft was delivered and deployed to the aortic arch through the femoral arterial access and right carotid arterial access. Angiography and computed tomography angiography were used to evaluate the morphological features before euthanasia. After euthanasia, the implanted device, surrounding tissue, and major organs were harvested for gross and histological examination. Results: There were no collapses and no stent graft fractures detected after fatigue testing. The technical success rate was 14/15, and the incidence of major adverse cardiovascular events was 2/15. Angiography performed at the end of follow-up revealed no endoleaks and no device migration. Histological examination demonstrated excellent biocompatibility of the stent graft. Conclusions: The non-customized modular inner branched stent graft system is safe and feasible for the endovascular reconstruction of the aortic arch in a porcine model.
引用
收藏
页码:628 / 636
页数:9
相关论文
共 15 条
  • [1] Current results of open total arch replacement versus hybrid thoracic endovascular aortic repair for aortic arch aneurysm: A meta-analysis of comparative studies
    Benedetto, Umberto
    Melina, Giovanni
    Angeloni, Emiliano
    Codispoti, Massimiliano
    Sinatra, Riccardo
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) : 305 - 306
  • [2] Clough RE, 2013, ANN CARDIOTHORAC SUR, V2, P300, DOI 10.3978/j.issn.2225-319X.2013.05.10
  • [3] Current options and recommendations for the treatment of thoracic aortic pathologies involving the aortic arch: an expert consensus document of the European Association for Cardio-Thoracic surgery (EACTS) and the European Society for Vascular Surgery (ESVS)
    Czerny, Martin
    Schmidli, Jurg
    Adler, Sabine
    van den Berg, Jos C.
    Bertoglio, Luca
    Carrel, Thierry
    Chiesa, Roberto
    Clough, Rachel E.
    Eberle, Balthasar
    Etz, Christian
    Grabenwoeger, Martin
    Haulon, Stephan
    Jakob, Heinz
    Kari, Fabian A.
    Mestres, Carlos A.
    Pacini, Davide
    Resch, Timothy
    Rylski, Bartosz
    Schoenhoff, Florian
    Shrestha, Malakh
    von Tengg-Kobligk, Hendrik
    Tsagakis, Konstantinos
    Wyss, Thomas R.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (01) : 133 - 162
  • [4] Orthotopic branched endovascular aortic arch repair in patients who cannot undergo classical surgery
    Czerny, Martin
    Rylski, Bartosz
    Morlock, Julia
    Schroefel, Holger
    Beyersdorf, Friedhelm
    Saint Lebes, Bertrand
    Meyrignac, Olivier
    Mokrane, Fatima
    Lescan, Mario
    Schlensak, Christian
    Hazenberg, Constatijn
    Bloemert-Tuin, Trijntje
    Braithwaite, Sue
    van Herwaarden, Joost
    Rousseau, Herve
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (05) : 1007 - 1012
  • [5] Global experience with an inner branched arch endograft
    Haulon, Stephan
    Greenberg, Roy K.
    Spear, Rafaelle
    Eagleton, Matt
    Abraham, Cherrie
    Lioupis, Christos
    Verhoeven, Eric
    Ivancev, Krassi
    Koelbel, Tilo
    Stanley, Brendan
    Resch, Timothy
    Desgranges, Pascal
    Maurel, Blandine
    Roeder, Blayne
    Chuter, Timothy
    Mastracci, Tara
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04) : 1709 - 1716
  • [6] Hongku K, 2016, J CARDIOVASC SURG, V57, P784
  • [7] Inoue K, 1999, CIRCULATION, V100, P316
  • [8] Thoracic Endovascular Repair for Aortic Arch Pathologies with Surgeon Modified Fenestrated Stent Grafts: A Multicentre Retrospective Study
    Li, Xiaoye
    Li, Wei
    Dai, Xiangchen
    Li, Wei
    Zhang, Jinlong
    Wang, Zanxin
    Tong, Yuanhao
    Chen, Yonghui
    Zhang, Lei
    Song, Chao
    Meng, Qingyou
    Wei, Minxin
    Liu, Zhao
    Lu, Qingsheng
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (05) : 758 - 766
  • [9] Maurel B, 2016, J CARDIOVASC SURG, V57, P686
  • [10] Editor's Choice - Subsequent Results for Arch Aneurysm Repair with Inner Branched Endografts
    Spear, R.
    Haulon, S.
    Ohki, T.
    Tsilimparis, N.
    Kanaoka, Y.
    Milne, C. P. E.
    Debus, S.
    Takizawa, R.
    Koelbe, T.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 51 (03) : 380 - 385