Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions

被引:25
作者
Fink, Nicola [1 ,2 ]
Zsarnoczay, Emese [1 ,3 ]
Schoepf, U. Joseph [1 ,7 ]
Griffith III, Joseph P. P. [1 ]
Wolf, Elias V. [1 ,4 ]
O'Doherty, Jim [1 ,5 ]
Suranyi, Pal [1 ]
Baruah, Dhiraj [1 ]
Kabakus, Ismail M. [1 ]
Ricke, Jens [2 ]
Varga-Szemes, Akos [1 ]
Emrich, Tilman [1 ,4 ,6 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC USA
[2] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[3] Semmelweis Univ, Heart & Vasc Ctr, Cardiovasc Imaging Res Grp, Budapest, Hungary
[4] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Mainz, Germany
[5] Siemens Med Solut, Malvern, PA USA
[6] German Ctr Cardiovasc Res, Partner Site Rhine Main, Mainz, Germany
[7] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Ashley River Tower,25 Courtenay Dr,MSC 226, Charleston, SC 29425 USA
关键词
coronary artery calcium scoring; virtual noniodine reconstruction; photon counting detector computed tomography; virtual monoenergetic imaging; iterative reconstruction; COMPUTED-TOMOGRAPHY; PROGNOSTIC VALUE; QUANTIFICATION; CALCIFICATION; ANGIOGRAPHY; FEASIBILITY; EVENTS;
D O I
10.1097/RLI.0000000000000959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the impact of virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on the accuracy of coronary artery calcium scoring (CACS) using a virtual noniodine (VNI) reconstruction algorithm on a first-generation, clinical, photon counting detector computed tomography system. Materials and Methods: Coronary artery calcium scoring was evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by using 2 extension rings (small: 300 x 200 mm, medium: 350 x 250 mm, large: 400 x 300 mm) and in patients (n = 61; final analyses only in patients with coronary calcifications [n = 34; 65.4 +/- 10.0 years; 73.5% male]), who underwent nonenhanced and contrast-enhanced, electrocardiogram-gated, cardiac computed tomography on a photon counting detector system. Phantom and patient data were reconstructed using a VNI reconstruction algorithm at different VMI (55-80 keV) and QIR (strength 1-4) levels (CACS(VNI)). True noncontrast (TNC) scans at 70 keV and QIR "off " were used as reference for phantom and patient studies (CACS(TNC)). Results: In vitro and in vivo CACS(VNI) showed strong correlation (r > 0.9, P < 0.001 for all) and excellent agreement (intraclass correlation coefficient > 0.9 for all) with CACSTNC at all investigatedVMI andQIR levels. Phantom and patient CACS(VNI) significantly increased with decreasing keV levels (in vitro: from 475.2 +/- 26.3 at 80 keV up to 652.5 +/- 42.2 at 55 keV; in vivo: from 142.5 [7.4/737.7] at 80 keVup to 248.1 [31.2/1144] at 55 keV; P < 0.001 for all), resulting in an overestimation of CACS(VNI) at 55 keV compared with CACS(TNC) at 70 keV in some cases (in vitro: 625.8 +/- 24.4; in vivo: 225.4 [35.1/959.7]). In vitro CACS increased with rising QIR at low keV. In vivo scores were significantly higher at QIR 1 compared with QIR 4 only at 60 and 80 keV(60 keV: 220.3 [29.6-1060] vs 219.5 [23.7/1048]; 80 keV: 152.0 [12.0/735.6] vs 142.5 [7.4/737.7]; P < 0.001). CACS(VNI) was closest to CACS(TNC) at 60 keV, QIR 2 (+0.1%) in the small; 55 keV, QIR 1 (+/- 0%) in the medium; 55 keV, QIR 4 (-0.1%) in the large phantom; and at 60 keV, QIR 1 (-2.3%) in patients. Conclusions: Virtual monoenergetic imaging reconstructions have a significant impact on CACSVNI. The effects of different QIR levels are less consistent and seem to depend on several individual conditions, which should be further investigated.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 46 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom [J].
Allmendinger, Thomas ;
Nowak, Tristan ;
Flohr, Thomas ;
Klotz, Ernst ;
Hagenauer, Junia ;
Alkadhi, Hatem ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2022, 57 (06) :399-405
[3]  
Arnett DK, 2019, J AM COLL CARDIOL, V74, pE177, DOI 10.1016/j.jacc.2019.03.010
[4]   Predictive value of coronary calcifications for future cardiac events in asymptomatic individuals [J].
Becker, Alexander ;
Leber, Alexander ;
Becker, Christoph ;
Knez, Andreas .
AMERICAN HEART JOURNAL, 2008, 155 (01) :154-160
[5]   First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography [J].
Boccalini, Sara ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Diaw, Adja ;
Varasteh, Mohammad ;
Rodesch, Pierre-Antoine ;
Villien, Marjorie ;
Sigovan, Monica ;
Dessouky, Riham ;
Coulon, Philippe ;
Yagil, Yoad ;
Lahoud, Elias ;
Erhard, Klaus ;
Rioufol, Gilles ;
Finet, Gerard ;
Bonnefoy-Cudraz, Eric ;
Bergerot, Cyrille ;
Boussel, Loic ;
Douek, Philippe C. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (04) :212-221
[6]   Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT [J].
Decker, Josua A. ;
Bette, Stefanie ;
Lubina, Nora ;
Rippel, Katharina ;
Braun, Franziska ;
Risch, Franka ;
Wollny, Claudia ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
[7]   Coronary calcium as a predictor of coronary events in four racial or ethnic groups [J].
Detrano, Robert ;
Guerci, Alan D. ;
Carr, J. Jeffrey ;
Bild, Diane E. ;
Burke, Gregory ;
Folsom, Aaron R. ;
Liu, Kiang ;
Shea, Steven ;
Szklo, Moyses ;
Bluemke, David A. ;
O'Leary, Daniel H. ;
Tracy, Russell ;
Watson, Karol ;
Wong, Nathan D. ;
Kronmal, Richard A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (13) :1336-1345
[8]   Use of cardiac CT and calcium scoring for detecting coronary plaque: implications on prognosis and patient management [J].
Divakaran, S. ;
Cheezum, M. K. ;
Hulten, E. A. ;
Bittencourt, M. S. ;
Silverman, M. G. ;
Nasir, K. ;
Blankstein, R. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1046)
[9]   Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans [J].
Eberhard, Matthias ;
Mergen, Victor ;
Higashigaito, Kai ;
Allmendinger, Thomas ;
Manka, Robert ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Euler, Andre ;
Alkadhi, Hatem .
DIAGNOSTICS, 2021, 11 (09)
[10]   Reduced Iodinated Contrast Media Administration in Coronary CT Angiography on a Clinical Photon-Counting Detector CT System A Phantom Study Using a Dynamic Circulation Model [J].
Emrich, Tilman ;
O'Doherty, Jim ;
Schoepf, U. Joseph ;
Suranyi, Pal ;
Aquino, Gilberto ;
Kloeckner, Roman ;
Halfmann, Moritz C. ;
Allmendinger, Thomas ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Varga-Szemes, Akos .
INVESTIGATIVE RADIOLOGY, 2023, 58 (02) :148-155