Monitoring chloride-induced corrosion in metallic and reinforced/prestressed concrete structures using piezo sensors-based electro-mechanical impedance technique: A review

被引:31
作者
Morwal, Tarun [1 ]
Bansal, Tushar [1 ]
Azam, Ammar [1 ]
Talakokula, Visalakshi [2 ]
机构
[1] Sharda Univ, Dept Civil Engn, Greater Noida 201310, India
[2] Mahindra Univ, Dept Civil Engn, Hyderabad 500043, India
关键词
Metallic structure; Reinforced concrete structures; Prestressed concrete structures; Chloride-induced corrosion; Electro-mechanical impedance technique; Structural health monitoring; Piezo sensors; REINFORCED-CONCRETE; PRESTRESSED CONCRETE; GUIDED-WAVES; STEEL; IDENTIFICATION; TRANSDUCERS; PROGRESSION; CARBONATION; DIAGNOSIS; BARS;
D O I
10.1016/j.measurement.2023.113102
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In metallic, reinforced concrete (RC) and prestressed concrete (PC) structures, corrosion is one of the main problems which adversely affects its service life. Therefore, structural health monitoring (SHM) is essential for performance evaluation and safety maintenance to prevent and reduce engineering accidents. In the field of SHM, corrosion monitoring using piezo sensor-based electro-mechanical impedance (EMI) technique has become a research hotspot. In this paper, the research progress of corrosion monitoring using piezo sensor via EMI technique in metallic, RC, and PC structures during the last two decades was comprehensively reviewed. The basic principle of the EMI technique, development of piezo sensor configurations, and the quantification of corrosion using various statistical methods were discussed. In addition to that, the numerical simulation of corrosion sensor modelling in metallic and RC structures using the EMI technique and the literature studies on qualitative and quantitative analysis performed by the various researchers were also discussed. This review paper will aid the researchers, academicians, and scientists who are venturing into this research area in conducting proper experiments related to chloride-induced corrosion either in metallic/RC/PC structures by choosing appropriate sensor configurations, placement, acquisition, correlation, and calibration.
引用
收藏
页数:14
相关论文
共 73 条
[41]   Investigation of novel embedded piezoelectric ultrasonic transducers on crack and corrosion monitoring of steel bar [J].
Liu, Peng ;
Hu, Yan ;
Chen, Ying ;
Geng, Bo ;
Xu, Dongyu .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 235
[42]   Investigation on novel embedded piezoelectric ultrasonic transducers for corrosion monitoring of reinforced concrete [J].
Liu, Peng ;
Hu, Yan ;
Geng, Bo ;
Xu, Dongyu .
SMART MATERIALS AND STRUCTURES, 2019, 28 (11)
[43]   Corrosion monitoring of reinforced concrete beam using embedded cement-based piezoelectric sensor [J].
Lu, Youyuan ;
Zhang, Jinrui ;
Li, Zongjin ;
Dong, Biqin .
MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (21) :1265-1276
[44]   A new guided wave-based technique for corrosion monitoring in reinforced concrete [J].
Miller, Tri H. ;
Kundu, Tribikram ;
Huang, Jiaqiang ;
Grill, Julian Y. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2013, 12 (01) :35-47
[45]   Corrosion of reinforcing steel in simulated concrete pore solutions -: Effect of carbonation and chloride content [J].
Moreno, M ;
Morris, W ;
Alvarez, MG ;
Duffó, GS .
CORROSION SCIENCE, 2004, 46 (11) :2681-2699
[46]   Electromechanical impedance method of fiber-reinforced plastic adhesive joints in corrosive environment using a reusable piezoelectric device [J].
Na, Sam ;
Tawie, Rudy ;
Lee, Haeng-Ki .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2012, 23 (07) :737-747
[47]   Corrosion in cracked and uncracked concrete - influence of crack width, concrete quality and crack reopening [J].
Otieno, M. B. ;
Alexander, M. G. ;
Beushausen, H. -D. .
MAGAZINE OF CONCRETE RESEARCH, 2010, 62 (06) :393-404
[48]   MFC-based structural health monitoring using a miniaturized impedance measuring chip for corrosion detection [J].
Park, Seunghee ;
Grisso, Benjamin L. ;
Inman, Daniel J. ;
Yun, Chung-Bang .
RESEARCH IN NONDESTRUCTIVE EVALUATION, 2007, 18 (02) :139-150
[49]   Quantitative Corrosion Monitoring Using Wireless Electromechanical Impedance Measurements [J].
Park, Seunghee ;
Park, Sun-Kyu .
RESEARCH IN NONDESTRUCTIVE EVALUATION, 2010, 21 (03) :184-192
[50]   Pipeline corrosion assessment using piezo-sensors in reusable non-bonded configuration [J].
Raju, Jayalakshmi ;
Bhalla, Suresh ;
Visalakshi, Talakokula .
NDT & E INTERNATIONAL, 2020, 111