Monitoring chloride-induced corrosion in metallic and reinforced/prestressed concrete structures using piezo sensors-based electro-mechanical impedance technique: A review

被引:31
作者
Morwal, Tarun [1 ]
Bansal, Tushar [1 ]
Azam, Ammar [1 ]
Talakokula, Visalakshi [2 ]
机构
[1] Sharda Univ, Dept Civil Engn, Greater Noida 201310, India
[2] Mahindra Univ, Dept Civil Engn, Hyderabad 500043, India
关键词
Metallic structure; Reinforced concrete structures; Prestressed concrete structures; Chloride-induced corrosion; Electro-mechanical impedance technique; Structural health monitoring; Piezo sensors; REINFORCED-CONCRETE; PRESTRESSED CONCRETE; GUIDED-WAVES; STEEL; IDENTIFICATION; TRANSDUCERS; PROGRESSION; CARBONATION; DIAGNOSIS; BARS;
D O I
10.1016/j.measurement.2023.113102
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In metallic, reinforced concrete (RC) and prestressed concrete (PC) structures, corrosion is one of the main problems which adversely affects its service life. Therefore, structural health monitoring (SHM) is essential for performance evaluation and safety maintenance to prevent and reduce engineering accidents. In the field of SHM, corrosion monitoring using piezo sensor-based electro-mechanical impedance (EMI) technique has become a research hotspot. In this paper, the research progress of corrosion monitoring using piezo sensor via EMI technique in metallic, RC, and PC structures during the last two decades was comprehensively reviewed. The basic principle of the EMI technique, development of piezo sensor configurations, and the quantification of corrosion using various statistical methods were discussed. In addition to that, the numerical simulation of corrosion sensor modelling in metallic and RC structures using the EMI technique and the literature studies on qualitative and quantitative analysis performed by the various researchers were also discussed. This review paper will aid the researchers, academicians, and scientists who are venturing into this research area in conducting proper experiments related to chloride-induced corrosion either in metallic/RC/PC structures by choosing appropriate sensor configurations, placement, acquisition, correlation, and calibration.
引用
收藏
页数:14
相关论文
共 73 条
[1]   Evaluation of damage progression in concrete structures due to reinforcing steel corrosion using acoustic emission monitoring [J].
Abouhussien A.A. ;
Hassan A.A.A. .
Journal of Civil Structural Health Monitoring, 2015, 5 (05) :751-765
[2]   A novel approach for non-destructive EMI-based corrosion monitoring of concrete-embedded reinforcements using multi-orientation piezoelectric sensors [J].
Ahmadi, Jamal ;
Feirahi, Mohammad Hamed ;
Farahmand-Tabar, Salar ;
Fard, Amir Hossein Keshvari .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 273
[3]   Corrosion damage identification for reinforced concrete beam using embedded piezoelectric transducer: Numerical simulation [J].
Ai, Demi ;
Du, Lixun ;
Li, Hedong ;
Zhu, Hongping .
MEASUREMENT, 2022, 192
[4]   An effective electromechanical impedance technique for steel structural health monitoring [J].
Ai, Demi ;
Zhu, Hongping ;
Luo, Hui ;
Yang, Jingwen .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 73 :97-104
[5]   COVER CRACKING AS A FUNCTION OF BAR CORROSION .1. EXPERIMENTAL TEST [J].
ANDRADE, C ;
ALONSO, C ;
MOLINA, FJ .
MATERIALS AND STRUCTURES, 1993, 26 (162) :453-464
[6]   Piezoelectric sensor-based damage progression in concrete through serial/parallel multi-sensing technique [J].
Balamonica, K. ;
Saravanan, T. Jothi ;
Priya, C. Bharathi ;
Gopalakrishnan, N. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2020, 19 (02) :339-356
[7]  
Bansal T., 2020, RILEM BOOKSERIES, P555, DOI [10.1007/978-981-15-2806-462, DOI 10.1007/978-981-15-2806-462]
[8]  
Bansal T., REBAR CORROSION ASSE
[9]  
Bansal T., 2020, RILEM Bookseries, P723, DOI [10.1007/978-981-15-2806-4_80, DOI 10.1007/978-981-15-2806-4_80]
[10]  
Bansal T., 2018, MODEL BASED CORROSIO