Continuous monitoring of acute myocardial infarction with a 3-Lead ECG system

被引:6
作者
Hernandez, Alfonso Aranda [1 ,2 ]
Bonizzi, Pietro [1 ]
Peeters, Ralf [1 ]
Karel, Joel [1 ]
机构
[1] Maastricht Univ, Dept Adv Comp Sci, Maastricht, Netherlands
[2] Medtron Bakken Res Ctr, Maastricht, Netherlands
关键词
Acute myocardial infarction diagnosis; ECG; Continuous Monitoring; Distribution Parameters; Deep Learning; RNN; WAVELET ANALYSIS; THROMBOLYTIC THERAPY; ST-SEGMENT; ISCHEMIA; CLASSIFICATION; TIME; IDENTIFICATION; LOCALIZATION; ALGORITHM; ENTROPY;
D O I
10.1016/j.bspc.2022.104041
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: A growing body of research focuses on the automated diagnosis of acute myocardial infarction (AMI) using electrocardiogram (ECG) recordings. Several methods rely on differences between the ECG at baseline (no AMI) and during AMI condition. However, this approach may not sufficiently account for the progress of AMI, and it can underestimate the effect of false positives in a continuous monitoring setting. This in turn may hinder the adoption of automated methods for AMI diagnosis in the clinical practice. In this study, we propose a new automated method for the dynamic assessment of AMI condition. This method accounts for the dynamic nature underlying AMI events and the need for a low false positives incidence. Using a reduced 3-lead ECG system, we developed a novel set of parameters able to capture changes over time in the distribution properties of ECG -derived features. These parameters are used to train and validate a deep learning model in order to perform dynamic assessment of AMI condition. Conclusion: Results suggest that the proposed method is able to capture the dynamic evolution of AMI with a false positive rate below 1%. Significance: Thanks to the reduced number of leads, the proposed method could be used to assess AMI condition in long-term, remote and home monitoring, and intensive care unit (ICU) environments.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Acute myocardial infarction system of care in the third world
    Dharma, S.
    Juzar, D. A.
    Firdaus, I.
    Soerianata, S.
    Wardeh, A. J.
    Jukema, J. W.
    NETHERLANDS HEART JOURNAL, 2012, 20 (06) : 254 - 259
  • [22] Comparison of Heart Rate Feedback from Dry-Electrode ECG, 3-Lead ECG, and Pulse Oximetry during Newborn Resuscitation
    Rettedal, Siren
    Eilevstjonn, Joar
    Kibsgaard, Amalie
    Kvaloy, Jan Terje
    Ersdal, Hege
    CHILDREN-BASEL, 2021, 8 (12):
  • [23] Detection of myocardial infarction in 12 lead ECG using support vector machine
    Dohare, Ashok Kumar
    Kumar, Vinod
    Kumar, Ritesh
    APPLIED SOFT COMPUTING, 2018, 64 : 138 - 147
  • [24] Classification of myocardial infarction with multi-lead ECG signals and deep CNN
    Baloglu, Ulas Baran
    Talo, Muhammed
    Yildirim, Ozal
    Tan, Ru San
    Acharya, U. Rajendra
    PATTERN RECOGNITION LETTERS, 2019, 122 : 23 - 30
  • [25] EARLY RECURRENT ST SEGMENT ELEVATION DURING CONTINUOUS ECG MONITORING OF MYOCARDIAL-INFARCTION PATIENTS UNDERGOING THROMBOLYSIS
    DISSMANN, R
    JERECZEK, M
    SCHRODER, R
    PINKWART, L
    VOLLER, H
    BEHRENS, S
    ANDRESEN, D
    LINDERER, T
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 (06): : 414 - 422
  • [26] Correlation between ECG and myocardial perfusion after mechanical reperfusion of acute myocardial infarction
    Tousek, P
    Krupicka, J
    Orban, M
    Firschke, C
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 107 (01) : 107 - 111
  • [27] PORTABLE, REAL-TIME, 12-LEAD ECG MONITORING SYSTEM
    Tseng, Yi-Li
    Shi, Yo-Zong
    Jaw, Fu-Shan
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (04) : 305 - 312
  • [28] Diagnostic accuracy of a novel method for detection of acute transmural myocardial ischemia based upon a self-applicable 3-lead configuration
    El Haddad, Milad
    Vervloet, Delphine
    Taeymans, Yves
    De Buyzere, Marc
    Bove, Thierry
    Stroobandt, Roland
    Duytschaever, Mattias
    Mahnivuo, Jaakko
    Gheeraert, Peter
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (02) : 192 - 201
  • [29] Incomplete ECG expression of acute true posterior myocardial infarction, owing to an antecedent anterior infarction
    Madias, JE
    Win, M
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (02) : 189 - 193
  • [30] A Wearable 1-Lead Necklace ECG for Continuous Heart Rate Monitoring
    Iskandar, Aulia A.
    Kolla, Reiner
    Schilling, Klaus
    Voelker, Wolfram
    2016 IEEE 18TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2016, : 345 - 348