Longitudinal Assessment of Retinal Nerve Fiber Layer and Ganglion Cell Complex Thicknesses in Patients With Large Optic Disc Cups and Normal Intraocular Pressure and Visual Fields

被引:2
作者
Kang, Eun Jin [1 ]
Jin, Sang Wook [1 ,2 ]
机构
[1] Dong A Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
[2] Dong A Univ, Coll Med, Dept Ophthalmol, 32 Daesingongwon Ro, Busan 49201, South Korea
关键词
large disc cupping; retinal nerve fiber layer; ganglion cell complex; Intraocular pressure; CUP/DISC RATIO; GLAUCOMA; PREVALENCE;
D O I
10.1097/IJG.0000000000002253
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Pr & eacute;cis: The thicknesses of the circumpapillary retinal nerve fiber layer (cpRNFL) and ganglion cell complex (GCC) did not change during 5 years in physiological large disc cupping. Purpose: We evaluated longitudinal changes in the thicknesses of the cpRNFL and GCC in large disc cupping with a normal intraocular pressure (IOP) (<21 mm Hg) and visual field. Methods: This retrospective, consecutive case series study included 269 eyes of 269 patients with large disc cupping and normal IOP. We analyzed patient demographics, IOP, central corneal thickness, vertical cup-to-disc ratios using color fundus photography, the thicknesses of the cpRNFL and GCC using RTVue-100, and mean deviation using visual field examinations. Results: The differences in IOP, vertical cup-to-disc ratios, and mean deviation between the baseline and each follow-up visit were not statistically significant. The baseline average and mean average at 60 months follow-up of the cpRNFL thickness were 106.5 +/- 8.5 and 105.1 +/- 9.3 mu m, respectively; differences between the baseline and each follow-up visit were not statistically significant. The baseline average and mean average at 60 months follow-up of the GCC thickness were 82.8 +/- 9. and 81.5 +/- 9.2 mu m, respectively; differences between baseline and each follow-up visit were not statistically significant. Conclusions: The thicknesses of the cpRNFL and GCC did not change in well-maintained optic nerve head findings with normal IOP and visual field during a 5-year follow-up period. Optical coherence tomography evaluations of the thicknesses of the cpRNFL and GCC help accurately diagnose physiological optic disc cupping.
引用
收藏
页码:869 / 873
页数:5
相关论文
共 50 条
  • [21] Retinal nerve fiber layer and ganglion cell complex thickness analysis in patients having relative afferent pupillary defect
    Mishra, Aradhna
    Ashraf, Mohammad
    Zaka-Ur-Rab, Simi
    Khan, Nida
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (12) : 4337 - 4342
  • [22] Effect of intraocular pressure lowering on the capillary density of optic nerve head and retinal nerve fiber layer in patients with glaucoma
    de Paula, Alessandro
    Perdicchi, Andrea
    Di Tizio, Federico
    Fragiotta, Serena
    Scuderi, Gianluca
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 3003 - 3009
  • [23] Retinal nerve fiber layer and ganglion cell complex thicknesses measured with spectral-domain optical coherence tomography in eyes with no light perception due to nonglaucomatous optic neuropathy
    Miki, Atsuya
    Endo, Takao
    Morimoto, Takeshi
    Matsushita, Kenji
    Fujikado, Takashi
    Nishida, Kohji
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (04) : 230 - 235
  • [24] Retinal nerve fiber layer and ganglion cell complex thicknesses measured with spectral-domain optical coherence tomography in eyes with no light perception due to nonglaucomatous optic neuropathy
    Atsuya Miki
    Takao Endo
    Takeshi Morimoto
    Kenji Matsushita
    Takashi Fujikado
    Kohji Nishida
    [J]. Japanese Journal of Ophthalmology, 2015, 59 : 230 - 235
  • [25] A small disc size, a big challenge: effect of optic disc size on the correlation between peripapillary choroidal thickness, peripapillary retinal nerve fiber layer, and ganglion cell layer
    Un, Yasemin
    Alpogan, Oksan
    Bolac, Ruveyde
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [26] Differences in Optic Nerve Head, Retinal Nerve Fiber Layer, and Ganglion Cell Complex Parameters Between Caucasian and Chinese Subjects
    Chansangpetch, Sunee
    Huang, Guofu
    Coh, Paul
    Oldenburg, Catherine
    Amoozgar, Behzad
    He, Mingguang
    Lin, Shan C.
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (04) : 350 - 356
  • [27] LONGITUDINAL CHANGES IN THICKNESSES OF THE MACULA, GANGLION CELL-INNER PLEXIFORM LAYER, AND RETINAL NERVE FIBER LAYER AFTER VITRECTOMY A 12-Month Observational Study
    Lim, Hyung-Bin
    Lee, Min-Woo
    Kwak, Baek-Soo
    Jo, Young-Joon
    Kim, Jung-Yeul
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (01): : 155 - 162
  • [28] Repeatability of retinal nerve fiber layer and ganglion cell complex measurements with spectral-domain optical coherence tomography in normal and glaucomatous eyes
    Abd Elfatah, Hatem F.
    Ziko, Othman A.
    Elghropy, Osama M.
    Ashour, Doaa M.
    [J]. JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2022, 115 (01) : 23 - 28
  • [29] Quantitative analysis of the retinal nerve fiber layer, ganglion cell layer and optic disc parameters by the swept source optical coherence tomography in patients with migraine and patients with tension-type headache
    Yener, Arif Ulku
    Korucu, Osman
    [J]. ACTA NEUROLOGICA BELGICA, 2019, 119 (04) : 541 - 548
  • [30] A Diagnostic Calculator for Detecting Glaucoma on the Basis of Retinal Nerve Fiber Layer, Optic Disc, and Retinal Ganglion Cell Analysis by Optical Coherence Tomography
    Manuel Larros, Jose
    Moreno-Montanes, Javier
    Maria Martinez-de-la-Casa, Jose
    Polo, Vicente
    Velazquez-Villoria, Alvaro
    Berrozpe, Clara
    Garcia-Granero, Marta
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (11) : 6788 - 6795