Cyclic behavior of a slit damper proposed for precast concrete beam-column connections

被引:5
作者
Rodriguez-Moreno, Vladimir [1 ]
Guerrero, Hector [1 ]
Escobar, J. Alberto [1 ]
Teran-Gilmore, Amador [2 ]
机构
[1] UNAM, Inst Engn, Coyoacan, Mexico
[2] Univ Autonoma Metropolitana, Mexico City, Mexico
关键词
Slit damper; Ductility; Energy dissipation; Cyclic tests; Fatigue tests; SEISMIC PERFORMANCE; STEEL; ENERGY; FRAMES; TESTS; PLATE; BRACE;
D O I
10.1016/j.engstruct.2023.116745
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Since the 2017 Puebla-Morelos Earthquake, interest in limiting damage to structural components has exponentially increased in Mexico. Consequently, the use of energy dissipation devices has received renewed attention. Following that line, this paper studies an attractive solution, which is a slit damper proposed as a passive energy dissipation device for, but not limited to, precast beam-column connections. Slit dampers have been studied for their cost-effectiveness and ease of application. They present stable hysteretic behavior and dissipate substantial amounts of energy under cyclic loading while maintaining less ductile elements essentially elastic. The structural behavior of the proposed device was evaluated theoretically, followed by experimental verification. Quasi-static incremental and constant-amplitude cyclic tests were conducted on eight specimens, with two of them having non-uniform struts. Test results are presented and discussed, emphasizing ductility and energy dissipation capacity. The proposed damper showed stable hysteretic behavior and adequate seismic performance. Using non-uniform struts significantly increased the damper's deformation capacity and fatigue performance, which is desirable for seismic zones where long-duration earthquakes are expected, such as in Mexico City. Numerical modeling techniques were also validated with finite element analyses. It was shown that the proposed damper's hysteretic response could be accurately predicted using the combined non-linear isotropic and kinematic hardening model.
引用
收藏
页数:19
相关论文
共 35 条
[1]  
ABAQUS, 2011, Analysis user's manual 6.11
[2]  
[Anonymous], 2017, ASCE/SEI 41-17)
[3]   Introducing and numerical study of a new brace-type slit damper [J].
Askariani, Seyed Saeed ;
Garivani, Sadegh .
STRUCTURES, 2020, 27 :702-717
[4]   Application of slit link beam in eccentrically braced frames [J].
Askariani, Seyed Saeed ;
Garivani, Sadegh ;
Aghakouchak, Ali Akbar .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170
[5]   Modified Low-Cycle Fatigue Estimation Using Machine Learning for Radius-Cut Coke-Shaped Metallic Damper Subjected to Cyclic Loading [J].
Bae, Jaehoon ;
Lee, Chang-Hwan ;
Park, Minjae ;
Alemayehu, Robel Wondimu ;
Ryu, Jaeho ;
Ju, Young K. .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (06) :1849-1858
[6]  
Bergman D.M., 1987, Report no. UMCE87-10
[7]   Experimental study of steel slit damper for passive energy dissipation [J].
Chan, Ricky W. K. ;
Albermani, Fafis .
ENGINEERING STRUCTURES, 2008, 30 (04) :1058-1066
[8]  
Chang K.C., 1993, EARTHQ SPECTRA, V9, P371, DOI DOI 10.1193/1.1585721
[9]  
Chopra A.K., 2011, Dynamics of Structures: Theory and Applications to Earthquake Engineering, DOI DOI 10.1193/1.2720354
[10]  
Clark P., 1999, P 69 ANN CONVENTION