Movable typing of full-lumen personalized Vein-Chips to model cerebral venous sinus thrombosis

被引:4
作者
Zhao, Yunduo Charles [1 ,2 ,3 ]
Zhang, Yingqi [1 ,2 ,3 ]
Nasser, Arian [1 ,3 ]
Hong, Tianbo [1 ]
Wang, Zihao [1 ,3 ]
Sun, Allan [1 ,2 ,3 ,4 ]
Moldovan, Laura [1 ,2 ,4 ]
Edwards, Leon S. [5 ,6 ,7 ]
Passam, Freda [2 ,3 ,8 ,9 ]
Butcher, Ken S. [10 ]
Ang, Timothy [11 ]
Ju, Lining Arnold [1 ,2 ,3 ,4 ]
机构
[1] Univ Sydney, Sch Biomed Engn, Darlington, NSW 2008, Australia
[2] Univ Sydney, Charles Perkins Ctr, Camperdown, NSW, Australia
[3] Univ Sydney, Univ Sydney Nano Inst Sydney Nano, Camperdown, NSW, Australia
[4] Heart Res Inst, Camperdown, NSW, Australia
[5] Gosford Hosp, Dept Neurosci, North Gosford, NSW, Australia
[6] Ingham Inst Appl Med Res, Sydney Brain Ctr, Liverpool, NSW, Australia
[7] Univ New South Wales, South Western Sydney Clin Sch, Liverpool, NSW, Australia
[8] Royal Prince Alfred Hosp, Dept Haematol, Camperdown, NSW, Australia
[9] Univ Sydney, Fac Med & Hlth, Cent Clin Sch, Camperdown, NSW, Australia
[10] Prince Wales Hosp, Prince Wales Clin Sch, Randwick, NSW, Australia
[11] Royal Prince Alfred Hosp, Dept Intervent Neuroradiol Neurol, Camperdown, NSW, Australia
来源
AGGREGATE | 2023年 / 4卷 / 06期
基金
英国医学研究理事会; 芬兰科学院;
关键词
3D printing; cerebral venous sinus thrombosis; mechanobiology; Organ on chip; platelet; Virchow's triad; MR VENOGRAPHY; BLOOD-FLOW; RISK; RECURRENCE; SCORE; CT;
D O I
10.1002/agt2.386
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cerebral venous sinus thrombosis (CVST) is a type of stroke associated with COVID-19 vaccine-induced immune thrombotic thrombocytopenia. The precise etiology of CVST often remains elusive due to the highly heterogeneous nature of its governing mechanisms, specifically, Virchow's triad that involves altered blood flow, endothelial dysfunction, and hypercoagulability, which varies substantially amongst individuals. Existing diagnostic and monitoring approaches lack the capability to reflect the combination of these patient-specific thrombotic determinants. In response to this challenge, we introduce a Vein-Chip platform that recapitulates the CVST vascular anatomy from magnetic resonance venography and the associated hemodynamic flow profile using the "Chinese Movable Type-like" soft stereolithography technique. The resultant full-lumen personalized Vein-Chips, functionalized with endothelial cells, enable in-vitro thrombosis assays that can elucidate distinct thrombogenic scenarios between normal vascular conditions and those of endothelial dysfunction. The former displayed minimal platelet aggregation and negligible fibrin deposition, while the latter presented significant fibrin extrusion from platelet aggregations. The low-cost movable typing technique further enhances the potential for commercialization and broader utilization of personalized Vein-Chips in surgical labs and at-home monitoring. Future research and development in this direction will pave the way for improved management and prevention of CVST, ultimately benefiting both patients and healthcare systems.
引用
收藏
页数:10
相关论文
共 43 条
[11]   Cerebral venous thrombosis after COVID-19 vaccines: Do we know the mechanism? [J].
de Gregorio, Cesare ;
Calcaterra, Giuseppe ;
Kounis, Nicholas G. ;
Bassareo, Pier Paolo ;
Mehta, Jawahar L. .
LANCET REGIONAL HEALTH-EUROPE, 2022, 16
[12]  
del Zoppo Gregory J, 2008, Rev Neurol Dis, V5 Suppl 1, pS12
[13]   Plain CT vs MR venography in acute cerebral venous sinus thrombosis: Triumphant dark horse [J].
Digge, Poornima ;
Prakashini, Koteshwar ;
Bharath, K., V .
INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2018, 28 (03) :280-284
[14]   Thromboinflammation Model-on-A-Chip by Whole Blood Microfluidics on Fixed Human Endothelium [J].
Dupuy, Alexander ;
Hagimola, Lejla ;
Mgaieth, Neil S. A. ;
Houlahan, Callum B. ;
Preketes-Tardiani, Renee E. ;
Coleman, Paul R. ;
Passam, Freda H. .
DIAGNOSTICS, 2021, 11 (02)
[15]   Prognosis of cerebral vein and dural sinus thrombosis - Results of the International Study on Cerebral Vein and Dural Sinus Thrombosis (ISCVT) [J].
Ferro, JM ;
Canhao, P ;
Stam, J ;
Bousser, MG ;
Barinagarrementeria, F .
STROKE, 2004, 35 (03) :664-670
[16]   Intracranial contrast-enhanced magnetic resonance venography with 6.4-fold sensitivity encoding at 1.5 and 3.0 Tesla [J].
Hu, Houchun H. ;
Haider, Clifton R. ;
Campeau, Norbert G. ;
Huston, John, III ;
Riederer, Stephen J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) :653-658
[17]   A shear gradient-activated microfluidic device for automated monitoring of whole blood haemostasis and platelet function [J].
Jain, Abhishek ;
Graveline, Amanda ;
Waterhouse, Anna ;
Vernet, Andyna ;
Flaumenhaft, Robert ;
Ingber, Donald E. .
NATURE COMMUNICATIONS, 2016, 7
[18]   Compression force sensing regulates integrin αIIbβ3 adhesive function on diabetic platelets [J].
Ju, Lining ;
McFadyen, James D. ;
Al-Daher, Saheb ;
Alwis, Imala ;
Chen, Yunfeng ;
Tonnesen, Lotte L. ;
Maiocchi, Sophie ;
Coulter, Brianna ;
Calkin, Anna C. ;
Felner, Eric, I ;
Cohen, Neale ;
Yuan, Yuping ;
Schoenwaelder, Simone M. ;
Cooper, Mark E. ;
Zhu, Cheng ;
Jackson, Shaun P. .
NATURE COMMUNICATIONS, 2018, 9
[19]   Microfluidic post method for 3-dimensional modeling of platelet-leukocyte interactions [J].
Ju, Lining Arnold ;
Kossmann, Sabine ;
Zhao, Yunduo Charles ;
Moldovan, Laura ;
Zhang, Yingqi ;
Ramasundara, Savindi De Zoysa ;
Zhou, Fangyuan ;
Lu, Hang ;
Alwis, Imala ;
Schoenwaelder, Simone M. ;
Yuan, Yuping ;
Jackson, Shaun P. .
ANALYST, 2022, 147 (06) :1222-1235
[20]   Comparison of CT venography with MR venography in cerebral sinovenous thrombosis [J].
Khandelwal, N. ;
Agarwal, Ajay ;
Kochhar, Rohit ;
Bapuraj, J. R. ;
Singh, Paramjeet ;
Prabhakar, S. ;
Suri, S. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) :1637-1643